Ideal for applications where flexibility and control are critical, this counter comes with an RS485 interface and MODBUS and CR/LF protocol for interfacing with other equipment. In addition, it can be used as a preset/batch counter or totalizer and features dual relays and a backlit display with user-friendly front keys.
Ideal for applications where flexibility and control are critical, this counter comes with an RS485 interface and MODBUS and CR/LF protocol for interfacing with other equipment. In addition, it can be used as a preset/batch counter or totalizer and features dual relays and a backlit display with user-friendly front keys.
Counter, tachometer, timer, and position display in a single unit, this counter can be used as a preset counter, batch counter, or totalizer, depending on requirements, with automatic help text to take the user through programming. In addition, values are clear and legible on the 14 LED segments, and the large, user-friendly front keys are accessible even when wearing gloves.
Features
Applications
Outputs | Switching voltage maximum: 250 V AC/150 V DC Switching current: Maximum: 3 A AC/DC; minimum: 30 mA DC Switching capacity maximum: 750 VA/90 W Output 1 + 2 Mechanical service life (switching cycles): 2 x 107 No. of switching cycles at 3 A/250 V AC: 5 x 104 No. of switching cycles at 3 A/30 V DC: 5 x 104 Reaction time of the outputs: 13 ms |
Count Inputs | A and B |
Polarity of the Inputs | Programmable for all inputs in common, NPN/PNP |
Input Resistance | 5 kΩ |
Count Frequency | Pulse counters: Maximum 55 kHz Tachometers: Maximum 65 kHz Can be damped to 30 Hz (mechanical contacts) |
Control/Reset Input | MPI 1 and MPI 2, Lock, Gate, Reset |
Minimum Pulse Duration of the Inputs | 10 ms/1 ms |
Switching Levels | AC supply: 4 to 30 V DC; 0 to 2 V DC (low), 3.5 to 30 V DC (high) DC supply: 1 to 30 V DC; 0 to 2 V DC (low), 3.5 to 30 V DC (high) |
Pulse Shape | Variable, Schmitt-Trigger characteristics |
External Fuse Protection | 230 V AC T0.1 A 10 to 30 V DC T 0.25 A |
Data Retention | >10 years, EEPROM |
Response Time of the Frequency Meter | 100/600 ms |
Input Modes | Frequency meter: A, A-B, A+B quad, A/B, (A-B)/A x 100% Timer: 4 start modes: FrErun, Auto, InpA.InpB., InpB.InpB. Pulse counter: Count direction (cnt.dir) Difference (up.dn) Addition A+B (up.up) Phase discriminator x1, x2, x4 (quad, quad x2, quad x4) Ratio (A/B) Ratio in % ((A-B)/Ax100%) |
Interface | RS485 |
Display | 6-digit red 14 segment LED display, 0.55" (14 mm) high |
Environmental | Operating temperature: -4 to 149°F (-20 to 65°C), non-condensing Storage temperature -13 to 167°F (-25 to 5°C) Relative humidity (at 104°F [40°C]): 93% RH (non-condensing) Altitude: Up to 6562’ (2000 m) |
Power Supply | AC 100 to 240 V AC, +10% maximum 11 VA, 50/60 Hz Sensor: 24 VDC +15%, 80 mA (AC supply); maximum 80 mA, external power supply is connected through (DC supply) |
EMC | Emitted interference: EN55011 class B Immunity to interference: EN 61000-6-2 |
Safety | Designed to EN 61010 part 1 Protected class 3 Application area pollution level 2 |
Protection | IP65 (from the front) |
Dimensions | 3.77 x 1.88 x 4" (96 x 48 x 101.7 mm) |
Weight | Approximately 6.35 oz (180 g) |
Outputs | Switching voltage maximum: 250 V AC/150 V DC Switching current: Maximum: 3 A AC/DC; minimum: 30 mA DC Switching capacity maximum: 750 VA/90 W Output 1 + 2 Mechanical service life (switching cycles): 2 x 107 No. of switching cycles at 3 A/250 V AC: 5 x 104 No. of switching cycles at 3 A/30 V DC: 5 x 104 Reaction time of the outputs: 13 ms |
Count Inputs | A and B |
Polarity of the Inputs | Programmable for all inputs in common, NPN/PNP |
Input Resistance | 5 kΩ |
Count Frequency | Pulse counters: Maximum 55 kHz Tachometers: Maximum 65 kHz Can be damped to 30 Hz (mechanical contacts) |
Control/Reset Input | MPI 1 and MPI 2, Lock, Gate, Reset |
Minimum Pulse Duration of the Inputs | 10 ms/1 ms |
Switching Levels | AC supply: 4 to 30 V DC; 0 to 2 V DC (low), 3.5 to 30 V DC (high) DC supply: 1 to 30 V DC; 0 to 2 V DC (low), 3.5 to 30 V DC (high) |
Pulse Shape | Variable, Schmitt-Trigger characteristics |
External Fuse Protection | 230 V AC T0.1 A 10 to 30 V DC T 0.25 A |
Data Retention | >10 years, EEPROM |
Response Time of the Frequency Meter | 100/600 ms |
Input Modes | Frequency meter: A, A-B, A+B quad, A/B, (A-B)/A x 100% Timer: 4 start modes: FrErun, Auto, InpA.InpB., InpB.InpB. Pulse counter: Count direction (cnt.dir) Difference (up.dn) Addition A+B (up.up) Phase discriminator x1, x2, x4 (quad, quad x2, quad x4) Ratio (A/B) Ratio in % ((A-B)/Ax100%) |
Interface | RS485 |
Display | 6-digit red 14 segment LED display, 0.55" (14 mm) high |
Environmental | Operating temperature: -4 to 149°F (-20 to 65°C), non-condensing Storage temperature -13 to 167°F (-25 to 5°C) Relative humidity (at 104°F [40°C]): 93% RH (non-condensing) Altitude: Up to 6562’ (2000 m) |
Power Supply | AC 100 to 240 V AC, +10% maximum 11 VA, 50/60 Hz Sensor: 24 VDC +15%, 80 mA (AC supply); maximum 80 mA, external power supply is connected through (DC supply) |
EMC | Emitted interference: EN55011 class B Immunity to interference: EN 61000-6-2 |
Safety | Designed to EN 61010 part 1 Protected class 3 Application area pollution level 2 |
Protection | IP65 (from the front) |
Dimensions | 3.77 x 1.88 x 4" (96 x 48 x 101.7 mm) |
Weight | Approximately 6.35 oz (180 g) |