High precision probe for measuring humidity and temperature and also dew/frost point calculations.

High precision probe for measuring humidity and temperature and also dew/frost point calculations.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Rotronic 0210.HC2-SH Offers

When it comes to measuring humidity with the highest accuracy, the HygroClip2 series of probes is in a class of its own. Based on AirChip3000 technology, its unique features are sure to impress. In combination with advances in sensor technology and integration, the HygroClip2 will provide superb precision and state-of-the-art functionality, taking humidity measurement to a whole new level of performance and reliability (< 0.8 %RH / 0.1 K).

Features

  • Relative humidity, temperature measurement and dew point calculation
  • Outstanding accuracy and repeatability
  • Excellent long-term stability
  • Integrated data acquisition and calibration history
  • Auto-diagnostics with error compensation
  • Programmable alarm functions
  • Advanced easy-to-use calibration features
  • 100% field interchangeable

Fast response
By decoupling the Pt100 temperature sensor fromthe probe, thermal response is significantly improved.

Innovative filter technology
The latest in filter technology provides a high level ofprotection and maintains the optimum measurement environment for the Hygromer humidity and Pt100 temperature sensors.

Factory Adjustment
Two different adjustment profiles are available from the factory; this means that measurement accuracy can be matched to the application need. Calibration data is stored within the probe and can be retrieved later for audit purposes.

Probe Output Signal
When connected to a PC the HygroClip2 probes can be rescaled with different ranges to suit the application need. It is also possible to assign the internally calculated dew or frost point value to one of these outputs; thus converting the HygroClip2 into a dew point probe.

Sensor Diagnostics
The intelligence of AirChip 3000 technology enables advanced sensor diagnostics. Should the RH sensor deviate from factory defined parameters(for example because of chemical contamination) measurement values can be automatically compensated and a digital alarm triggered. The HygroClip2 probe can also be programmed to generate an alarm in the form of pre-defined analog output signals in the event of a problem with either the RH or temperature sensor.The user has full control over these features using ROTRONIC HW4 software.

Data Logging and Alarm Generation
Up to 2,000 measurement values can be stored in the HygroClip2 probe; the user is able to configure the measurement interval, set alarm limits, scale the output signal and download data using optional ROTRONIC HW4 software. The HygroClip2 probe can be programmed with set limits to generate an alarm which is available when the probe is communicating with a PC or compatible ROTRONIC device.Thus,the HygroClip2 can be integrated in any application.

Applications

  • HVAC/R
  • Food Industry
  • Building Services and Equipment
  • Paper
  • Textile
  • Pharmaceutical Industry

Rotronic 0210.HC2-SH Specifications

Operating Range 0 to 100 %rh / -50 to 100°C
Accuracy at 23 ±5°C ±0.5 %rh / ±0.1 K
Power Consumption 3.2 to 5 vdc, Calibration @ 3.3 vdc / ~4.5 mA
Long-term stability <1 %rh / year)
Humidity Sensor Hygromer IN-1
Temperature Sensor PT100 1/3 DIN Class B
Probe Protection Polycarbonate plastic cage, black
Response Time T 63 <15 sec.
Allowed Wind Speed 20 m/s, with filter
Psychrometric Calculations Dew or frost point
Click here for complete specifications on the Rotronic 0210.HC2-SH

What's included with the Rotronic 0210.HC2-SH

  • Rotronic HC2-SH Standard Climate Probe, High Accuracy

Rotronic HC2-SH Standard Climate Probe: Overview


This video will provide the viewers with an overview of this standard climate probe's main features. This tool measures relative humidity, temperature, and dew point. Additionally, it features outstanding accuracy and repeatability.

Click on a category to view a selection of compatible accessories with the Rotronic HC2-SH Standard Climate Probe, High Accuracy.

Rotronic AC3001 USB Cable, UART to USB adapter cable 5220.AC3001
This cable connects HC2 standards and industrial probes to PC using HW4 software.




Ask a question about Rotronic HC2-SH Standard Climate Probe, High Accuracy

Customer Reviews for the Rotronic 0210.HC2-SH

Rotronic 0210.HC2-SH Offers

When it comes to measuring humidity with the highest accuracy, the HygroClip2 series of probes is in a class of its own. Based on AirChip3000 technology, its unique features are sure to impress. In combination with advances in sensor technology and integration, the HygroClip2 will provide superb precision and state-of-the-art functionality, taking humidity measurement to a whole new level of performance and reliability (< 0.8 %RH / 0.1 K).

Features

  • Relative humidity, temperature measurement and dew point calculation
  • Outstanding accuracy and repeatability
  • Excellent long-term stability
  • Integrated data acquisition and calibration history
  • Auto-diagnostics with error compensation
  • Programmable alarm functions
  • Advanced easy-to-use calibration features
  • 100% field interchangeable

Fast response
By decoupling the Pt100 temperature sensor fromthe probe, thermal response is significantly improved.

Innovative filter technology
The latest in filter technology provides a high level ofprotection and maintains the optimum measurement environment for the Hygromer humidity and Pt100 temperature sensors.

Factory Adjustment
Two different adjustment profiles are available from the factory; this means that measurement accuracy can be matched to the application need. Calibration data is stored within the probe and can be retrieved later for audit purposes.

Probe Output Signal
When connected to a PC the HygroClip2 probes can be rescaled with different ranges to suit the application need. It is also possible to assign the internally calculated dew or frost point value to one of these outputs; thus converting the HygroClip2 into a dew point probe.

Sensor Diagnostics
The intelligence of AirChip 3000 technology enables advanced sensor diagnostics. Should the RH sensor deviate from factory defined parameters(for example because of chemical contamination) measurement values can be automatically compensated and a digital alarm triggered. The HygroClip2 probe can also be programmed to generate an alarm in the form of pre-defined analog output signals in the event of a problem with either the RH or temperature sensor.The user has full control over these features using ROTRONIC HW4 software.

Data Logging and Alarm Generation
Up to 2,000 measurement values can be stored in the HygroClip2 probe; the user is able to configure the measurement interval, set alarm limits, scale the output signal and download data using optional ROTRONIC HW4 software. The HygroClip2 probe can be programmed with set limits to generate an alarm which is available when the probe is communicating with a PC or compatible ROTRONIC device.Thus,the HygroClip2 can be integrated in any application.

Applications

  • HVAC/R
  • Food Industry
  • Building Services and Equipment
  • Paper
  • Textile
  • Pharmaceutical Industry

Rotronic 0210.HC2-SH Specifications

Operating Range 0 to 100 %rh / -50 to 100°C
Accuracy at 23 ±5°C ±0.5 %rh / ±0.1 K
Power Consumption 3.2 to 5 vdc, Calibration @ 3.3 vdc / ~4.5 mA
Long-term stability <1 %rh / year)
Humidity Sensor Hygromer IN-1
Temperature Sensor PT100 1/3 DIN Class B
Probe Protection Polycarbonate plastic cage, black
Response Time T 63 <15 sec.
Allowed Wind Speed 20 m/s, with filter
Psychrometric Calculations Dew or frost point
Click here for complete specifications on the Rotronic 0210.HC2-SH

What's included with the Rotronic 0210.HC2-SH

  • Rotronic HC2-SH Standard Climate Probe, High Accuracy

Rotronic HC2-SH Standard Climate Probe: Overview


This video will provide the viewers with an overview of this standard climate probe's main features. This tool measures relative humidity, temperature, and dew point. Additionally, it features outstanding accuracy and repeatability.

Click on a category to view a selection of compatible accessories with the Rotronic HC2-SH Standard Climate Probe, High Accuracy.

Rotronic AC3001 USB Cable, UART to USB adapter cable 5220.AC3001
This cable connects HC2 standards and industrial probes to PC using HW4 software.




Ask a question about Rotronic HC2-SH Standard Climate Probe, High Accuracy

Customer Reviews for the Rotronic 0210.HC2-SH

More Rotronic Products