Work with full HVAC/R functionality and advanced features like DC amps, LRA inrush, differential temperature, and wireless connection to a free app for logging, graphing, and emailing results with this wireless TRMS clamp meter. In addition, this meter features a three-phase and unbalanced motor test, 600 A AC/DC, and 9999 μF.
Work with full HVAC/R functionality and advanced features like DC amps, LRA inrush, differential temperature, and wireless connection to a free app for logging, graphing, and emailing results with this wireless TRMS clamp meter. In addition, this meter features a three-phase and unbalanced motor test, 600 A AC/DC, and 9999 μF.
Determine a motor's load efficiency, low Z (impedance) to improve accuracy by reducing ghost voltages, and a low pass filter to screen out unwanted higher frequencies from variable frequency drives
Features
Made better
All the pro features you love
Plus, added bonus motor tests
Applications
| DC Amps Measurement - Jaw Input* *Minimum current for clamp measurement: 0.2 A |
|
| Range | 60 A 600 A |
| Resolution | 0.01 A 0.1 A |
| Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
| Overload Protection | 600 V RMS |
| AC Amps Measurement - Jaw Input* *45 to 400 Hz True RMS *Minimum current for clamp measurement: 0.3 A |
|
| Range | 60 A 600 A |
| Resolution | 0.01 A 0.1 A |
| Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
| Overload Protection | 600 V RMS |
| DC Low Amps Measurement - Test Lead Input | |
| Range | 600 uA 2000 u A |
| Resolution | 0.1 uA 1 uA |
| Accuracy | ±1.2% + 3 digits |
| Overload Protection | 600 V RMS |
| AC Low Amps Measurement - Test Lead Input* *45 to 400 Hz true RMS |
|
| Range | 600 uA 2000 u A |
| Resolution | 0.1 uA 1 uA |
| Accuracy | ±1.5% + 3 digits |
| Overload Protection | 600 V RMS |
| DC Volts Measurement | |
| Range | 600 mV 6 V 60 V 600 V 1000 V |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
| Accuracy | ±0.5% + 4 digits ±0.8% + 5 digits |
| Overload Protection | 1000 V RMS |
| AC Volts Measurement* *45 to 400 Hz true RMS |
|
| Range | 600 mV 6 V 60 V 600 V 1000 V |
| AC Volts Measurement | |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
| Accuracy | ±1% + 3 digits |
| Overload Protection | 1000 V RMS |
| Ohms Measurement | |
| Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 Mω |
| Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
| Accuracy | ±0.8% + 3 digits ±1.2% + 3 digits |
| Overload Protection | 600 V RMS |
| Diode Test | |
| Range | 3.1 V |
| Open Circuit Voltage | <3.2 V DC |
| Test Current (Typical) | 0.25 mA |
| Overload Protection | 600 V RMS |
| Capacitance Measurement | |
| Range | 10 nF 100 nF 1 uF 10 uF 100 uF 9999 uF |
| Resolution | 0.01 bF 0.1 nF 0.001 uF 0.01 uF 0.1 uF 1 uF |
| Accuracy | 2.5% + 5 digits 3% + 5 digits |
| Overload Protection | 600 V RMS |
| Temperature Measurement* *Sensor: "K" type thermocouple, sensor accuracy not included |
|
| Range | -328 to 999°F -200 to 999°C 1000 to 2462°F 1000 to 1350°C |
| Resolution | 0.1°F 0.1°C 1°F 1°C |
| Accuracy | ±(1% + 3.6°F) ±(1% + 2°C) ±(1% + 3°F) ±(1% + 2°C) |
| Overload Protection | 30 V RMS |
| Frequency Measurement - Test Lead Input* *Sensitivity: 1.8 Vrms |
|
| Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
| Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
| Accuracy | 0.1% + 3 digits |
| Overload Protection | 1000 V RMS |
| Frequency Measurement - Jaw Input | |
| Range | 999.9 Hz 1999 Hz |
| Resolution | 0.1 Hz 1 Hz |
| Accuracy | 0.5% + 5 digits |
| Overload Protection | 600 V RMS |
| Duty(%) Cycle Measurement | |
| Range | 1 to 99% |
| Accuracy | ±(0.2% per kHz + 0.1% + 5 digits) |
| Overload Protection | 1000 V RMS |
| Audible Continuity Measurement | |
| Open Circuit Voltage <1 | Threshold Approximate: <40 Ω |
| Overload Protection | 600 V RMS |
| General Specifications | |
| Display | 3 ⅚ digits 6000 count |
| Back Light | Yes |
| Refresh Rate | 3/second |
| Over Range | "OL" is displayed |
| Apo | Auto power off after 30 minutes of use |
| Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) |
| Operating Humidity | <80% |
| Test Leads | Test leads with alligator clips and back probes Use ATL58 test leads with ABP3 back probes and AAC3 alligator clips ATL55, ATL57 and ATLTX will not work with DL599 |
| Battery Type | 4 x AAA |
| Pollution Degree | 2 |
| CAT Rating | CATIV 600 V |
| RoHS | Yes |
| FCC/IC Compliant | FCC |
| Certifications | cETLus UL 61010-1: 2012, IP42, 6' drop protection |
| Dimensions | 9.45 x 2.58 x 1.67" (240.03 x 65.52 x 42.42 mm) |
| Weight | 0.926 lbs (0.42 kg) |
Click on a category to view a selection of compatible accessories with the UEi DL599 Wireless TRMS Clamp Meter with three-phase and unbalance motor tests, 600 A AC/DC, 9999 μF.
| DC Amps Measurement - Jaw Input* *Minimum current for clamp measurement: 0.2 A |
|
| Range | 60 A 600 A |
| Resolution | 0.01 A 0.1 A |
| Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
| Overload Protection | 600 V RMS |
| AC Amps Measurement - Jaw Input* *45 to 400 Hz True RMS *Minimum current for clamp measurement: 0.3 A |
|
| Range | 60 A 600 A |
| Resolution | 0.01 A 0.1 A |
| Accuracy | ±2% + 5 digits ±1.8% + 5 digits |
| Overload Protection | 600 V RMS |
| DC Low Amps Measurement - Test Lead Input | |
| Range | 600 uA 2000 u A |
| Resolution | 0.1 uA 1 uA |
| Accuracy | ±1.2% + 3 digits |
| Overload Protection | 600 V RMS |
| AC Low Amps Measurement - Test Lead Input* *45 to 400 Hz true RMS |
|
| Range | 600 uA 2000 u A |
| Resolution | 0.1 uA 1 uA |
| Accuracy | ±1.5% + 3 digits |
| Overload Protection | 600 V RMS |
| DC Volts Measurement | |
| Range | 600 mV 6 V 60 V 600 V 1000 V |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
| Accuracy | ±0.5% + 4 digits ±0.8% + 5 digits |
| Overload Protection | 1000 V RMS |
| AC Volts Measurement* *45 to 400 Hz true RMS |
|
| Range | 600 mV 6 V 60 V 600 V 1000 V |
| AC Volts Measurement | |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
| Accuracy | ±1% + 3 digits |
| Overload Protection | 1000 V RMS |
| Ohms Measurement | |
| Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 Mω |
| Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
| Accuracy | ±0.8% + 3 digits ±1.2% + 3 digits |
| Overload Protection | 600 V RMS |
| Diode Test | |
| Range | 3.1 V |
| Open Circuit Voltage | <3.2 V DC |
| Test Current (Typical) | 0.25 mA |
| Overload Protection | 600 V RMS |
| Capacitance Measurement | |
| Range | 10 nF 100 nF 1 uF 10 uF 100 uF 9999 uF |
| Resolution | 0.01 bF 0.1 nF 0.001 uF 0.01 uF 0.1 uF 1 uF |
| Accuracy | 2.5% + 5 digits 3% + 5 digits |
| Overload Protection | 600 V RMS |
| Temperature Measurement* *Sensor: "K" type thermocouple, sensor accuracy not included |
|
| Range | -328 to 999°F -200 to 999°C 1000 to 2462°F 1000 to 1350°C |
| Resolution | 0.1°F 0.1°C 1°F 1°C |
| Accuracy | ±(1% + 3.6°F) ±(1% + 2°C) ±(1% + 3°F) ±(1% + 2°C) |
| Overload Protection | 30 V RMS |
| Frequency Measurement - Test Lead Input* *Sensitivity: 1.8 Vrms |
|
| Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
| Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
| Accuracy | 0.1% + 3 digits |
| Overload Protection | 1000 V RMS |
| Frequency Measurement - Jaw Input | |
| Range | 999.9 Hz 1999 Hz |
| Resolution | 0.1 Hz 1 Hz |
| Accuracy | 0.5% + 5 digits |
| Overload Protection | 600 V RMS |
| Duty(%) Cycle Measurement | |
| Range | 1 to 99% |
| Accuracy | ±(0.2% per kHz + 0.1% + 5 digits) |
| Overload Protection | 1000 V RMS |
| Audible Continuity Measurement | |
| Open Circuit Voltage <1 | Threshold Approximate: <40 Ω |
| Overload Protection | 600 V RMS |
| General Specifications | |
| Display | 3 ⅚ digits 6000 count |
| Back Light | Yes |
| Refresh Rate | 3/second |
| Over Range | "OL" is displayed |
| Apo | Auto power off after 30 minutes of use |
| Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) |
| Operating Humidity | <80% |
| Test Leads | Test leads with alligator clips and back probes Use ATL58 test leads with ABP3 back probes and AAC3 alligator clips ATL55, ATL57 and ATLTX will not work with DL599 |
| Battery Type | 4 x AAA |
| Pollution Degree | 2 |
| CAT Rating | CATIV 600 V |
| RoHS | Yes |
| FCC/IC Compliant | FCC |
| Certifications | cETLus UL 61010-1: 2012, IP42, 6' drop protection |
| Dimensions | 9.45 x 2.58 x 1.67" (240.03 x 65.52 x 42.42 mm) |
| Weight | 0.926 lbs (0.42 kg) |
Click on a category to view a selection of compatible accessories with the UEi DL599 Wireless TRMS Clamp Meter with three-phase and unbalance motor tests, 600 A AC/DC, 9999 μF.