Reading 0 to 100 psig from a hydronic or compressed air line, this gauge pressure transmitter sends a 4-20 mA signal over two wires to a controller or panel meter. A Packard connector makes the electrical termination a plug-in step, and the stainless steel process connection threads directly into standard fittings.

Reading 0 to 100 psig from a hydronic or compressed air line, this gauge pressure transmitter sends a 4-20 mA signal over two wires to a controller or panel meter. A Packard connector makes the electrical termination a plug-in step, and the stainless steel process connection threads directly into standard fittings.

Sale Price $223.75 USD
Regular Price $546.00 USD
Availability 2 to 3 Weeks
Quantity

ACI GP(0-100G)-20-P Offers

The GP Series is designed to provide excellent accuracy and reliability in commercial, industrial, and process control applications where performance is critical. The bulk micro-machined transducer features a stainless steel diaphragm with welded construction that contains no O-rings, which makes them compatible with any gas or liquid compatible with 304L stainless steel. Some of the compatible gases and liquids include refrigerants, glycol, motor oil, diesel, hydraulic fluid, brake fluid, water, waste water, Hydrogen, Nitrogen and air. The GP Series transducers can also be ordered in an optional NEMA 4 rated, weatherproof metal enclosure or a NIST Calibration Certificate.

Features

  • Packard connector makes the electrical termination a plug-in step
  • Two-wire 4-20 mA loop over a single pair
  • Stainless steel process connection threads into standard fittings
  • Harnesses available in 6, 10 and 20 ft lengths (Sold Separately)

Applications

  • Refrigeration
  • Fuel cells
  • Pumps
  • Hydraulics
  • Compressors
  • Robotics
  • Pneumatics
  • Agriculture
  • Spraying systems
  • Process control
  • Flow
  • Hydrogen storage

ACI GP(0-100G)-20-P Specifications

Pressure Range 0 to 100 psig
Accuracy @ 22°C (71.6°F) 15 to 60 psig: < ± 1.0% FS | 75 to 300 psig: < ± 0.5% FS | 500 psis 3: < ± 0.5% FS
Stability (250 Hours @ 225°F (125°C)) ± 0.03% FS @ 0 PSIG; ± 0.12% FS @ 1000 PSIG
Output Signal 4 to 20 mA (2-Wire, Loop Powered)
Maximum Load Resistance 800 Ohms @ 24 V DC | Formula: (Supply VDC - 8 V DC) / 0.020A
Supply Current 25 mA minimum
Supply Voltage 250 Ohm Load: +13 to 30 V DC | 500 Ohm Load: 18 to 30 V DC
Reverse Polarity Protection ± 16 V over 5 minutes
Recommended Torque Specification 150 lbs-in (16.95 Nm)
Burst Pressure 15 to 300 psig: 3x FS | 500 psis: 3x FS
Media Types Any gas or liquid compatible with 304L Stainless Steel
Proof Pressure 15 to 300 psig: 3x FS | 500 psis: 3x FS
Thermal Error (-40° to 105°C) 15 to 60 psig: < ± 1.0 FS | 75 to 300 psig: < ± 0.5% FS | 500 psis 3: < ± 0.5% FS
Thermal Shock 300 Cycles (105°C to -40°C, 0.5 hr soaks @ Temp. (2s Transfer))
Vibration (100 to 2000Hz, 20g Sinusoidal, 3 Axes) 144 Hours
Operating Humidity Range 0 to 95% RH, non-condensing
Operating Temperature Range -40 to 257°F (-40 to 125°C)
Storage Temperature Range -40 to 176°F (-40 to 80°C)
Process Fitting Material | Thread Size 304L Stainless Steel | 1/4"-18 NPT
Transducer Housing Material Stainless Steel
Product Dimensions (L x W x H) 2.70 x 0.95 x 0.85" (68.6 x 24.1 x 21.6 mm)
Product Weight 0.15 lbs (70 g)
Approvals EMC Compliance: 10 V/m (EN61000-4-3), CE, RoHS2, WEEE, ISO 9001
Click here for complete specifications on the ACI GP(0-100G)-20-P

What's included with the ACI GP(0-100G)-20-P

  • Gauge Pressure Transmitter
  • Two-Year Warranty

Click on a category to view a selection of compatible accessories with the ACI GP Series Gauge Pressure Transmitter, 0 to 100 psig, 4-20 mA output.

ACI A Series Gauge Pressure Transmitter Harness, 6' leads A/GP 6'HARNESS
Terminating a Packard-connector pressure transmitter, this harness runs 6' of shielded cable from the sensor back to the panel. One end plugs onto the transmitter and the other lands as flying leads straight on a terminal block, so the run needs no field-assembled connector and no adapter. Ordering it alongside the transmitter keeps the installation to one part number per end.




ACI A Series Gauge Pressure Transmitter Harness, 10' leads A/GP 10'HARNESS
Terminating a Packard-connector pressure transmitter, this harness runs 10' of shielded cable from the sensor back to the panel. One end plugs onto the transmitter and the other lands as flying leads straight on a terminal block, so the run needs no field-assembled connector and no adapter. Ordering it alongside the transmitter keeps the installation to one part number per end.




ACI A Series Gauge Pressure Transmitter Harness, 20' leads A/GP 20'HARNESS
Terminating a Packard-connector pressure transmitter, this harness runs 20' of shielded cable from the sensor back to the panel. One end plugs onto the transmitter and the other lands as flying leads straight on a terminal block, so the run needs no field-assembled connector and no adapter. Ordering it alongside the transmitter keeps the installation to one part number per end.




Ask a question about ACI GP Series Gauge Pressure Transmitter, 0 to 100 psig, 4-20 mA output

Customer Reviews for the ACI GP(0-100G)-20-P

ACI GP(0-100G)-20-P Offers

The GP Series is designed to provide excellent accuracy and reliability in commercial, industrial, and process control applications where performance is critical. The bulk micro-machined transducer features a stainless steel diaphragm with welded construction that contains no O-rings, which makes them compatible with any gas or liquid compatible with 304L stainless steel. Some of the compatible gases and liquids include refrigerants, glycol, motor oil, diesel, hydraulic fluid, brake fluid, water, waste water, Hydrogen, Nitrogen and air. The GP Series transducers can also be ordered in an optional NEMA 4 rated, weatherproof metal enclosure or a NIST Calibration Certificate.

Features

  • Packard connector makes the electrical termination a plug-in step
  • Two-wire 4-20 mA loop over a single pair
  • Stainless steel process connection threads into standard fittings
  • Harnesses available in 6, 10 and 20 ft lengths (Sold Separately)

Applications

  • Refrigeration
  • Fuel cells
  • Pumps
  • Hydraulics
  • Compressors
  • Robotics
  • Pneumatics
  • Agriculture
  • Spraying systems
  • Process control
  • Flow
  • Hydrogen storage

ACI GP(0-100G)-20-P Specifications

Pressure Range 0 to 100 psig
Accuracy @ 22°C (71.6°F) 15 to 60 psig: < ± 1.0% FS | 75 to 300 psig: < ± 0.5% FS | 500 psis 3: < ± 0.5% FS
Stability (250 Hours @ 225°F (125°C)) ± 0.03% FS @ 0 PSIG; ± 0.12% FS @ 1000 PSIG
Output Signal 4 to 20 mA (2-Wire, Loop Powered)
Maximum Load Resistance 800 Ohms @ 24 V DC | Formula: (Supply VDC - 8 V DC) / 0.020A
Supply Current 25 mA minimum
Supply Voltage 250 Ohm Load: +13 to 30 V DC | 500 Ohm Load: 18 to 30 V DC
Reverse Polarity Protection ± 16 V over 5 minutes
Recommended Torque Specification 150 lbs-in (16.95 Nm)
Burst Pressure 15 to 300 psig: 3x FS | 500 psis: 3x FS
Media Types Any gas or liquid compatible with 304L Stainless Steel
Proof Pressure 15 to 300 psig: 3x FS | 500 psis: 3x FS
Thermal Error (-40° to 105°C) 15 to 60 psig: < ± 1.0 FS | 75 to 300 psig: < ± 0.5% FS | 500 psis 3: < ± 0.5% FS
Thermal Shock 300 Cycles (105°C to -40°C, 0.5 hr soaks @ Temp. (2s Transfer))
Vibration (100 to 2000Hz, 20g Sinusoidal, 3 Axes) 144 Hours
Operating Humidity Range 0 to 95% RH, non-condensing
Operating Temperature Range -40 to 257°F (-40 to 125°C)
Storage Temperature Range -40 to 176°F (-40 to 80°C)
Process Fitting Material | Thread Size 304L Stainless Steel | 1/4"-18 NPT
Transducer Housing Material Stainless Steel
Product Dimensions (L x W x H) 2.70 x 0.95 x 0.85" (68.6 x 24.1 x 21.6 mm)
Product Weight 0.15 lbs (70 g)
Approvals EMC Compliance: 10 V/m (EN61000-4-3), CE, RoHS2, WEEE, ISO 9001
Click here for complete specifications on the ACI GP(0-100G)-20-P

What's included with the ACI GP(0-100G)-20-P

  • Gauge Pressure Transmitter
  • Two-Year Warranty

Click on a category to view a selection of compatible accessories with the ACI GP Series Gauge Pressure Transmitter, 0 to 100 psig, 4-20 mA output.

ACI A Series Gauge Pressure Transmitter Harness, 6' leads A/GP 6'HARNESS
Terminating a Packard-connector pressure transmitter, this harness runs 6' of shielded cable from the sensor back to the panel. One end plugs onto the transmitter and the other lands as flying leads straight on a terminal block, so the run needs no field-assembled connector and no adapter. Ordering it alongside the transmitter keeps the installation to one part number per end.




ACI A Series Gauge Pressure Transmitter Harness, 10' leads A/GP 10'HARNESS
Terminating a Packard-connector pressure transmitter, this harness runs 10' of shielded cable from the sensor back to the panel. One end plugs onto the transmitter and the other lands as flying leads straight on a terminal block, so the run needs no field-assembled connector and no adapter. Ordering it alongside the transmitter keeps the installation to one part number per end.




ACI A Series Gauge Pressure Transmitter Harness, 20' leads A/GP 20'HARNESS
Terminating a Packard-connector pressure transmitter, this harness runs 20' of shielded cable from the sensor back to the panel. One end plugs onto the transmitter and the other lands as flying leads straight on a terminal block, so the run needs no field-assembled connector and no adapter. Ordering it alongside the transmitter keeps the installation to one part number per end.




Ask a question about ACI GP Series Gauge Pressure Transmitter, 0 to 100 psig, 4-20 mA output

Customer Reviews for the ACI GP(0-100G)-20-P

More ACI Products