This split-system transducer uses 10 ft cables to separate the electronics from the pipe connection points. It supports multiple output types and measuring ranges up to 100 psig for flexible installation.
This split-system transducer uses 10 ft cables to separate the electronics from the pipe connection points. It supports multiple output types and measuring ranges up to 100 psig for flexible installation.
The PWR series remote wet media pressure transducers allow remote pressure sensing capability using existing plumbing runs. With no need to run plumbing lines all the way to the transducer, the installation time and cost is greatly reduced.
Features
Optional Accessories: AA68, AA72
| Application Zone | Plant Room |
| Application | Pump and Compressor Differential Pressure | Chiller Differential Pressure Monitoring |
| Brand | Veris |
| Burst Pressure | 500 psi (34 bar) |
| Calibration Certificate | No |
| Dimension Depth | 2.4" (61 mm) |
| Dimension Height | 3.1" (78 mm) |
| Dimension Probe Length | 10' (3.1 m) |
| Dimension Width | 6.7" (170 mm) |
| Display Size | 0.6" x 1.2" (16 mm x 32 mm) |
| Display Type | None |
| Electrical Wiring | 3-wires |
| Enclosure Material | Plastic |
| Fitting Material | Stainless Steel |
| Fitting Size | 1/4" NPT |
| Fitting Type | Male |
| IP Protection | IP65 (NEMA 4) |
| LED Indicator Type | Red and Green |
| Measurement Type | Differential Pressure |
| Medium | Water |
| Model | PWRLX04S010 |
| Mounting | Panel | Remote Panel |
| Operating Current | 125 to 280 mA |
| Operating Humidity | 10 to 90% RH, non-condensing |
| Operating Temperature | 14 to 122°F (-10 to 50°C) |
| Output Specifications | 4 to 20 mA | 0 to 5 V | 0 to 10 V |
| Outputs | Analog output |
| Pressure Measurement Accuracy | Range A and B: ±1% of F.S. Range C: ±1.5% of F.S. Range D: ±2% of F.S. |
| Pressure Measurement Range | 0 to 10 psi (0 to 0.7 bar) | 0 to 20 psi (0 to 1.4 bar) | 0 to 50 psi (0 to 3.5 bar) | 0 to 100 psi (0 to 7 bar) |
| Product Certification | CE |
| Product Type | Sensor |
| Range | PWR |
| Standards EMC | EN 61000-6-1 |
| Supply Voltage AC Nominal | 24 VAC |
| Supply Voltage DC Range | 15 to 30 VDC |
| Warranty | 5 years |
| Application Zone | Plant Room |
| Application | Pump and Compressor Differential Pressure | Chiller Differential Pressure Monitoring |
| Brand | Veris |
| Burst Pressure | 500 psi (34 bar) |
| Calibration Certificate | No |
| Dimension Depth | 2.4" (61 mm) |
| Dimension Height | 3.1" (78 mm) |
| Dimension Probe Length | 10' (3.1 m) |
| Dimension Width | 6.7" (170 mm) |
| Display Size | 0.6" x 1.2" (16 mm x 32 mm) |
| Display Type | None |
| Electrical Wiring | 3-wires |
| Enclosure Material | Plastic |
| Fitting Material | Stainless Steel |
| Fitting Size | 1/4" NPT |
| Fitting Type | Male |
| IP Protection | IP65 (NEMA 4) |
| LED Indicator Type | Red and Green |
| Measurement Type | Differential Pressure |
| Medium | Water |
| Model | PWRLX04S010 |
| Mounting | Panel | Remote Panel |
| Operating Current | 125 to 280 mA |
| Operating Humidity | 10 to 90% RH, non-condensing |
| Operating Temperature | 14 to 122°F (-10 to 50°C) |
| Output Specifications | 4 to 20 mA | 0 to 5 V | 0 to 10 V |
| Outputs | Analog output |
| Pressure Measurement Accuracy | Range A and B: ±1% of F.S. Range C: ±1.5% of F.S. Range D: ±2% of F.S. |
| Pressure Measurement Range | 0 to 10 psi (0 to 0.7 bar) | 0 to 20 psi (0 to 1.4 bar) | 0 to 50 psi (0 to 3.5 bar) | 0 to 100 psi (0 to 7 bar) |
| Product Certification | CE |
| Product Type | Sensor |
| Range | PWR |
| Standards EMC | EN 61000-6-1 |
| Supply Voltage AC Nominal | 24 VAC |
| Supply Voltage DC Range | 15 to 30 VDC |
| Warranty | 5 years |