has a temperature of (thermocouple probe) 14 to 752°F (-10 to 400°C). Themocouple temperature (Pipe clamp adapter) -40 to 250°F (-40 to 121°C).
has a temperature of (thermocouple probe) 14 to 752°F (-10 to 400°C). Themocouple temperature (Pipe clamp adapter) -40 to 250°F (-40 to 121°C).
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
UEi DL479COMBO has an audible continuity and non-contact voltage detection.
Features
Applications
| AC Amps - Jaw Input | |
| Range | 60 to 600 A |
| Resolution | 0.01 to 0.1 A |
| Accuracy | ±(2.0% + 8 dgts) |
| Overload Protections | 600 V RMS |
| AC Volts (45 to 400 Hz) | |
| Range | 600 mV to 750 V |
| Resolution | 0.1 mV to 1.0 V |
| Accuracy | ±(1.0% + 3 dgts) |
| Overload Protection | 1000V RMS |
| DC Volts | |
| Range | 600 mV to 600V |
| Resolution | 1 to 100 mV |
| Accuracy | ±(0.5% + 4 dgts) |
| Overload Protection | 1000V RMS |
| AC Amps - Jaw Input | |
| Range | 60 to 600 A |
| Resolution | 0.01 to 0.1 A |
| Accuracy | ±(2.0% + 8 dgts) |
| Overload Protections | 600 V RMS |
| AC Volts (45 to 400 Hz) | |
| Range | 600 mV to 750 V |
| Resolution | 0.1 mV to 1.0 V |
| Accuracy | ±(1.0% + 3 dgts) |
| Overload Protection | 1000V RMS |
| DC Volts | |
| Range | 600 mV to 600V |
| Resolution | 1 to 100 mV |
| Accuracy | ±(0.5% + 4 dgts) |
| Overload Protection | 1000V RMS |