These Combustible Gas Leak Detectors are ideal for confined space applications. They can display up to 4 gasses simultaneously and have 2 selectable gas types of Methane (Natural Gas) and Propane.
These Combustible Gas Leak Detectors are ideal for confined space applications. They can display up to 4 gasses simultaneously and have 2 selectable gas types of Methane (Natural Gas) and Propane.
This instrument can be used for inert gas operations to detect combustible gases in oxygen-free environments. It can be configured for combustible gas readings in PPM, LEL as well as a variety of toxic gases and oxygen.
Features
Easy to get started
Partial List of Gasses Sensed
Applications
| LEL % | |
| Resolution | 0.1% |
| Range | 0 to 100% LEL |
| Accuracy | ±10% |
| Natural Gas | |
| Resolution | 0.1% |
| Range | 5 to 100% Gas |
| Accuracy | ±5% |
| Propane | |
| Resolution | 0.1% |
| Range | 2.2 to 100% Gas |
| Accuracy | ±5% |
| Oxygen (O2) | |
| Resolution | 0.1% |
| Range | 0 to 25% |
| Accuracy | ±0.2% or 10% (whichever is greater) |
| Carbon Monoxide (CO) | |
| Resolution | 1 ppm |
| Range | 0 to 2000 ppm |
| Accuracy | ±5 ppm or 5% (whichever is greater) |
| Hydrogen Sulfide (H2S) | |
| Resolution | 1 ppm |
| Range | 0 to 100 ppm |
| Accuracy | ±2 ppm or 5% (whichever is greater) |
| Hydrogen Cyanide (HCN) | |
| Resolution | 1 ppm |
| Range | 0 to 30 ppm |
| Accuracy | ±1 ppm or 5% (whichever is greater) |
| General Specifications | |
| Operational Temperature | -4 to 104°F (-20 to 40°C) |
| Battery Life | Alkaline: Approximately 18hrs continuous |
| Dimensions | 11.5 x 3 x 2.32" (29.2 x 7.6 x 5.9 cm) |
| Weight | 1.2 lbs (544 g) |
Click on a category to view a selection of compatible accessories with the SENSIT Gold G2 Series Combustible Gas Leak Detectors.
| LEL % | |
| Resolution | 0.1% |
| Range | 0 to 100% LEL |
| Accuracy | ±10% |
| Natural Gas | |
| Resolution | 0.1% |
| Range | 5 to 100% Gas |
| Accuracy | ±5% |
| Propane | |
| Resolution | 0.1% |
| Range | 2.2 to 100% Gas |
| Accuracy | ±5% |
| Oxygen (O2) | |
| Resolution | 0.1% |
| Range | 0 to 25% |
| Accuracy | ±0.2% or 10% (whichever is greater) |
| Carbon Monoxide (CO) | |
| Resolution | 1 ppm |
| Range | 0 to 2000 ppm |
| Accuracy | ±5 ppm or 5% (whichever is greater) |
| Hydrogen Sulfide (H2S) | |
| Resolution | 1 ppm |
| Range | 0 to 100 ppm |
| Accuracy | ±2 ppm or 5% (whichever is greater) |
| Hydrogen Cyanide (HCN) | |
| Resolution | 1 ppm |
| Range | 0 to 30 ppm |
| Accuracy | ±1 ppm or 5% (whichever is greater) |
| General Specifications | |
| Operational Temperature | -4 to 104°F (-20 to 40°C) |
| Battery Life | Alkaline: Approximately 18hrs continuous |
| Dimensions | 11.5 x 3 x 2.32" (29.2 x 7.6 x 5.9 cm) |
| Weight | 1.2 lbs (544 g) |
Click on a category to view a selection of compatible accessories with the SENSIT Gold G2 Series Combustible Gas Leak Detectors.