Measure the atmospheres CO2, temperature, relative humidity, dew point, wet bulb, CO, and calculate percentage in the outside air.
Measure the atmospheres CO2, temperature, relative humidity, dew point, wet bulb, CO, and calculate percentage in the outside air.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Designed for ease of use and to provide the user with the measurements needed to monitor and later make adjustments to keep a safe work environment.
Applications
CO2 Function | |
Range | 0 to 5000ppm |
Accuracy | 50~104°F: ±5% of rdg+75ppm <50°F, >104°F: ±10% of rdg+75ppm |
Temperature Function | |
Range | -5 to 140°F -20 to 60°C |
Accuracy | ±2°F ±1°C |
Dew Point Temperature Function | |
Range | -47 to 135°F -44 to 57°C |
Accuracy | Calculation ±1°C |
Wet Bulb Temperature Function | |
Range | 3 to 135°F -16 to 57°C |
Accuracy | Calculation |
Relative Humidity Function | |
Range | 5% to 95% |
Accuracy | ±2°F ±1°C |
% Outside Air Function | |
Range | 0 to 100% |
Accuracy | Calculation |
CO Function | |
Range | 0 to 500ppm |
Accuracy | ±3ppm or ±5% of rdg whichever is greater |
Data Logging | Up to 4,000 samples 1 sec to 23hr 59min interval |
Display Type | 3 line with annunciators and backlight |
CO2 Alarm | Audible and visual, selectable level (factory default 30ppm) |
Operating Temperature & Humidity | CO and CO2: 14 to 122°F (-10 to 50°C) All Other Function: -4 to 140°F (-20 to 60°C) Humidity 15 ~ 95% non-condensing |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Power supply | 3 AA batteries ( 4.5V) AC/DC adapter 5Vout (Center positive) Battery Life: 40 hours typical without backlight |
Output | Serial output via USB connection Infrared output to optional A740 printer/td> |
CO2 Function | |
Range | 0 to 5000ppm |
Accuracy | 50~104°F: ±5% of rdg+75ppm <50°F, >104°F: ±10% of rdg+75ppm |
Temperature Function | |
Range | -5 to 140°F -20 to 60°C |
Accuracy | ±2°F ±1°C |
Dew Point Temperature Function | |
Range | -47 to 135°F -44 to 57°C |
Accuracy | Calculation ±1°C |
Wet Bulb Temperature Function | |
Range | 3 to 135°F -16 to 57°C |
Accuracy | Calculation |
Relative Humidity Function | |
Range | 5% to 95% |
Accuracy | ±2°F ±1°C |
% Outside Air Function | |
Range | 0 to 100% |
Accuracy | Calculation |
CO Function | |
Range | 0 to 500ppm |
Accuracy | ±3ppm or ±5% of rdg whichever is greater |
Data Logging | Up to 4,000 samples 1 sec to 23hr 59min interval |
Display Type | 3 line with annunciators and backlight |
CO2 Alarm | Audible and visual, selectable level (factory default 30ppm) |
Operating Temperature & Humidity | CO and CO2: 14 to 122°F (-10 to 50°C) All Other Function: -4 to 140°F (-20 to 60°C) Humidity 15 ~ 95% non-condensing |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Power supply | 3 AA batteries ( 4.5V) AC/DC adapter 5Vout (Center positive) Battery Life: 40 hours typical without backlight |
Output | Serial output via USB connection Infrared output to optional A740 printer/td> |