Veris CW2LAXA Air Quality Sensor

Model: CW2LAXA

Veris CW2LAXA Air Quality Sensor

Model: CW2LAXA

Designed to measure CO2 and temperature, this wall-mounted sensor plays a crucial role in maintaining indoor air quality across various applications, ensuring environments are safe and comfortable for occupants.

Designed to measure CO2 and temperature, this wall-mounted sensor plays a crucial role in maintaining indoor air quality across various applications, ensuring environments are safe and comfortable for occupants.

Sale Price $235.39 USD
Regular Price $910.91 USD
Availability 1 to 2 Weeks
Quantity

Veris CW2LAXA Offers

This air quality sensor for rooms is a flexible multi-sensor platform for use with BAS controllers that is designed to accept 4 to 20 mA, 0 to 5 VDC or 0 to 10 VDC outputs. This sensor includes include both temperature and CO2 elements and the user interface is assured by an LCD screen with 3 control buttons.

Features

  • Microprocessor controlled for excellent stability
  • CO2 and temperature sensors
  • High CO2 accuracy using non-dispersive infrared (NDIR) diffusion sampling
  • Solid-state, integrated circuit temperature sensor
  • Field-selectable outputs for operation flexibility
  • Self-calibrating for easy maintenance
  • LCD screen with three control buttons
  • Easy installation with snap-on covers and security screw

Applications

  • Controlling ventilation in response to accuracy
  • ASHRAE 62.1 compliance
  • Office buildings, conference rooms, schools, retail stores, etc.

Veris CW2LAXA Specifications

CO2 Measurement Accuracy  ±30 ppm ±3% of measured value
CO2 Measurement Range  0 to 2000/5000 ppm (selectable)
CO2 Measurement Repeatability  ±20 ppm ±1% of measured value
CO2 Measurement Resolution  1 ppm
CO2 Response Time  <60 seconds for 90% step change
CO2 Sensor Type  Non-dispersive infrared (NDIR), diffusion sampling
Display Size  2.05 in (52 mm)
Display Type  Segmented LCD, with 3 Buttons
Electrical Wiring Size  Screw terminals, 18-24 AWG
IP Protection  IP20
Input Specifications  Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz
Operating Humidity  0 to 95% RH non-condensing
Operating Temperature  0 to 50 °C (32 to 122 °F)
Output Specifications  Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V
Outputs   Analog
Setpoint Range  Temperature: 0 to 50 °C (32 to 122 °F) / 10 to 35 °C (50 to 95 °F), selectable Fan Speed: Off, Low, Med., High.
Setpoint Specifications  0-10Vdc. Temperature or fan speed (one setpoint type is selectable via dip switch)
Standards EMC  EN61000 Series - industrial immunity
Standards  CE, UL 916, RCM, ICES-003. REACH, RoHS
Temperature Measurement Accuracy  ±0.2 °C (±0.4 °F) typical
Temperature Measurement Range  0 to 50 °C (32 to 122 °F)
Temperature Measurement Resolution  0.1 °C (0.1 °F)
Temperature Sensor Type  Solid state, integrated circuit
Click here for complete specifications on the Veris CW2LAXA

What's included with the Veris CW2LAXA

  • Veris CW2LAXA Air Quality Sensor

Ask a question about Veris CW2LAXA Air Quality Sensor

Customer Reviews for the Veris CW2LAXA

Veris CW2LAXA Offers

This air quality sensor for rooms is a flexible multi-sensor platform for use with BAS controllers that is designed to accept 4 to 20 mA, 0 to 5 VDC or 0 to 10 VDC outputs. This sensor includes include both temperature and CO2 elements and the user interface is assured by an LCD screen with 3 control buttons.

Features

  • Microprocessor controlled for excellent stability
  • CO2 and temperature sensors
  • High CO2 accuracy using non-dispersive infrared (NDIR) diffusion sampling
  • Solid-state, integrated circuit temperature sensor
  • Field-selectable outputs for operation flexibility
  • Self-calibrating for easy maintenance
  • LCD screen with three control buttons
  • Easy installation with snap-on covers and security screw

Applications

  • Controlling ventilation in response to accuracy
  • ASHRAE 62.1 compliance
  • Office buildings, conference rooms, schools, retail stores, etc.

Veris CW2LAXA Specifications

CO2 Measurement Accuracy  ±30 ppm ±3% of measured value
CO2 Measurement Range  0 to 2000/5000 ppm (selectable)
CO2 Measurement Repeatability  ±20 ppm ±1% of measured value
CO2 Measurement Resolution  1 ppm
CO2 Response Time  <60 seconds for 90% step change
CO2 Sensor Type  Non-dispersive infrared (NDIR), diffusion sampling
Display Size  2.05 in (52 mm)
Display Type  Segmented LCD, with 3 Buttons
Electrical Wiring Size  Screw terminals, 18-24 AWG
IP Protection  IP20
Input Specifications  Class 2; 20 to 30 Vdc, 24 Vac, 50 to 60 Hz
Operating Humidity  0 to 95% RH non-condensing
Operating Temperature  0 to 50 °C (32 to 122 °F)
Output Specifications  Selectable 4 to 20 mA, 0 to 5 V, 0 to 10 V
Outputs   Analog
Setpoint Range  Temperature: 0 to 50 °C (32 to 122 °F) / 10 to 35 °C (50 to 95 °F), selectable Fan Speed: Off, Low, Med., High.
Setpoint Specifications  0-10Vdc. Temperature or fan speed (one setpoint type is selectable via dip switch)
Standards EMC  EN61000 Series - industrial immunity
Standards  CE, UL 916, RCM, ICES-003. REACH, RoHS
Temperature Measurement Accuracy  ±0.2 °C (±0.4 °F) typical
Temperature Measurement Range  0 to 50 °C (32 to 122 °F)
Temperature Measurement Resolution  0.1 °C (0.1 °F)
Temperature Sensor Type  Solid state, integrated circuit