Veris E50H2 DIN Rail Mount Energy Meter

Model: E50H2

Veris E50H2 DIN Rail Mount Energy Meter

Model: E50H2

DIN Rail Mount Energy Meter with BACNET communications, one alarm output and one pulse input.

DIN Rail Mount Energy Meter with BACNET communications, one alarm output and one pulse input.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Schneider Electric METSEEM3561 Picture PowerLogic EM3500 DIN rail meter - BACnet without logging - current transformer-

Schneider Electric METSEEM3561 Picture PowerLogic EM3500 DIN rail meter - BACnet without logging - current transformer

Model: METSEEM3561

The EM3500 series offers a three-phase DIN rail-mounted energy meter designed for accurate cost allocation and sub-metering with low voltage current transducers, providing ANSI C12.20 accuracy of 0.2%. Suitable for 230V AC networks, these meters are compliant with UL508, CSA 22.2, and EN 61010-1 standards, featuring Native BACnet and pulse inputs for simple wage sensor integration.


Veris E50H2 Offers

Features

  • DIN rail mounting option
  • Easy installation
  • ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S
  • Great for cost allocation
  • Real energy output and phase loss alarm output
  • One device serves multiple applications
  • 90 to 600 VAC
  • Application versatility with fewer models to stock
  • Bright backlit LCD
  • Easy visibility in dark enclosures
  • Compatible with CT's from 5 A to 32000 A
  • Wide range of service types
  • User-enabled password protection
  • +E528 System integration via Modbus RTU
  • Convenient compatibility with existing systems

Applications

  • Energy monitoring in building automation systems
  • Renewable energy
  • Energy management
  • Commercial sub-metering
  • Industrial monitoring
  • Cost allocation

Veris E50H2 Specifications

Inputs
AC Control Power 50/60 Hz; 5 VA maximum; 90 V minute; UL maximums: 600 V L-L (347 V L-N); CE maximums: 300 V L-N (520 V L-L)
DC Control Power 3W maximum; UL and CE: 125 to 300 VDC (external DC current limiting required)
Voltage Input UL: 90 V L-N to 600 V L-L
CE: 90 V L-N to 300 V L-L
Current Input Scaling 5 A to 32,000 A
Input Range 0 to 0.333 V or 0 to 1 V (selectable)
Accuracy
Real Power and Energy 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5 S)
Outputs
Real Energy Pulse N.O. Static
Alarm Contacts N.C. Static
Mechanical
Mounting DIN Rail or 3-point screw mount, NEMA 4 enclosure optional
Environmental
Operating Temperature Range -30 to 70°C (-22 to 158°F)
Storage Temperature Range -40 to 85°C (-40 to 185°F)
Humidity Range <95% Relative Humidity, Non-Condensing
Click here for complete specifications on the Veris E50H2

What's included with the Veris E50H2

  • Veris E50H2 DIN Rail Mount Energy Meter

Ask a question about Veris E50H2 DIN Rail Mount Energy Meter

Customer Reviews for the Veris E50H2

Veris E50H2 Offers

Features

  • DIN rail mounting option
  • Easy installation
  • ANSI 12.20 0.2% accuracy, IEC 62053-22 Class 0.2S
  • Great for cost allocation
  • Real energy output and phase loss alarm output
  • One device serves multiple applications
  • 90 to 600 VAC
  • Application versatility with fewer models to stock
  • Bright backlit LCD
  • Easy visibility in dark enclosures
  • Compatible with CT's from 5 A to 32000 A
  • Wide range of service types
  • User-enabled password protection
  • +E528 System integration via Modbus RTU
  • Convenient compatibility with existing systems

Applications

  • Energy monitoring in building automation systems
  • Renewable energy
  • Energy management
  • Commercial sub-metering
  • Industrial monitoring
  • Cost allocation

Veris E50H2 Specifications

Inputs
AC Control Power 50/60 Hz; 5 VA maximum; 90 V minute; UL maximums: 600 V L-L (347 V L-N); CE maximums: 300 V L-N (520 V L-L)
DC Control Power 3W maximum; UL and CE: 125 to 300 VDC (external DC current limiting required)
Voltage Input UL: 90 V L-N to 600 V L-L
CE: 90 V L-N to 300 V L-L
Current Input Scaling 5 A to 32,000 A
Input Range 0 to 0.333 V or 0 to 1 V (selectable)
Accuracy
Real Power and Energy 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5 S)
Outputs
Real Energy Pulse N.O. Static
Alarm Contacts N.C. Static
Mechanical
Mounting DIN Rail or 3-point screw mount, NEMA 4 enclosure optional
Environmental
Operating Temperature Range -30 to 70°C (-22 to 158°F)
Storage Temperature Range -40 to 85°C (-40 to 185°F)
Humidity Range <95% Relative Humidity, Non-Condensing
Click here for complete specifications on the Veris E50H2

What's included with the Veris E50H2

  • Veris E50H2 DIN Rail Mount Energy Meter

Ask a question about Veris E50H2 DIN Rail Mount Energy Meter

Customer Reviews for the Veris E50H2

More Veris Products