The PM-RMV-000C0 is ideal for AC loads found in applications such as electrical motors, which will only operate properly if the AC line voltage and frequency are within the motor's specified tolerances. If the thresholds specified by the motor manufacturer are exceeded, permanent damage to the motor as well as plant equipment could occur. Drops in line voltage or frequency may indicate an excessive load and the possibility of equipment malfunction. This panel meter allows a simple way to monitor AC power lines and provide an alarm of non-compliance.
Features
| Input Signal Ranges (Jumper Selectable) | 200.00 mV, 2.0000 V, 20.000 V, 200.00 V, 300.0 V, 600.0 V |
| Display Range | 0 to 99999 |
| Scaling Function | 5 digits with decimal point adjustment |
| Accuracy @ 77°F (25°C) | ±0.1% of FS ±2 Counts; 5 A Range ±10 mA; 300 V & 600 V = ±0.8 V |
| AC Range (True RMS Volts/Amps) | 0.1% to 100% of Full Scale, 10 Hz to 10 kHz, crest factor 3.0 |
| Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V ac or 24 V dc; SSR: 120 mA @ 140 V ac or 180 V dc |
| Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
| Communication (Optional) | RS-232, RS-485, USB |
| Power Requirement | 85-264 V ac / 95-300 V dc; Optional 10-48 V dc / 12-34 V ac |
| Input Signal Ranges (Jumper Selectable) | 200.00 mV, 2.0000 V, 20.000 V, 200.00 V, 300.0 V, 600.0 V |
| Display Range | 0 to 99999 |
| Scaling Function | 5 digits with decimal point adjustment |
| Accuracy @ 77°F (25°C) | ±0.1% of FS ±2 Counts; 5 A Range ±10 mA; 300 V & 600 V = ±0.8 V |
| AC Range (True RMS Volts/Amps) | 0.1% to 100% of Full Scale, 10 Hz to 10 kHz, crest factor 3.0 |
| Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V ac or 24 V dc; SSR: 120 mA @ 140 V ac or 180 V dc |
| Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
| Communication (Optional) | RS-232, RS-485, USB |
| Power Requirement | 85-264 V ac / 95-300 V dc; Optional 10-48 V dc / 12-34 V ac |