Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Model: T3RC3000-LF

Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Model: T3RC3000-LF

This Rogowski probe has low-frequency performance and a flexible coil. Because it's so flexible, you can use it without modification to the circuit under test.

This Rogowski probe has low-frequency performance and a flexible coil. Because it's so flexible, you can use it without modification to the circuit under test.

Your Price $2020.00 USD
Availability 10 to 11 Weeks
Quantity

Teledyne LeCroy T3RC3000-LF Offers



Get the bandwidth and performance you need when you use the Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe. Between the flexible coil and the low insertion load, it helps testing flow smoothly. You can plug into the wall to work at the bench, or insert the batteries and use it out in the field.

Features

  • Compatible with most oscilloscopes with a BNC input connector and a 1 MΩ input impedance
  • Wide operating temperature ideal for a variety of applications
  • Extended low-frequency performance
  • High level of peak insulation
  • Flexible coil helps increase accuracy while remaining isolated
  • Doesn't require modifications to the DUT
  • Low insertion load of the circuit under test
  • Use with either batteries or the plug-in power adapter
  • Calibrated to ±0.2% reading with conductor central in the coil loop
  • Applications Component Design and Development, System-Level Development, Power Converter Design and Development, Long-Term System Monitoring

Teledyne LeCroy T3RC3000-LF Specifications


Peak Current3,000 A
Bandwidth0.11 Hz to 6.5 MHz
Sensitivity2 mV/A
Max Noise2.5 mV rms
Droop0.1%/ms
LF (-3 dB) Bandwidth0.11 Hz
HF (-3 dB) Bandwidth6.5 MHz
Peak di/dt11 kA/us
Attenuation Ratio500
Cable Length13' (4 m)
Coil Circumference11.8" (300 mm)
Coil Thickness0.33" (8.5 mm)
Peak Coil Insulation Voltage10 kV
Accuracy±1% (variation with conductor position in the coil), 0.05% of reading (linearity of current magnitude)
TemperatureCoil and cable: -4 to 212°F (-20 to 100°C); integrator: 32 to 104°F (0 to 40°C)
Manufacturer Warranty1-year limited
Click here for complete specifications on the Teledyne LeCroy T3RC3000-LF

What's included with the Teledyne LeCroy T3RC3000-LF

  • Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Ask a question about Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Customer Reviews for the Teledyne LeCroy T3RC3000-LF

Teledyne LeCroy T3RC3000-LF Offers



Get the bandwidth and performance you need when you use the Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe. Between the flexible coil and the low insertion load, it helps testing flow smoothly. You can plug into the wall to work at the bench, or insert the batteries and use it out in the field.

Features

  • Compatible with most oscilloscopes with a BNC input connector and a 1 MΩ input impedance
  • Wide operating temperature ideal for a variety of applications
  • Extended low-frequency performance
  • High level of peak insulation
  • Flexible coil helps increase accuracy while remaining isolated
  • Doesn't require modifications to the DUT
  • Low insertion load of the circuit under test
  • Use with either batteries or the plug-in power adapter
  • Calibrated to ±0.2% reading with conductor central in the coil loop
  • Applications Component Design and Development, System-Level Development, Power Converter Design and Development, Long-Term System Monitoring

Teledyne LeCroy T3RC3000-LF Specifications


Peak Current3,000 A
Bandwidth0.11 Hz to 6.5 MHz
Sensitivity2 mV/A
Max Noise2.5 mV rms
Droop0.1%/ms
LF (-3 dB) Bandwidth0.11 Hz
HF (-3 dB) Bandwidth6.5 MHz
Peak di/dt11 kA/us
Attenuation Ratio500
Cable Length13' (4 m)
Coil Circumference11.8" (300 mm)
Coil Thickness0.33" (8.5 mm)
Peak Coil Insulation Voltage10 kV
Accuracy±1% (variation with conductor position in the coil), 0.05% of reading (linearity of current magnitude)
TemperatureCoil and cable: -4 to 212°F (-20 to 100°C); integrator: 32 to 104°F (0 to 40°C)
Manufacturer Warranty1-year limited
Click here for complete specifications on the Teledyne LeCroy T3RC3000-LF

What's included with the Teledyne LeCroy T3RC3000-LF

  • Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Ask a question about Teledyne LeCroy T3RC3000-LF Rogowski AC Current Probe, 3,000 A, 0.11 Hz to 6.5 MHz

Customer Reviews for the Teledyne LeCroy T3RC3000-LF

More Teledyne LeCroy Products

Calibration Lab