Yellow Jacket 69336 HVAC/R Refrigerant Leak Detector

Model: 69336 | UPC: 686800693361

Yellow Jacket 69336 HVAC/R Refrigerant Leak Detector

Model: 69336 | UPC: 686800693361

This leak detector utilizes an ultra-sensitive electrolyte sensor, UV light technology, and a Smart Alarm LED indicator to accurately detect HFC, HCFC, and CFC refrigerants, including SNAP-approved hydrocarbon blends. Given the high cost of refrigerants, service technicians working with A/C, refrigeration, and automotive systems require a reliable leak detector that can quickly and accurately pinpoint leaks to minimize refrigerant loss.

This leak detector utilizes an ultra-sensitive electrolyte sensor, UV light technology, and a Smart Alarm LED indicator to accurately detect HFC, HCFC, and CFC refrigerants, including SNAP-approved hydrocarbon blends. Given the high cost of refrigerants, service technicians working with A/C, refrigeration, and automotive systems require a reliable leak detector that can quickly and accurately pinpoint leaks to minimize refrigerant loss.

Your Price $636.89 USD
Availability 1 in Stock
Quantity

YELLOW JACKET® 69336 Offers

Detects even the most difficult to detect R-134a, R-404A, R-407C, R-410A, and 1234yf refrigerants. The Yellow Jacket AccuProbe UV has an ultra-sensitive electrolyte sensor, UV light technology, and a Smart Alarm LED indicator to detect HFC, HCFC and CFC refrigerants including the SNAP-approved hydrocarbon blends efficiently and accurately. Due to the high cost of refrigerant, a service technician working with A/C, refrigeration, and automotive systems needs a reliable refrigerant leak detector that can pinpoint leaks quickly and accurately so refrigerant loss is at a minimum. The Yellow Jacket 69336 AccuProbe is perfect for the maintenance of air conditioning and refrigeration systems in residential and commercial buildings as well as automotive A/C systems.

The AccuProbe UV 69336 leak detector has a sensitivity that ranges from 0.03 oz./year for R-22 to 0.06 oz./year for R-134a and R-1234yf type refrigerants. This Freon leak detector has three selectable sensitivity levels to pinpoint leaks and a mechanical pump that quickly clears the refrigerant from the sensor automatically resetting it to the ambient air. This hand held refrigerant leak detector responds to changes in concentration of refrigerant so if held in one area the sensor will adjust to the refrigerant level in that area and cease to detect a leak.

The audible alert, which can be muted, and the flashing visual alarm indicator at the probe end increases in frequency and duration as the concentration increases. This leak detector is also equipped with an advanced digital Smart Alarm LED display. This feature takes the guesswork out of whether or not to repair a small leak. Unlike the more traditional LED bar graphs that copy or mimic the audio alarm signal, the Smart Alarm digital leak size indicator measures, registers, and displays the leak size independently from both the audio alarm and sensitivity level on a scale of one to nine.

In addition, the leak detector's has a 3 LED UV light system that works with 395 to 415 nm wavelength leak tracing dyes to locate the source of leaks especially the small intermittent leaks that are hard to find. The tracing dyes stay in the system forever so in future service calls it will be easy to scan the system for leaks using the AccuProbe UV light. The 17 flexible probe with a flashing visual alarm indicator at the probe end is easy to use in close areas and easily extended into hard to reach areas.

Features

  • Detects HFC, HCFC, CFC including SNAP blends
  • Sensitivity 0.03 oz./year for R-22 to 0.06 oz./year for R-134A type refrigerants
  • Three selectable sensitivity settings
  • Visual and audible alerts
  • 3 LED UV light system
  • SAE J2791 Certified
  • 1 to 3 - leak is less than 0.1 oz./yr.
  • 4 to 6 - leak is 0.1 to 0.5 oz./yr.
  • 7 to 9 - leak is more than 0.5 oz./yr.
  • Improved, robust, ergonomic design is easy to use in close areas and extendable into hard-to-reach areas
  • Long life, stable sensor
  • Instantaneous response time
  • Clears quickly from large amounts of refrigerant
  • Automatic calibration and reset to environment
  • Low battery indicator
  • Microcontroller technology
  • SAE J2791 Certified
  • CE Marked
  • Made in the USA

YELLOW JACKET® 69336 Specifications

Sensitivity 0.06 oz./yr. (1.7 g/yr.) HFCs R-134a, 0.03 oz./yr. (0.9 g/yr.) HCFCs R-22
Operating Temperature Range 24 to 125°F (-4 to 52°C)
Humidity 0 to 95 percent RH non-condensing
Power 4 AA alkaline batteries, 8 hours continuous life
Battery Life 4.5 hours continuous
Body Length 10.5" (270 mm)
Probe Length 17" (430 mm)
Weight 17 oz (480 g)
Calibration Automatic
Sensor Life >300 hours
Response Time Instantaneous

What's included with the YELLOW JACKET® 69336

  • AccuProbe UV
  • Leak standard solution
  • Four AA batteries
  • Carrying Pouch
  • Instruction Manual
  • 18 month limited warranty

Click on a category to view a selection of compatible accessories with the Yellow Jacket 69336 HVAC/R Refrigerant Leak Detector.

Yellow Jacket 61152 FINFIX 2 COMB 9 & 15 /IN 61152
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Yellow Jacket 61153 FINFIX 3 COMB 11 & 13 /IN 61153
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Yellow Jacket 61155 FINFIX 5 COMB 16 & 17 /IN 61155
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Yellow Jacket 61156 FINFIX 6 COMB 18 & 20 /IN 61156
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Ask a question about Yellow Jacket 69336 HVAC/R Refrigerant Leak Detector

Customer Reviews for the YELLOW JACKET® 69336

YELLOW JACKET® 69336 Offers

Detects even the most difficult to detect R-134a, R-404A, R-407C, R-410A, and 1234yf refrigerants. The Yellow Jacket AccuProbe UV has an ultra-sensitive electrolyte sensor, UV light technology, and a Smart Alarm LED indicator to detect HFC, HCFC and CFC refrigerants including the SNAP-approved hydrocarbon blends efficiently and accurately. Due to the high cost of refrigerant, a service technician working with A/C, refrigeration, and automotive systems needs a reliable refrigerant leak detector that can pinpoint leaks quickly and accurately so refrigerant loss is at a minimum. The Yellow Jacket 69336 AccuProbe is perfect for the maintenance of air conditioning and refrigeration systems in residential and commercial buildings as well as automotive A/C systems.

The AccuProbe UV 69336 leak detector has a sensitivity that ranges from 0.03 oz./year for R-22 to 0.06 oz./year for R-134a and R-1234yf type refrigerants. This Freon leak detector has three selectable sensitivity levels to pinpoint leaks and a mechanical pump that quickly clears the refrigerant from the sensor automatically resetting it to the ambient air. This hand held refrigerant leak detector responds to changes in concentration of refrigerant so if held in one area the sensor will adjust to the refrigerant level in that area and cease to detect a leak.

The audible alert, which can be muted, and the flashing visual alarm indicator at the probe end increases in frequency and duration as the concentration increases. This leak detector is also equipped with an advanced digital Smart Alarm LED display. This feature takes the guesswork out of whether or not to repair a small leak. Unlike the more traditional LED bar graphs that copy or mimic the audio alarm signal, the Smart Alarm digital leak size indicator measures, registers, and displays the leak size independently from both the audio alarm and sensitivity level on a scale of one to nine.

In addition, the leak detector's has a 3 LED UV light system that works with 395 to 415 nm wavelength leak tracing dyes to locate the source of leaks especially the small intermittent leaks that are hard to find. The tracing dyes stay in the system forever so in future service calls it will be easy to scan the system for leaks using the AccuProbe UV light. The 17 flexible probe with a flashing visual alarm indicator at the probe end is easy to use in close areas and easily extended into hard to reach areas.

Features

  • Detects HFC, HCFC, CFC including SNAP blends
  • Sensitivity 0.03 oz./year for R-22 to 0.06 oz./year for R-134A type refrigerants
  • Three selectable sensitivity settings
  • Visual and audible alerts
  • 3 LED UV light system
  • SAE J2791 Certified
  • 1 to 3 - leak is less than 0.1 oz./yr.
  • 4 to 6 - leak is 0.1 to 0.5 oz./yr.
  • 7 to 9 - leak is more than 0.5 oz./yr.
  • Improved, robust, ergonomic design is easy to use in close areas and extendable into hard-to-reach areas
  • Long life, stable sensor
  • Instantaneous response time
  • Clears quickly from large amounts of refrigerant
  • Automatic calibration and reset to environment
  • Low battery indicator
  • Microcontroller technology
  • SAE J2791 Certified
  • CE Marked
  • Made in the USA

YELLOW JACKET® 69336 Specifications

Sensitivity 0.06 oz./yr. (1.7 g/yr.) HFCs R-134a, 0.03 oz./yr. (0.9 g/yr.) HCFCs R-22
Operating Temperature Range 24 to 125°F (-4 to 52°C)
Humidity 0 to 95 percent RH non-condensing
Power 4 AA alkaline batteries, 8 hours continuous life
Battery Life 4.5 hours continuous
Body Length 10.5" (270 mm)
Probe Length 17" (430 mm)
Weight 17 oz (480 g)
Calibration Automatic
Sensor Life >300 hours
Response Time Instantaneous

What's included with the YELLOW JACKET® 69336

  • AccuProbe UV
  • Leak standard solution
  • Four AA batteries
  • Carrying Pouch
  • Instruction Manual
  • 18 month limited warranty

Click on a category to view a selection of compatible accessories with the Yellow Jacket 69336 HVAC/R Refrigerant Leak Detector.

Yellow Jacket 61152 FINFIX 2 COMB 9 & 15 /IN 61152
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Yellow Jacket 61153 FINFIX 3 COMB 11 & 13 /IN 61153
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Yellow Jacket 61155 FINFIX 5 COMB 16 & 17 /IN 61155
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Yellow Jacket 61156 FINFIX 6 COMB 18 & 20 /IN 61156
Color-coded nylon fin combs designed to easily straighten and clean fins on standard and high efficiency condensers and evaporators.




Ask a question about Yellow Jacket 69336 HVAC/R Refrigerant Leak Detector

Customer Reviews for the YELLOW JACKET® 69336

More YELLOW JACKET® Products

Calibration Lab