Veris PWLX05S Wet Media Differential Pressure Transducer, 0 to 250 psig

Model: PWLX05S

Veris PWLX05S Wet Media Differential Pressure Transducer, 0 to 250 psig

Model: PWLX05S

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.

Sale Price $418.86 USD
Regular Price $1621.11 USD
Availability 5 to 6 Weeks
Quantity

Veris PWLX05S Offers

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.

Features

  • Jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Jumper-controlled electronic surge dampening for high stability
  • Push-button zero calibration ensures there are no trim pots to adjust
  • Lowest total installed cost
  • Jumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed; simply change the jumper position from normal to swap and problem solved!
  • Dual sensor design eliminates the requirement for a bypass valve assembly in most applications
  • Switch-selectable pressure ranges means fewer models to order and stock
  • Push-button and remote zero adjustment help maintain accuracy and prevent callbacks with automatic zero calibration

Applications

  • Monitoring and Controlling Pump Differential Pressure
  • Chiller/Boiler Differential Pressure Drop
  • CW/HW System Differential Pressure

Veris PWLX05S Specifications

Input Power 12 to 30 V DC/24 VAC nominal
Maximum Current Draw DC: 125 mA; AC: 280 mA
Output 3-wire transmitter; user selectable 4 to 20 mA, (clipped and capped)/0 to 5 V/0 to 10 V
Surge Damping Electronic; 5-second averaging
Accuracy At 77°C (25°C): ±1% FS (range A, B, C), ±2% FS (range D)
Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V)
Pressure Range (Selectable) 0 to 10/20/50/100 psid (0 to 0.34/0.69/1.72/3.45 bar)
Product Operating Environment -140 to 130°F (-10 to 55°C); 0 to 90% RH, non-condensing
Long Term Stability ±0.25% per year
Zero Adjust Push-button auto-zero and digital input (2-pos terminal block)
Status Indication Dual-color LED: green = normal, green blinking = low > high, red = over-range, red blinking = over-pressure
Housing Material White powder-coat aluminum
Media Compatibility Media compatible with 17 to 4 PH stainless steel
Proof Pressure Max 2 x FS range
Burst Pressure Max 5 x FS range
Temperature Compensated Range 32 to 122°F (0 to 50°C); TC Zero <±1.5% of product FS per sensor; TC Span<±1.5% of product FS per sensor (2 sensors per unit)
Media Temp Limits -4 to 185±F (-20 to 85±C); 0 to 90% RH non-condensing
Click here for complete specifications on the Veris PWLX05S

What's included with the Veris PWLX05S

  • Veris PWLX05S Wet Media Differential Pressure Transducer, 0 to 250 psig

Ask a question about Veris PWLX05S Wet Media Differential Pressure Transducer, 0 to 250 psig

Customer Reviews for the Veris PWLX05S

Veris PWLX05S Offers

The wet media differential pressure transducer is ideal for measuring pressure across pumps, filters, heat exchangers, compressors and other non-corrosive wet media applications.

Features

  • Jumper-selectable output switch for normal (4 to 20 mA) or reverse (20 to 4 mA) operation provides application flexibility
  • Rugged, die-cast enclosure provides NEMA 4 sealing
  • Jumper-controlled electronic surge dampening for high stability
  • Push-button zero calibration ensures there are no trim pots to adjust
  • Lowest total installed cost
  • Jumper-selectable port swap feature eliminates costly replumbing when the high and low ports are improperly plumbed; simply change the jumper position from normal to swap and problem solved!
  • Dual sensor design eliminates the requirement for a bypass valve assembly in most applications
  • Switch-selectable pressure ranges means fewer models to order and stock
  • Push-button and remote zero adjustment help maintain accuracy and prevent callbacks with automatic zero calibration

Applications

  • Monitoring and Controlling Pump Differential Pressure
  • Chiller/Boiler Differential Pressure Drop
  • CW/HW System Differential Pressure

Veris PWLX05S Specifications

Input Power 12 to 30 V DC/24 VAC nominal
Maximum Current Draw DC: 125 mA; AC: 280 mA
Output 3-wire transmitter; user selectable 4 to 20 mA, (clipped and capped)/0 to 5 V/0 to 10 V
Surge Damping Electronic; 5-second averaging
Accuracy At 77°C (25°C): ±1% FS (range A, B, C), ±2% FS (range D)
Test Mode Overrides output to full-scale (20 mA, 5 V, 10 V)
Pressure Range (Selectable) 0 to 10/20/50/100 psid (0 to 0.34/0.69/1.72/3.45 bar)
Product Operating Environment -140 to 130°F (-10 to 55°C); 0 to 90% RH, non-condensing
Long Term Stability ±0.25% per year
Zero Adjust Push-button auto-zero and digital input (2-pos terminal block)
Status Indication Dual-color LED: green = normal, green blinking = low > high, red = over-range, red blinking = over-pressure
Housing Material White powder-coat aluminum
Media Compatibility Media compatible with 17 to 4 PH stainless steel
Proof Pressure Max 2 x FS range
Burst Pressure Max 5 x FS range
Temperature Compensated Range 32 to 122°F (0 to 50°C); TC Zero <±1.5% of product FS per sensor; TC Span<±1.5% of product FS per sensor (2 sensors per unit)
Media Temp Limits -4 to 185±F (-20 to 85±C); 0 to 90% RH non-condensing
Click here for complete specifications on the Veris PWLX05S

What's included with the Veris PWLX05S

  • Veris PWLX05S Wet Media Differential Pressure Transducer, 0 to 250 psig

Ask a question about Veris PWLX05S Wet Media Differential Pressure Transducer, 0 to 250 psig

Customer Reviews for the Veris PWLX05S

More Veris Products

Calibration Lab