Three Phase Industrial Device/Panel Power Metering Kit

Model: Acuvim-KL-KIT

Three Phase Industrial Device/Panel Power Metering Kit

Model: Acuvim-KL-KIT

A turn-key package for inexpensive permanent kW/kWh metering applications of a device, panel or electrical system. Features both a local LCD display and MODBUS RS485 serial communications.

A turn-key package for inexpensive permanent kW/kWh metering applications of a device, panel or electrical system. Features both a local LCD display and MODBUS RS485 serial communications.

Choose your Acuvim KL Meter

Choose your split core current transformers


Choose your options

Clear selected options



Note

The Acuvim KL was specifically designed to measure basic power (kW, kVA, kVAr) and Energy (kWh, kVAh, kVArh) if you need a meter that also measures Voltage check out the Acuvim AL.

About the Acuvim-KL

For energy and facilities professionals who need a low cost single/three phase non-revenue-grade kWh meter. Available with LCD display or DIN Rail mount transducer (no display). All models include MODBUS RS485 communications

The Acuvim-KL is an excellent, low cost meter for basic power (kW, kVA, kVAr and Energy (kWh, kVAh, kVArh) and Load Run Time. Perfect for basic sub-metering applications.


The Acuvim-L Series

The Acuvim-L series are multifunction power meters manufactured by Accuenergy. It is the ideal choice for monitoring and controlling of power distribution system.

Acuvim-L may be used as a data gathering device for an intelligent Power Distribution System or a Plant Automation System. All monitoring data is available via digital RS485 communication port running Modbus® Protocol.

The quality of the power system is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the Acuvim-L power analysis option, any phase current or voltage can be displayed and the harmonic content calculated. By knowing the harmonic distribution, action can be taken to prevent overheated transformers, motors, capacitors, neutral wires and nuisance breaker trips. Redistribution of the system loading can also be determined.


Those looking for Time of Use (TOU) features should look at the Acuvim-EL instead.


Key Features

Metering

  • Voltage V1, V2, V3, V12, V23, V31
  • Current I1, I2, I3, In
  • Power P1, P2, P3, Psum
  • Reactive Power Q1, Q2, Q3, Qsum
  • Apparent Power S1, S2, S3, Ssum
  • Frequency F
  • Power Factor PF1, PF2, PF3, PF
  • Energy Ep_imp, Ep_exp
  • Reactive Energy Eq_imp, Eq_exp
  • Apparent Energy Es
  • Demand Dmd_I1, Dmd_I2, Dmd_I3, Dmd_P, Dmd_Q, Dmd_S

Monitoring

  • Power Quality (functions not included with the Acuvim-KL)
  • Voltage Harmonics 2nd to 15th and THD( Acuvim-DL is from 2nd to 25th)
  • Current Harmonics 2nd to 15th and THD( Acuvim-DL is from 2nd to 25th)
  • Voltage Unbalance Factor U_unbl (all models excluding the Acuvim-KL)
  • Current Unbalance Factor I_unbl (all models excluding the Acuvim-KL)
  • Max/Min Statistics (all models excluding the Acuvim-KL)
  • Meter Running Time and Load Running Time (Acuvim-DL/EL/KL)

Alarms

Two (2) parameters may be set within a specified time interval. If indicated parameter is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the alarm DO output. The indicated parameter can be selected from any of the 35 parameters available.

Communication

RS485, industry standard Modbus® RTU protocol; (Only on models CL/DL/EL/KL)
Option the second RS485, Modbus® RTU protocol; or PROFIBUS-DP/V0 (available for the DL/EL Models)
Protocol. (just for Acuvim-DL/EL)

Display

Clear and large character LCD Screen display with white back light; Wide environmental temperature endurance.


Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Applications

  • Metering of distribution feeders, transformers, generators, capacitor banks and motors.
  • Medium and low voltage systems.
  • Commercial, industrial, utility.
  • Power quality analysis.

Acuvim L Series is DIN Rail Mountable

Mounting & Display Options

The Acuvim II Series is available in two mounting options:

Standard with LCD Display

The standard model is ANSI C39.1 Standard Compliant with a small size 96x96 outline.

DIN Rail Mount (Remote LCD Display Optional)

The DIN Rail compatible units are DIN 43700 Standard Compliant. The Acuvim L series also offers an optional Remote LCD display.


Acuvim L Series Typical Wiring

Typical Wiring Setups for the Acuvim L Series

Specifications

Metering
Parameters Acuvim-L Accuracy Acuvim-EL/KL Accuracy Resolution Range
Voltage 0.5% 0.5% 0.1 V 20 V to 1000 kV
Current 0.5% 0.5% 0.001 A 0 to 50000 A
Current Demand 0.5% 0.5% 0.001 A 0 to 50000 A
Power 1.0% 0.5% 1 W -9999 to 9999 MW
Reactive Power 2.0% 0.5% 1 var -9999 to 9999 Mvar
Apparent Power 1.0% 0.5% 0.001 V 0 to 9999 MVA
Power Demand 1.0% 0.5% 1 W -9999 to 9999 MW
Reactive Power Demand 2.0% 0.5% 1 var -9999 to 9999 Mvar
Apparent Power Demand 1.0% 1 VA 1 VA 0 to 9999 MVA
Power Factor 1.0% 0.5% 0.001 -1.0 to 1.0
Frequency 0.2% 0.2% 0.01 Hz 45.00 to 65.00 Hz
Energy 0.5% 0.5% 0.1 kWh 0 to 99999999.9 kWh
Reactive Energy 2.0% 0.5% 0.1 kvarh 0 to 99999999.9 kvarh
Apparent Energy 1.0% 0.5% 0.1 VAh 0 to 99999999.9 kVAh
Harmonics 2.0% - 0.01% 0 to 100.0%
Running Time 0.1 hrs 0 to 999999999.9 hrs
Communication
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Input
Current Inputs (Each Channel)
Nominal Current 5 A ac
Metering Range 0 to 6 A ac
Withstand 20 Arms continuous 100 Arms for 1 second, non-recurring
Burden 0.05 VA (typical) @ 5 Arms
Pickup Current 10 Vac
Accuracy 0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale 400 Vac L-N, 690 Vac L-L (+20%)
Withstand 1500 Vac continuous 2500 Vac, 50/60 Hz for 1 minute
Input Impedance 45 to 65 Hz
Pickup Voltage 10 Vac
Accuracy 0.5%
Energy Accuracy (Acuvim-EL)
Active (according to IEC 62053-22) Class 0.5s (according to ANSI C12.20) Class 0.5
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value 2nd to 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Control Power
Universal AC or DC
AC/DC Control Power
Operating Range 100 to 415 Vac, 50/60 Hz, 100 to 300 Vdc
Burden 3 W
Withstand 3250 Vac, 50/60 Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range 20 to 60 Vdx
Burden 3 W
Digital Output Option
Digital Output (DO) (Photo-MOS)
Voltage Range 0 to 250 Vac/dc
Load Current 100 mA (Max)
Output Frequency 25 Hz, 50% Duty Ratio
Isolation Voltage 2500 V
Digital Input Option
Digital Output (DI)
Input Voltage Range 20 to 250 Vac/dc
Input Current (Max) 2 mA
Start Voltage 15 V
Stop Voltage 5 V
Pulse Frequency (Max) 100 Hz, 50% Duty Ratio
SOE Resolution 2 ms
Operating Environment
Operation Temperature -13 to 158°F (-25 to 70°C)
Storage Temperature -40 to 185°F (-40 to 85°C)
Relative Humidity 5 to 95% non-condensing
Pollution Degree 2
Standard Compliance
Product
USA UL 61010-1
Canada cUL 61010-1
Europe IEC 61010-1
Emission
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted EN 55011
Harmonic IEC 61000-3-2
Voltage Fluctuation IEC 50081-2
Radio Interference IEC 50081-2
Immunity
ESD IEC 61000-4-2
Radiated, Radio-frequency, Electromagnetic Field IEC 61000-4-3
Electrical Fast Transient/Bust IEC 61000-4-4
Surge IEC 61000-4-5
Conducted Disturbances IEC 61000-4-6
Power Frequency Magnetic Field IEC 61000-4-8
Voltage Dips and Interruptions IEC 61000-4-11
Generic Immunity Standard for Industrial Environment EN 50082-2
Click here for complete specifications on the Accuenergy Acuvim-KL-KIT

What's included with the Accuenergy Acuvim-KL-KIT

  • Three Phase Industrial Device/Panel Power Metering Kit
  • Acuvim II Series Comparison

    Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
    Real Time Metering Phase Voltage U1, U2, U3
    Real Time Metering Line Voltage U12, U23, U31
    Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
    Real Time Metering Power P1, P2, P3, Psum
    Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
    Real Time Metering Apparent Power S1, S2, S3, Ssum
    Real Time Metering Power Factor PF1, PF2, PF3, PF
    Real Time Metering Load Nature L/C/R
    Real Time Metering Frequency F Hz
    Energy & Demand Energy Ep_imp, Ep_exp
    Energy & Demand Reactive Energy Eq_imp, Eq_exp
    Energy & Demand Apparent Energy Es
    Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
    Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
    Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
    Power Quality Voltage Unbalance U_unbl
    Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
    Power Quality Voltage THD THD_V1, THD_V2, THD_V3
    Power Quality Current THD THD_I1, THD_I2, THD_I3
    Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
    Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
    Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
    Statistics Max & Min of Voltage
    Statistics Max & Min of Current
    Hour Running Time Hour
    Hour Load Running Time Hour
    I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
    I/O Alarm Output
    Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
    Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
    Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
    Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

    Acuview Software

    As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

    Acuview Software Features

    • Simple setup feature for fast deployment and configuration Accuenergy meters.
    • Remote and real time monitoring of all meter parameters.
    • Dozens of meters can be connected to a single PC.
    • Multiple meters can be displayed and tiled in one window.
    • Real Time Data Logging.
    • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
    • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
    • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

    Customer Reviews for the Accuenergy Acuvim-KL-KIT

    Ask a question about Three Phase Industrial Device/Panel Power Metering Kit

    Note

    The Acuvim KL was specifically designed to measure basic power (kW, kVA, kVAr) and Energy (kWh, kVAh, kVArh) if you need a meter that also measures Voltage check out the Acuvim AL.

    About the Acuvim-KL

    For energy and facilities professionals who need a low cost single/three phase non-revenue-grade kWh meter. Available with LCD display or DIN Rail mount transducer (no display). All models include MODBUS RS485 communications

    The Acuvim-KL is an excellent, low cost meter for basic power (kW, kVA, kVAr and Energy (kWh, kVAh, kVArh) and Load Run Time. Perfect for basic sub-metering applications.


    The Acuvim-L Series

    The Acuvim-L series are multifunction power meters manufactured by Accuenergy. It is the ideal choice for monitoring and controlling of power distribution system.

    Acuvim-L may be used as a data gathering device for an intelligent Power Distribution System or a Plant Automation System. All monitoring data is available via digital RS485 communication port running Modbus® Protocol.

    The quality of the power system is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the Acuvim-L power analysis option, any phase current or voltage can be displayed and the harmonic content calculated. By knowing the harmonic distribution, action can be taken to prevent overheated transformers, motors, capacitors, neutral wires and nuisance breaker trips. Redistribution of the system loading can also be determined.


    Those looking for Time of Use (TOU) features should look at the Acuvim-EL instead.


    Key Features

    Metering

    • Voltage V1, V2, V3, V12, V23, V31
    • Current I1, I2, I3, In
    • Power P1, P2, P3, Psum
    • Reactive Power Q1, Q2, Q3, Qsum
    • Apparent Power S1, S2, S3, Ssum
    • Frequency F
    • Power Factor PF1, PF2, PF3, PF
    • Energy Ep_imp, Ep_exp
    • Reactive Energy Eq_imp, Eq_exp
    • Apparent Energy Es
    • Demand Dmd_I1, Dmd_I2, Dmd_I3, Dmd_P, Dmd_Q, Dmd_S

    Monitoring

    • Power Quality (functions not included with the Acuvim-KL)
    • Voltage Harmonics 2nd to 15th and THD( Acuvim-DL is from 2nd to 25th)
    • Current Harmonics 2nd to 15th and THD( Acuvim-DL is from 2nd to 25th)
    • Voltage Unbalance Factor U_unbl (all models excluding the Acuvim-KL)
    • Current Unbalance Factor I_unbl (all models excluding the Acuvim-KL)
    • Max/Min Statistics (all models excluding the Acuvim-KL)
    • Meter Running Time and Load Running Time (Acuvim-DL/EL/KL)

    Alarms

    Two (2) parameters may be set within a specified time interval. If indicated parameter is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the alarm DO output. The indicated parameter can be selected from any of the 35 parameters available.

    Communication

    RS485, industry standard Modbus® RTU protocol; (Only on models CL/DL/EL/KL)
    Option the second RS485, Modbus® RTU protocol; or PROFIBUS-DP/V0 (available for the DL/EL Models)
    Protocol. (just for Acuvim-DL/EL)

    Display

    Clear and large character LCD Screen display with white back light; Wide environmental temperature endurance.


    Acuview Software

    As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

    Acuview Software Features

    • Simple setup feature for fast deployment and configuration Accuenergy meters.
    • Remote and real time monitoring of all meter parameters.
    • Dozens of meters can be connected to a single PC.
    • Multiple meters can be displayed and tiled in one window.
    • Real Time Data Logging.
    • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
    • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
    • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

    Applications

    • Metering of distribution feeders, transformers, generators, capacitor banks and motors.
    • Medium and low voltage systems.
    • Commercial, industrial, utility.
    • Power quality analysis.

    Acuvim L Series is DIN Rail Mountable

    Mounting & Display Options

    The Acuvim II Series is available in two mounting options:

    Standard with LCD Display

    The standard model is ANSI C39.1 Standard Compliant with a small size 96x96 outline.

    DIN Rail Mount (Remote LCD Display Optional)

    The DIN Rail compatible units are DIN 43700 Standard Compliant. The Acuvim L series also offers an optional Remote LCD display.


    Acuvim L Series Typical Wiring

    Typical Wiring Setups for the Acuvim L Series

    Specifications

    Metering
    Parameters Acuvim-L Accuracy Acuvim-EL/KL Accuracy Resolution Range
    Voltage 0.5% 0.5% 0.1 V 20 V to 1000 kV
    Current 0.5% 0.5% 0.001 A 0 to 50000 A
    Current Demand 0.5% 0.5% 0.001 A 0 to 50000 A
    Power 1.0% 0.5% 1 W -9999 to 9999 MW
    Reactive Power 2.0% 0.5% 1 var -9999 to 9999 Mvar
    Apparent Power 1.0% 0.5% 0.001 V 0 to 9999 MVA
    Power Demand 1.0% 0.5% 1 W -9999 to 9999 MW
    Reactive Power Demand 2.0% 0.5% 1 var -9999 to 9999 Mvar
    Apparent Power Demand 1.0% 1 VA 1 VA 0 to 9999 MVA
    Power Factor 1.0% 0.5% 0.001 -1.0 to 1.0
    Frequency 0.2% 0.2% 0.01 Hz 45.00 to 65.00 Hz
    Energy 0.5% 0.5% 0.1 kWh 0 to 99999999.9 kWh
    Reactive Energy 2.0% 0.5% 0.1 kvarh 0 to 99999999.9 kvarh
    Apparent Energy 1.0% 0.5% 0.1 VAh 0 to 99999999.9 kVAh
    Harmonics 2.0% - 0.01% 0 to 100.0%
    Running Time 0.1 hrs 0 to 999999999.9 hrs
    Communication
    RS-485 (Option)
    Modbus-RTU Protocol
    2-wire connection, Half-duplex, Isolated
    1200 to 38400 baud rate
    Input
    Current Inputs (Each Channel)
    Nominal Current 5 A ac
    Metering Range 0 to 6 A ac
    Withstand 20 Arms continuous 100 Arms for 1 second, non-recurring
    Burden 0.05 VA (typical) @ 5 Arms
    Pickup Current 10 Vac
    Accuracy 0.5%
    Voltage Inputs (Each Channel)
    Nominal Full Scale 400 Vac L-N, 690 Vac L-L (+20%)
    Withstand 1500 Vac continuous 2500 Vac, 50/60 Hz for 1 minute
    Input Impedance 45 to 65 Hz
    Pickup Voltage 10 Vac
    Accuracy 0.5%
    Energy Accuracy (Acuvim-EL)
    Active (according to IEC 62053-22) Class 0.5s (according to ANSI C12.20) Class 0.5
    Reactive (according to IEC 62053-23) Class 2
    Harmonic Resolution
    Metered Value 2nd to 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
    Control Power
    Universal AC or DC
    AC/DC Control Power
    Operating Range 100 to 415 Vac, 50/60 Hz, 100 to 300 Vdc
    Burden 3 W
    Withstand 3250 Vac, 50/60 Hz for 1 minute
    Low Voltage DC Control Power (Optional)
    Operating Range 20 to 60 Vdx
    Burden 3 W
    Digital Output Option
    Digital Output (DO) (Photo-MOS)
    Voltage Range 0 to 250 Vac/dc
    Load Current 100 mA (Max)
    Output Frequency 25 Hz, 50% Duty Ratio
    Isolation Voltage 2500 V
    Digital Input Option
    Digital Output (DI)
    Input Voltage Range 20 to 250 Vac/dc
    Input Current (Max) 2 mA
    Start Voltage 15 V
    Stop Voltage 5 V
    Pulse Frequency (Max) 100 Hz, 50% Duty Ratio
    SOE Resolution 2 ms
    Operating Environment
    Operation Temperature -13 to 158°F (-25 to 70°C)
    Storage Temperature -40 to 185°F (-40 to 85°C)
    Relative Humidity 5 to 95% non-condensing
    Pollution Degree 2
    Standard Compliance
    Product
    USA UL 61010-1
    Canada cUL 61010-1
    Europe IEC 61010-1
    Emission
    Radiated/Conducted FCC Part 15 Subpart B, Class A
    Radiated/Conducted EN 55011
    Harmonic IEC 61000-3-2
    Voltage Fluctuation IEC 50081-2
    Radio Interference IEC 50081-2
    Immunity
    ESD IEC 61000-4-2
    Radiated, Radio-frequency, Electromagnetic Field IEC 61000-4-3
    Electrical Fast Transient/Bust IEC 61000-4-4
    Surge IEC 61000-4-5
    Conducted Disturbances IEC 61000-4-6
    Power Frequency Magnetic Field IEC 61000-4-8
    Voltage Dips and Interruptions IEC 61000-4-11
    Generic Immunity Standard for Industrial Environment EN 50082-2
    Click here for complete specifications on the Accuenergy Acuvim-KL-KIT

    What's included with the Accuenergy Acuvim-KL-KIT

  • Three Phase Industrial Device/Panel Power Metering Kit
  • Acuvim II Series Comparison

    Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
    Real Time Metering Phase Voltage U1, U2, U3
    Real Time Metering Line Voltage U12, U23, U31
    Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
    Real Time Metering Power P1, P2, P3, Psum
    Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
    Real Time Metering Apparent Power S1, S2, S3, Ssum
    Real Time Metering Power Factor PF1, PF2, PF3, PF
    Real Time Metering Load Nature L/C/R
    Real Time Metering Frequency F Hz
    Energy & Demand Energy Ep_imp, Ep_exp
    Energy & Demand Reactive Energy Eq_imp, Eq_exp
    Energy & Demand Apparent Energy Es
    Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
    Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
    Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
    Power Quality Voltage Unbalance U_unbl
    Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
    Power Quality Voltage THD THD_V1, THD_V2, THD_V3
    Power Quality Current THD THD_I1, THD_I2, THD_I3
    Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
    Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
    Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
    Statistics Max & Min of Voltage
    Statistics Max & Min of Current
    Hour Running Time Hour
    Hour Load Running Time Hour
    I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
    I/O Alarm Output
    Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
    Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
    Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
    Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

    Acuview Software

    As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

    Acuview Software Features

    • Simple setup feature for fast deployment and configuration Accuenergy meters.
    • Remote and real time monitoring of all meter parameters.
    • Dozens of meters can be connected to a single PC.
    • Multiple meters can be displayed and tiled in one window.
    • Real Time Data Logging.
    • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
    • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
    • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

    Ask a question about Three Phase Industrial Device/Panel Power Metering Kit

    Customer Reviews for the Accuenergy Acuvim-KL-KIT

    More Accuenergy Products

    Calibration Lab