Offers a unique solution for measuring energy data, this meter features maximum flexibility for retrofit applications. Provides innovative three-phase networked (Modbus RTU and BACnet MS/TP) power transducers that calibrate measurement electronics, high accuracy 400 A industrial-grade CTs, and fusing protection in a single package.
Offers a unique solution for measuring energy data, this meter features maximum flexibility for retrofit applications. Provides innovative three-phase networked (Modbus RTU and BACnet MS/TP) power transducers that calibrate measurement electronics, high accuracy 400 A industrial-grade CTs, and fusing protection in a single package.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Plug-In Power Meters category for similar products.
Or let's do a search and help you find what you need:
Features
Applications
| Measurement Accuracy | |
| Real Power and Energy | 1/3 V current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1% Rogowski current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1% |
| Reactive Power and Energy | IEC 62053-24 Class 1, 1% |
| System Accuracy | 1% |
| Input Voltage | |
| Measured AC Voltage | Minimum 90 VL-N (156 VL-L) for stated accuracy; UL maximum: 480 VL-L (277 VL-N); CE maximum: 300 VL-N |
| Impedance | 2.5 MΩL-N/5 MΩL-L |
| Frequency Range | 45 to 65 Hz |
| Input Current | |
| Measurement Input Range | 0 to 0.333 VAC (+20% over-range) |
| Impedance | 33 kΩ |
| Control Power | |
| AC | AC: Drawn from phase A-B line-to-line voltage input; 4 VA maximum: 90 VL-N minimum; UL maximum: 480 VL-L (277 VL-N); CE maximum: 300 VL-N |
| Ride-through Time | 50 ms at 120 VAC |
| General Specifications | |
| Ingress Protection (IEC 60529) | IP20 |
| Plug Wire Size (I/O, Communications, CT) | 24 to 16 AWG (0.2 to 1.5 mm2) |
| CT Rating | 1000 VAC basic insulation rating, 600 VAC reinforced insulation rating |
| Environmental Conditions | Operating temperature: 32 to 158°F (0 to 70°C) Storage temperature: -40 to 185°F (-40 to 85°C) Humidity range: <95% RH (non-condensing) Altitude: 1.86 mi (3 km) maximum Pollution degree: 2 |
| CT Size | 3-phase, 3-wire, 400 A, split-core small |
| Measurement Accuracy | |
| Real Power and Energy | 1/3 V current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1% Rogowski current input mode: IEC 62053-21 Class 1S, ANSI C12.1, 1% |
| Reactive Power and Energy | IEC 62053-24 Class 1, 1% |
| System Accuracy | 1% |
| Input Voltage | |
| Measured AC Voltage | Minimum 90 VL-N (156 VL-L) for stated accuracy; UL maximum: 480 VL-L (277 VL-N); CE maximum: 300 VL-N |
| Impedance | 2.5 MΩL-N/5 MΩL-L |
| Frequency Range | 45 to 65 Hz |
| Input Current | |
| Measurement Input Range | 0 to 0.333 VAC (+20% over-range) |
| Impedance | 33 kΩ |
| Control Power | |
| AC | AC: Drawn from phase A-B line-to-line voltage input; 4 VA maximum: 90 VL-N minimum; UL maximum: 480 VL-L (277 VL-N); CE maximum: 300 VL-N |
| Ride-through Time | 50 ms at 120 VAC |
| General Specifications | |
| Ingress Protection (IEC 60529) | IP20 |
| Plug Wire Size (I/O, Communications, CT) | 24 to 16 AWG (0.2 to 1.5 mm2) |
| CT Rating | 1000 VAC basic insulation rating, 600 VAC reinforced insulation rating |
| Environmental Conditions | Operating temperature: 32 to 158°F (0 to 70°C) Storage temperature: -40 to 185°F (-40 to 85°C) Humidity range: <95% RH (non-condensing) Altitude: 1.86 mi (3 km) maximum Pollution degree: 2 |
| CT Size | 3-phase, 3-wire, 400 A, split-core small |