This panel meter can be set to one of 6 input ranges from ±200.00 mV with 10 µV resolution to ±600.0 V with 0.1 V resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCV-0R0C0 has a relay output of two 8A form C contact relays.

This panel meter can be set to one of 6 input ranges from ±200.00 mV with 10 µV resolution to ±600.0 V with 0.1 V resolution. It comes standard with an isolated excitation output to power transducers, removing the need for an additional power supply. The PM-DCV-0R0C0 has a relay output of two 8A form C contact relays.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Voltage Panel Meters category for similar products.

Or let's do a search and help you find what you need:


SHIMPO PM-DCV-0R0C0 Offers

The PM-DCV-0R0C0 is ideal for indicating current or voltage signals in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and many more. Used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.

Features

  • Bright, red 5 digit LED display scalable to ±99,999 with adjustable decimal point
  • Universal power range of 85-264 V ac / 90-300 V dc or 10-48 V dc / 12-32 V ac power eliminates need to purchase country specific models
  • Programmable scaling provides flexibility to set up and monitor virtually any process in the desired engineering units
  • Variety of output and communication options:
    • Choice of 2 relays or 2 solid state relays
    • Analog signal option provides: 4-20 mA, 0-20 mA, 0-10 V or -10 V to +10 V outputs
    • Serial data communication of either USB, RS485 or RS232
  • Accuracy of ±0.01% of full scale ±2 counts (LSD)
  • Isolated transducer power output of 5, 10 or 24 V dc, eliminates need for an additional power supply reducing installation costs
  • Digital filtering is menu-selectable for electrically noisy environments
  • Peak and valley values are automatically captured and may be displayed via a pushbutton, control signal input, or be transmitted as serial data if a communication option was ordered
  • High read rates at up to 60 or 50 conversions per second
  • When panel mounted, NEMA 4X (IP65) front cover protection keeps fluids out; enables installation in environments exposed to wash-downs

Applications

  • Detect DC power output
  • Process automation
  • Control
  • Peak or valley capture
  • On/off setpoint alarm

SHIMPO PM-DCV-0R0C0 Specifications

Input Signal Ranges (Jumper Selectable) ±200.00 mV, ±2.0000 V, ±20.000 V, ±200.00 V, ±300.0 V, ±600.0 V
Display Range -99999 to 99999
Scaling Function 5 digits with decimal point adjustment
Accuracy @ 77°F (25°C) ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V
Display Update Time 3.5/s at 60 Hz, 3/s at 50 Hz
Relay Output (Optional) Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc
Analog Signal Output (Optional) Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V
Communication: (Optional) RS-232, RS-485, USB
Power Requirement 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC
Sensor Excitation (Isolated) 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA
Click here for complete specifications on the SHIMPO PM-DCV-0R0C0

What's included with the SHIMPO PM-DCV-0R0C0

  • SHIMPO PM-DCV-0R0C0 Panel Meter, DC Volt Input, Relay Output

Ask a question about SHIMPO PM-DCV-0R0C0 Panel Meter, DC Volt Input, Relay Output

Customer Reviews for the SHIMPO PM-DCV-0R0C0

SHIMPO PM-DCV-0R0C0 Offers

The PM-DCV-0R0C0 is ideal for indicating current or voltage signals in applications involving temperature, pressure, level, flow rate, speed, humidity, level, distance and many more. Used to detect DC power output from solar cells, power supplies, batteries as well as current consumption of DC powered motors and similar devices.

Features

  • Bright, red 5 digit LED display scalable to ±99,999 with adjustable decimal point
  • Universal power range of 85-264 V ac / 90-300 V dc or 10-48 V dc / 12-32 V ac power eliminates need to purchase country specific models
  • Programmable scaling provides flexibility to set up and monitor virtually any process in the desired engineering units
  • Variety of output and communication options:
    • Choice of 2 relays or 2 solid state relays
    • Analog signal option provides: 4-20 mA, 0-20 mA, 0-10 V or -10 V to +10 V outputs
    • Serial data communication of either USB, RS485 or RS232
  • Accuracy of ±0.01% of full scale ±2 counts (LSD)
  • Isolated transducer power output of 5, 10 or 24 V dc, eliminates need for an additional power supply reducing installation costs
  • Digital filtering is menu-selectable for electrically noisy environments
  • Peak and valley values are automatically captured and may be displayed via a pushbutton, control signal input, or be transmitted as serial data if a communication option was ordered
  • High read rates at up to 60 or 50 conversions per second
  • When panel mounted, NEMA 4X (IP65) front cover protection keeps fluids out; enables installation in environments exposed to wash-downs

Applications

  • Detect DC power output
  • Process automation
  • Control
  • Peak or valley capture
  • On/off setpoint alarm

SHIMPO PM-DCV-0R0C0 Specifications

Input Signal Ranges (Jumper Selectable) ±200.00 mV, ±2.0000 V, ±20.000 V, ±200.00 V, ±300.0 V, ±600.0 V
Display Range -99999 to 99999
Scaling Function 5 digits with decimal point adjustment
Accuracy @ 77°F (25°C) ±0.01% of FS ±2 Counts; 5A Range ±10 mA; 300 V & 600 V = ±0.4 V
Display Update Time 3.5/s at 60 Hz, 3/s at 50 Hz
Relay Output (Optional) Mechanical Relays: 8 A @ 250 V AC or 24 V dc; SSR: 120 mA @ 140 V AC or 180 V dc
Analog Signal Output (Optional) Jumper Selectable: 4-20 mA, 0-20 mA, 0-10 V, -10 V to 10 V
Communication: (Optional) RS-232, RS-485, USB
Power Requirement 85-264 V AC / 95-300 V DC; Optional 10-48 V DC / 12-34 V AC
Sensor Excitation (Isolated) 5 Vdc ±5%, 100 mA; 10 V DC ±5%, 120 mA; or 24 V DC ±5%, 50 mA