Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Model: AcuRev-1312-333-X1 | Order No: AcuRev 1312-333-X1

Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Model: AcuRev-1312-333-X1 | Order No: AcuRev 1312-333-X1

Three-phase multi-circuit power and energy meter tracks active, reactive and apparent energy and power, as well as power and current demand, offers revenue grade accuracy, features built-in pulse/alarm output and optional relay output, accepts 333 mV current transformer (CT) input, measures neutral current with the fourth CT and provides residual current measurement.

Three-phase multi-circuit power and energy meter tracks active, reactive and apparent energy and power, as well as power and current demand, offers revenue grade accuracy, features built-in pulse/alarm output and optional relay output, accepts 333 mV current transformer (CT) input, measures neutral current with the fourth CT and provides residual current measurement.

Sale Price $276.92 USD
Regular Price $301.00 USD
Availability 4 to 5 Weeks
Quantity

Accuenergy AcuRev-1312-333-X1 Specifications

Parameter AccuracyResolutionRange
Active Energy 0.50%1Wh0 to 999999999kWh
Reactive Energy 0.50%1varh0 to 999999999kvarh
Apparent Energy 0.50%1VAh0 to 999999999kVAh
Voltage 0.50%0.110V to 1000KV
Current 0.50%0.001A10mA to 500000A
Active Power 0.50%1W-99 to 99MW
Reactive Power 0.50%1var-99 to 99Mvar
Apparent Power 0.50%1VA-99 to 99MVA
Power Factor 0.50%0.001-1.000 to 1.000
Frequency 0.20%0.01Hz50/60Hz
Power Demand 0.50%1W/var/VA99MW/Mvar/MVA
Current Demand 0.50%0.001A10mA to 5000A
Click here for complete specifications on the Accuenergy AcuRev-1312-333-X1

What's included with the Accuenergy AcuRev-1312-333-X1

  • Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Click on a category to view a selection of compatible accessories with the Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output.

Accuenergy AcuCT-125-400:333 Split Core Current Transformer, 1.25 x 1.25", 400 A:333 mV AcuCT-125-400:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 1.25 x 1.25", and current input of 400 A.




Accuenergy AcuCT-125-600:333 Split Core Current Transformer, 1.25 x 1.25", 600 A:333 mV AcuCT-125-600:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 1.25 x 1.25", and current input of 600 A.




Accuenergy AcuCT-3050-5000:333 Split Core Current Transformer, 3 x 5", 5000 A:333 mV AcuCT-3050-5000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 5000 A.




Accuenergy AcuCT-3050-3000:333 Split Core Current Transformer, 3 x 5", 3000 A:333 mV AcuCT-3050-3000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 3000 A.




Accuenergy AcuCT-3050-2000:333 Split Core Current Transformer, 3 x 5", 2000 A:333 mV AcuCT-3050-2000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 2000 A.




Accuenergy AcuCT-3050-1500:333 Split Core Current Transformer, 3 x 5", 1500 A:333 mV AcuCT-3050-1500:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 1500 A.




Accuenergy AcuCT-200-1500:333 Split Core Current Transformer, 2 x 2", 1500 A:333 mV AcuCT-200-1500:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 1500 A.




Accuenergy AcuCT-200-1000:333 Split Core Current Transformer, 2 x 2", 1000 A:333 mV AcuCT-200-1000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 1000 A.




Accuenergy AcuCT-200-800:333 Split Core Current Transformer, 2 x 2", 800 A:333 mV AcuCT-200-800:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 800 A.




Accuenergy AcuCT-200-1200:333 Split Core Current Transformer, 2 x 2", 1200 A:333 mV AcuCT-200-1200:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 1200 A.




Accuenergy AcuCT-200-600:333 Split Core Current Transformer, 2 x 2", 600 A:333 mV AcuCT-200-600:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 600 A.




Accuenergy AcuCT-075-200:333 Split Core Current Transformer, 0.75 x 0.75", 200 A:333 mV AcuCT-075-200:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 0.75 x 0.75", and current input of 200 A.




Accuenergy AcuCT-075-100:333 Split Core Current Transformer, 0.75 x 0.75", 100 A:333 mV AcuCT-075-100:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 0.75 x 0.75", and current input of 100 A.




Ask a question about Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Customer Reviews for the Accuenergy AcuRev-1312-333-X1

Accuenergy AcuRev-1312-333-X1 Specifications

Parameter AccuracyResolutionRange
Active Energy 0.50%1Wh0 to 999999999kWh
Reactive Energy 0.50%1varh0 to 999999999kvarh
Apparent Energy 0.50%1VAh0 to 999999999kVAh
Voltage 0.50%0.110V to 1000KV
Current 0.50%0.001A10mA to 500000A
Active Power 0.50%1W-99 to 99MW
Reactive Power 0.50%1var-99 to 99Mvar
Apparent Power 0.50%1VA-99 to 99MVA
Power Factor 0.50%0.001-1.000 to 1.000
Frequency 0.20%0.01Hz50/60Hz
Power Demand 0.50%1W/var/VA99MW/Mvar/MVA
Current Demand 0.50%0.001A10mA to 5000A
Click here for complete specifications on the Accuenergy AcuRev-1312-333-X1

What's included with the Accuenergy AcuRev-1312-333-X1

  • Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Click on a category to view a selection of compatible accessories with the Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output.

Accuenergy AcuCT-125-400:333 Split Core Current Transformer, 1.25 x 1.25", 400 A:333 mV AcuCT-125-400:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 1.25 x 1.25", and current input of 400 A.




Accuenergy AcuCT-125-600:333 Split Core Current Transformer, 1.25 x 1.25", 600 A:333 mV AcuCT-125-600:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 1.25 x 1.25", and current input of 600 A.




Accuenergy AcuCT-3050-5000:333 Split Core Current Transformer, 3 x 5", 5000 A:333 mV AcuCT-3050-5000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 5000 A.




Accuenergy AcuCT-3050-3000:333 Split Core Current Transformer, 3 x 5", 3000 A:333 mV AcuCT-3050-3000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 3000 A.




Accuenergy AcuCT-3050-2000:333 Split Core Current Transformer, 3 x 5", 2000 A:333 mV AcuCT-3050-2000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 2000 A.




Accuenergy AcuCT-3050-1500:333 Split Core Current Transformer, 3 x 5", 1500 A:333 mV AcuCT-3050-1500:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 3 x 5", and current input of 1500 A.




Accuenergy AcuCT-200-1500:333 Split Core Current Transformer, 2 x 2", 1500 A:333 mV AcuCT-200-1500:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 1500 A.




Accuenergy AcuCT-200-1000:333 Split Core Current Transformer, 2 x 2", 1000 A:333 mV AcuCT-200-1000:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 1000 A.




Accuenergy AcuCT-200-800:333 Split Core Current Transformer, 2 x 2", 800 A:333 mV AcuCT-200-800:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 800 A.




Accuenergy AcuCT-200-1200:333 Split Core Current Transformer, 2 x 2", 1200 A:333 mV AcuCT-200-1200:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 1200 A.




Accuenergy AcuCT-200-600:333 Split Core Current Transformer, 2 x 2", 600 A:333 mV AcuCT-200-600:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 2 x 2", and current input of 600 A.




Accuenergy AcuCT-075-200:333 Split Core Current Transformer, 0.75 x 0.75", 200 A:333 mV AcuCT-075-200:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 0.75 x 0.75", and current input of 200 A.




Accuenergy AcuCT-075-100:333 Split Core Current Transformer, 0.75 x 0.75", 100 A:333 mV AcuCT-075-100:333
Conventional split core current transformer features a 333 mV low voltage output for safe opening, a window size of 0.75 x 0.75", and current input of 100 A.




Ask a question about Accuenergy AcuRev 1312-333-X1 DIN Rail Power/Energy Meter, 333 mV CT input, relay output

Customer Reviews for the Accuenergy AcuRev-1312-333-X1

More Accuenergy Products