General Specifications
Display: Fully annunciated 4-digit liquid crystal display (LCD) with maximum reading of 4,000 count. Dual display in Temperature mode. 12 segments analog bar graph. Automatic polarity indication.
Functions: DCV, ACV, DCA, ACA, OHM, Capacitance and Temperature.
Measuring rate:3.3 times per second for V, A, Ohm and Temperature tests. 0.5 - 7.6 seconds per time for Capacitance test. Low battery indicator: The "'q " appears when the battery voltage drops below 7V (approx.).
Operating temperature: 0 * C to 50 * C (32 * F to 122 * F), 0 - 80% R.H.
Storage temperature: -20'C to 60 * C (-4'F to 140 - F), 0 - 80% R. H. with BATTERYREMOVED.
Temperature coefficient: 0.12 % / *C(fr0m O'C to 18 *C or 28 *C to 50 'C),0.067 % / 'F(from 32 * F to 64.4 * F or 82.4 * F to 122 * F), or otherwise specified.
Power supply: Single standard NEDA1604, JIS006P,IEC6F22 carbonzinc or alkaline type 9V battery.
|