RKI EAGLE 2 Portable Multi-Gas Detector, LEL and PPM/0 to 2000 ppm PID VOC/O2/H2S

Model: 724-101-P2

RKI EAGLE 2 Portable Multi-Gas Detector, LEL and PPM/0 to 2000 ppm PID VOC/O2/H2S

Model: 724-101-P2

Powerful and portable, this multi-gas detector provides LEL and PPM, O2, H2S, and 0 to 2000 ppm (PID) of VOC detection at the push of a button. In addition, this ergonomic detector features data logging and a powerful internal pump with a low-flow auto shut-off and alarm, which can draw samples from up to 125' (38.1 m).

Powerful and portable, this multi-gas detector provides LEL and PPM, O2, H2S, and 0 to 2000 ppm (PID) of VOC detection at the push of a button. In addition, this ergonomic detector features data logging and a powerful internal pump with a low-flow auto shut-off and alarm, which can draw samples from up to 125' (38.1 m).

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Portable Multi-Gas Detectors category for similar products.

Or let's do a search and help you find what you need:


RKI 724-101-P2 Offers



Equipped with a strong, internal low-flow pump, the RKI 724-101-P2 EAGLE 2 Gas Detector is capable of drawing samples from up to 125' (38.1 m). The pump boasts auto shut-off and an alarm for simple operation, and the detector is designed for detection of VOCs, O₂ and H₂S. The data logging feature allows you to review the measurements later.

Features

  • Provides accurate detection at the push of a button
  • PID sensor detects high and low ppm of VOC gases in ranges from 0 to 50 and 0 to 2,000
  • Methane elimination is available for environmental applications
  • Data logging capability allows you to review the results later
  • Requires a standard IrDA/USB cable (47-5027RK) to download the data
  • Alkaline battery power provides up to 18 hours of continuous operation
  • Factory calibration of LEL/ppm ranges is to methane; factory calibration of PID sensor is to isobutylene

RKI 724-101-P2 Specifications

Oxygen (O2) Measuring range: 0 to 40% Vol
Accuracy: ± 0.5% O2
Hydrogen Sulfide (H2S) Measuring range: 0 to 100 ppm
Accuracy: ± 5% of reading or ± 2 ppm H2S (Which ever is greater)
VOC Measuring range: 0 to 2000 ppm
Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, infrared, photoionization detector, and thermal conductivity
Sampling Method Powerful, long-life internal pump (over 6000 hours) can draw samples over 125' (38.1 m). Flow rate approximately 2.0 SCFH
Response Time 30 seconds to 90% (for most gases) using standard 5' (1.52 m) hose
Controls 4 external glove friendly push buttons for operation, demand zero, and auto calibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features
Alarms 2 alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable
Method: Buzzer 95 dB at 11.81" (30 cm), four high intensity LED’s
Safety Rating Intrinsically safe, Class I, Groups A, B, C, D. Approvals: CSA/CE
Environmental IP-64
Enclosure Weatherproof, chemical resistant, RFI/EMI coated high impact polycarbonate-PBT blend. Can operate in 2" (5.08 cm) of water without leakage. Ergonomically balanced with rugged top mounted handle. Water and dust resistant equivalent to IP64.
Operating Temperature and Humidity -4 to 122°F (-20 to 50°C), 0 to 95% RH, non-condensing
Language Readout can display in 5 languages (English, French, German, Italian, or Spanish)
Display 3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand, with adjustable time
Power Source: 4 alkaline or NiMH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines)
Continuous operation: At 70°F (21.11°C), 18 hours using alkaline batteries, or 20 hours using NiMH
Dimensions 9.5 x 5.25 x 5.875" (24.13 x 13.33 x 14.92 cm)
Weight 3.8 lbs (1.72 g), standard 4 gas with batteries
Click here for complete specifications on the RKI 724-101-P2

What's included with the RKI 724-101-P2


  • Gas Detector
  • 13-0100RK Shoulder Strap with RKI Logo for EAGLE/EAGLE 2
  • 33-0173RK Internal Hydrophobic Filter for EAGLE 2
  • 49-1130RK C Alkaline Battery
  • 71-8003RK EAGLE 2 Product CD
  • 80-0131RK-20 10" (254 mm) Standard Hydrophobic Probe with metal fittings for EAGLE 2 with PID
  • 80-0605RK 5' (1.52 m) Teflon-Lined Hose with Fittings

Ask a question about RKI EAGLE 2 Portable Multi-Gas Detector, LEL and PPM/0 to 2000 ppm PID VOC/O2/H2S

Customer Reviews for the RKI 724-101-P2

RKI 724-101-P2 Offers



Equipped with a strong, internal low-flow pump, the RKI 724-101-P2 EAGLE 2 Gas Detector is capable of drawing samples from up to 125' (38.1 m). The pump boasts auto shut-off and an alarm for simple operation, and the detector is designed for detection of VOCs, O₂ and H₂S. The data logging feature allows you to review the measurements later.

Features

  • Provides accurate detection at the push of a button
  • PID sensor detects high and low ppm of VOC gases in ranges from 0 to 50 and 0 to 2,000
  • Methane elimination is available for environmental applications
  • Data logging capability allows you to review the results later
  • Requires a standard IrDA/USB cable (47-5027RK) to download the data
  • Alkaline battery power provides up to 18 hours of continuous operation
  • Factory calibration of LEL/ppm ranges is to methane; factory calibration of PID sensor is to isobutylene

RKI 724-101-P2 Specifications

Oxygen (O2) Measuring range: 0 to 40% Vol
Accuracy: ± 0.5% O2
Hydrogen Sulfide (H2S) Measuring range: 0 to 100 ppm
Accuracy: ± 5% of reading or ± 2 ppm H2S (Which ever is greater)
VOC Measuring range: 0 to 2000 ppm
Detection Principle Catalytic combustion, electrochemical cell, galvanic cell, infrared, photoionization detector, and thermal conductivity
Sampling Method Powerful, long-life internal pump (over 6000 hours) can draw samples over 125' (38.1 m). Flow rate approximately 2.0 SCFH
Response Time 30 seconds to 90% (for most gases) using standard 5' (1.52 m) hose
Controls 4 external glove friendly push buttons for operation, demand zero, and auto calibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features
Alarms 2 alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable
Method: Buzzer 95 dB at 11.81" (30 cm), four high intensity LED’s
Safety Rating Intrinsically safe, Class I, Groups A, B, C, D. Approvals: CSA/CE
Environmental IP-64
Enclosure Weatherproof, chemical resistant, RFI/EMI coated high impact polycarbonate-PBT blend. Can operate in 2" (5.08 cm) of water without leakage. Ergonomically balanced with rugged top mounted handle. Water and dust resistant equivalent to IP64.
Operating Temperature and Humidity -4 to 122°F (-20 to 50°C), 0 to 95% RH, non-condensing
Language Readout can display in 5 languages (English, French, German, Italian, or Spanish)
Display 3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand, with adjustable time
Power Source: 4 alkaline or NiMH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines)
Continuous operation: At 70°F (21.11°C), 18 hours using alkaline batteries, or 20 hours using NiMH
Dimensions 9.5 x 5.25 x 5.875" (24.13 x 13.33 x 14.92 cm)
Weight 3.8 lbs (1.72 g), standard 4 gas with batteries
Click here for complete specifications on the RKI 724-101-P2

What's included with the RKI 724-101-P2


  • Gas Detector
  • 13-0100RK Shoulder Strap with RKI Logo for EAGLE/EAGLE 2
  • 33-0173RK Internal Hydrophobic Filter for EAGLE 2
  • 49-1130RK C Alkaline Battery
  • 71-8003RK EAGLE 2 Product CD
  • 80-0131RK-20 10" (254 mm) Standard Hydrophobic Probe with metal fittings for EAGLE 2 with PID
  • 80-0605RK 5' (1.52 m) Teflon-Lined Hose with Fittings

Ask a question about RKI EAGLE 2 Portable Multi-Gas Detector, LEL and PPM/0 to 2000 ppm PID VOC/O2/H2S

Customer Reviews for the RKI 724-101-P2

More RKI Products

Calibration Lab