This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. The PM-DCA-000C1 has RS-232 communications.
This panel meter can be set to one of 4 input ranges from ±2.0000 mA with 0.1 µA resolution to ±5.000 A with 1 mA resolution. The PM-DCA-000C1 has RS-232 communications.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Current Panel Meters category for similar products.
Or let's do a search and help you find what you need:
The PM-RMA-000C1 is ideal for AC loads found in applications such as electrical motors, which will only operate properly if the AC line voltage and frequency are within the motor's specified tolerances. If the thresholds specified by the motor manufacturer are exceeded, permanent damage to the motor as well as plant equipment could occur. Drops in line voltage or frequency may indicate an excessive load and the possibility of equipment malfunction. This panel meter allows a simple way to monitor AC power lines and provide an alarm of non-compliance.
Features
Applications
| Input Signal Ranges (Jumper Selectable) | 2.0000 mA, 20.000 mA, 200.00 mA, 5.000 A |
| Display Range | 0 to 99999 |
| Scaling Function | 5 digits with decimal point adjustment |
| Accuracy @ 77°F (25°C) | ±0.1% of FS ±2 Counts; 5 A Range ±10 mA; 300 V & 600 V = ±0.8 V |
| AC Range (True RMS Volts/Amps) | 0.1% to 100% of Full Scale, 10 Hz to 10 kHz, crest factor 3.0 |
| Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V ac or 24 V dc; SSR: 120 mA @ 140 V ac or 180 V dc |
| Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
| Communication (Optional) | RS-232, RS-485, USB |
| Power Requirement | 85-264 V ac / 95-300 V dc; Optional 10-48 V dc / 12-34 V ac |
| Input Signal Ranges (Jumper Selectable) | 2.0000 mA, 20.000 mA, 200.00 mA, 5.000 A |
| Display Range | 0 to 99999 |
| Scaling Function | 5 digits with decimal point adjustment |
| Accuracy @ 77°F (25°C) | ±0.1% of FS ±2 Counts; 5 A Range ±10 mA; 300 V & 600 V = ±0.8 V |
| AC Range (True RMS Volts/Amps) | 0.1% to 100% of Full Scale, 10 Hz to 10 kHz, crest factor 3.0 |
| Display Update Time | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Relay Output (Optional) | Mechanical Relays: 8 A @ 250 V ac or 24 V dc; SSR: 120 mA @ 140 V ac or 180 V dc |
| Analog Signal Output (Optional) | Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V |
| Communication (Optional) | RS-232, RS-485, USB |
| Power Requirement | 85-264 V ac / 95-300 V dc; Optional 10-48 V dc / 12-34 V ac |