Megger 1012-521 DET4TC2 Four-Terminal Digital Ground Resistance Tester with ETK50C Earth Test Kit

Model: 1012-521 | UPC: 5036175240373

Megger 1012-521 DET4TC2 Four-Terminal Digital Ground Resistance Tester with ETK50C Earth Test Kit

Model: 1012-521 | UPC: 5036175240373

A four-terminal ground/earth resistance tester kit combining the DET4TC2 instrument with the ETK50C accessory reel set, enabling 2-, 3-, and 4-pole testing, stakeless and Attached Rod Technique (ART) modes, and soil resistivity surveys in one robust system.

A four-terminal ground/earth resistance tester kit combining the DET4TC2 instrument with the ETK50C accessory reel set, enabling 2-, 3-, and 4-pole testing, stakeless and Attached Rod Technique (ART) modes, and soil resistivity surveys in one robust system.

Your Price $2900.00 USD
Availability 2 to 3 Weeks
Quantity

Megger 1012-521 Offers

Designed to negate the need for a shorting link when making two-pole measurements, this ground tester also offers labeled auxiliary controls used to select the test frequency (94, 105, 111, and 128 Hz), output voltage (50 or 25 V where local standards apply), and to switch the backlight on or off.

Features

DET4TC2:

  • Stakeless testing capability - Allows the operator to use the instrument like a clamp-on tester in applications where the method is viable
  • Attached Rod Technique capability - Allows fall of potential testing without the need to disconnect the ground rod
  • Multiple user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • 200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil
  • User selectable test voltage ensures that the units can be used in agricultural environments
  • Microprocessor control for improved error detection
  • Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
  • Rugged, weatherproof case to IP54
  • Backlit LCD allows for testing in dark environments
  • Noise rejection to 40 V pk to pk allows accurate testing in noisy environments
  • Accuracy of 2% of reading enhances reliability of measurements
  • Voltmeter function allows you to measure the ground voltage and enhances operator safety
  • CAT IV 100V provides increased operator safety

ETK50C:

  • For use with ground tester models DET2/2, DET2/3, DET3 and DET4
  • Suitable for use with MFT multifunction testers
  • Reels can be daisy chained together, providing longer lengths in manageable chunks - Manageable chunks make reels lighter and easier to carry, helping to quickly resolve any connectivity issues
  • Stakeless testing can be performed with included MCC1010 current clamp or MVC1010 voltage clamp
  • Reels offer a sturdy handle as well as clips for holding earth spikes and test leads ends
  • Smooth unwind and wind action allows for easy operation
  • Reels sit firmly on ground or any flat surface to ensure reliable testing
  • Durable spikes can be hammered into ground
  • Water-resistant carrying bag features toughened bottom for outdoor use

Applications

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger 1012-521 Specifications

DET4TC2
Resistance Range 0.01 Ω to 20 kΩ
Resistance Accuracy 2p Measurements: 2% ±3 digits
3p Measurements: 2% ±3 digits
4p Measurements: 2% ±3 digits
ART Measurements: 5% ±3 digits
Stakeless Measurements: 7% ±3 digits
Maximum Probe Resistance Rp limit: 200 kΩ (50 V output voltage)
Rc limit: 200 kΩ (50 V output voltage)
Limits reduced to 100 kΩ for 25 V output voltage
Limits reduced to 5 kΩ for 0.01 Ω resolution
Earth Voltage Range: 0 to 100 V AC
Accuracy: 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check: Automatic
Rejection: 40 V pk to pk
Test Frequency: 94, 105, 111 and 128 Hz
Voltage: 25 or 50 V, user selectable (factory setting 50 V)
Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V
Display 3.5" (8.89 cm) digit high contrast LCD, backlit
Battery Type: 8 x 1.5 V AA cells
Life: 3 hours, 700 consecutive tests
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Humidity 95% RH non-condensing at 104°F (40°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)
Click here for complete specifications on the Megger 1012-521

What's included with the Megger 1012-521

  • Ground Resistance Tester
  • 4 x Test Leads (49', 33', 33', 10')
  • 4 x Spikes
  • 2 x Reels with 165' (50 m) Test Cable (Red/Yellow)
  • 2 x Reels with 100' (30 m) Test Cable (Green/Black)
  • MCC1010 Current Clamp
  • MCC1010 Test Lead
  • MVC1010 Voltage Clamp
  • MVC1010 Test Lead
  • 4 x Earth Test Spikes
  • 4 x Interconnection Leads (Red/Yellow/Black/Green)
  • 2 x 4.5' (1.4 m) Leads with Connectors and Clips
  • 330' (100 m) Tape Measure
  • 2 x Carrying Case
  • 8 x 1.5 V AA Cells Batteries
  • Certificate of Calibration
  • 2-Year Warranty

Ask a question about Megger 1012-521 DET4TC2 Four-Terminal Digital Ground Resistance Tester with ETK50C Earth Test Kit

Customer Reviews for the Megger 1012-521

Megger 1012-521 Offers

Designed to negate the need for a shorting link when making two-pole measurements, this ground tester also offers labeled auxiliary controls used to select the test frequency (94, 105, 111, and 128 Hz), output voltage (50 or 25 V where local standards apply), and to switch the backlight on or off.

Features

DET4TC2:

  • Stakeless testing capability - Allows the operator to use the instrument like a clamp-on tester in applications where the method is viable
  • Attached Rod Technique capability - Allows fall of potential testing without the need to disconnect the ground rod
  • Multiple user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • 200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil
  • User selectable test voltage ensures that the units can be used in agricultural environments
  • Microprocessor control for improved error detection
  • Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
  • Rugged, weatherproof case to IP54
  • Backlit LCD allows for testing in dark environments
  • Noise rejection to 40 V pk to pk allows accurate testing in noisy environments
  • Accuracy of 2% of reading enhances reliability of measurements
  • Voltmeter function allows you to measure the ground voltage and enhances operator safety
  • CAT IV 100V provides increased operator safety

ETK50C:

  • For use with ground tester models DET2/2, DET2/3, DET3 and DET4
  • Suitable for use with MFT multifunction testers
  • Reels can be daisy chained together, providing longer lengths in manageable chunks - Manageable chunks make reels lighter and easier to carry, helping to quickly resolve any connectivity issues
  • Stakeless testing can be performed with included MCC1010 current clamp or MVC1010 voltage clamp
  • Reels offer a sturdy handle as well as clips for holding earth spikes and test leads ends
  • Smooth unwind and wind action allows for easy operation
  • Reels sit firmly on ground or any flat surface to ensure reliable testing
  • Durable spikes can be hammered into ground
  • Water-resistant carrying bag features toughened bottom for outdoor use

Applications

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RFI system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger 1012-521 Specifications

DET4TC2
Resistance Range 0.01 Ω to 20 kΩ
Resistance Accuracy 2p Measurements: 2% ±3 digits
3p Measurements: 2% ±3 digits
4p Measurements: 2% ±3 digits
ART Measurements: 5% ±3 digits
Stakeless Measurements: 7% ±3 digits
Maximum Probe Resistance Rp limit: 200 kΩ (50 V output voltage)
Rc limit: 200 kΩ (50 V output voltage)
Limits reduced to 100 kΩ for 25 V output voltage
Limits reduced to 5 kΩ for 0.01 Ω resolution
Earth Voltage Range: 0 to 100 V AC
Accuracy: 2% ±2 V
C Spike Check Automatic
P Spike Check Automatic
Noise Check: Automatic
Rejection: 40 V pk to pk
Test Frequency: 94, 105, 111 and 128 Hz
Voltage: 25 or 50 V, user selectable (factory setting 50 V)
Current: 450 micro-amps at 25 or 50 V (selectable), 4.5 mA at 25 V
Display 3.5" (8.89 cm) digit high contrast LCD, backlit
Battery Type: 8 x 1.5 V AA cells
Life: 3 hours, 700 consecutive tests
Temperature Range Operating: 5 to 131°F (-15 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Humidity 95% RH non-condensing at 104°F (40°C)
Safety EN61010-1 CAT IV 100 V
Ingress Protection IP54
Dimensions 8 x 5.7 x 3.2" (203 x 148 x 78 mm)
Weight 2.20 lbs (1 kg)
Click here for complete specifications on the Megger 1012-521

What's included with the Megger 1012-521

  • Ground Resistance Tester
  • 4 x Test Leads (49', 33', 33', 10')
  • 4 x Spikes
  • 2 x Reels with 165' (50 m) Test Cable (Red/Yellow)
  • 2 x Reels with 100' (30 m) Test Cable (Green/Black)
  • MCC1010 Current Clamp
  • MCC1010 Test Lead
  • MVC1010 Voltage Clamp
  • MVC1010 Test Lead
  • 4 x Earth Test Spikes
  • 4 x Interconnection Leads (Red/Yellow/Black/Green)
  • 2 x 4.5' (1.4 m) Leads with Connectors and Clips
  • 330' (100 m) Tape Measure
  • 2 x Carrying Case
  • 8 x 1.5 V AA Cells Batteries
  • Certificate of Calibration
  • 2-Year Warranty

Ask a question about Megger 1012-521 DET4TC2 Four-Terminal Digital Ground Resistance Tester with ETK50C Earth Test Kit

Customer Reviews for the Megger 1012-521

More Megger Products

How to Effectively Protect and Maintain Wind Turbines