RKI 722-106-P12 EAGLE 2 Sensor, VOCs 0 to 2,000 ppm (PID)/VOCs 0 to 50 ppm (PID)

Model: 722-106-P12

RKI 722-106-P12 EAGLE 2 Sensor, VOCs 0 to 2,000 ppm (PID)/VOCs 0 to 50 ppm (PID)

Model: 722-106-P12

The sensor is designed to ppm or LEL hydrocarbon detection. It's capable of methane elimination and features a strong internal pump.

The sensor is designed to ppm or LEL hydrocarbon detection. It's capable of methane elimination and features a strong internal pump.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

RKI GX-6000 PID Multi-Gas Detector-

RKI GX-6000 PID Multi-Gas Detector

Model: 72-6XAB-C

In addition to simultaneously monitoring the standard 4 confined space gases (LEL, O2, CO, and H2S), the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. It features a rugged design for harsh environments, a removable impact-resistant rubber boot, a dust/water-resistant enclosure with an IP67 rating, a Li-ion battery pack, and a 115 V AC charger.


Not what you're looking for? Let’s do a search and help you find what you need.


RKI 722-106-P12 Offers



The RKI 722-106-P12 EAGLE 2 Sensor offers ppm or LEL hydrocarbon detection at the push of a button. It has a strong internal pump with a low flow auto pump shut off and alarm, allowing for quick response and recovery from distant sampling locations. The sensor continuously operates for over 18 hours on alkaline batteries or for up to 20 hours on a Ni-MH battery.

Features

  • LEL or ppm hydrocarbon detection at the push of a button
  • Capable of methane elimination if calibrated to hexane
  • Standard factory calibration of LEL/ppm ranges is to Methane
  • Standard factory calibration of PID sensors is to Isobutylene
  • Some super toxic gas versions have longer lead times than others
  • Strong internal pump with a low flow auto pump shut off and alarm, allowing for quick response and recovery from distant sampling locations
  • Continuously operates for over 18 hours on alkaline batteries or 20 hours on Ni-MH
  • Infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges
  • PID sensor for detecting high and low ppm levels of VOC gases; methane elimination feature for environmental applications

RKI 722-106-P12 Specifications


Sample DistanceUp to 125' (38.1 m)
PPM Levels0 to 50 and 0 to 2,000
Click here for complete specifications on the RKI 722-106-P12

What's included with the RKI 722-106-P12


  • EAGLE 2 Sensor
  • Internal Hydrophobic Filter for EAGLE 2
  • C-Size Alkaline Battery
  • Product CD
  • Standard Hydrophobic Probe with Particle Filter and Metal Fittings for EAGLE/EAGLE 2
  • Standard Hydrophobic Probe with Metal Fittings for EAGLE 2 with PID
  • Polyurethane Hose with Fittings for EAGLE/EAGLE 2
  • Teflon Lined Hose with Fittings
  • Shoulder Strap with RKI Logo for EAGLE/EAGLE 2
  • Data Downloading and Maintenance Software
  • Operator's Manual
  • Training Video
  • Spare Parts List

Ask a question about RKI 722-106-P12 EAGLE 2 Sensor, VOCs 0 to 2,000 ppm (PID)/VOCs 0 to 50 ppm (PID)

Customer Reviews for the RKI 722-106-P12

RKI 722-106-P12 Offers



The RKI 722-106-P12 EAGLE 2 Sensor offers ppm or LEL hydrocarbon detection at the push of a button. It has a strong internal pump with a low flow auto pump shut off and alarm, allowing for quick response and recovery from distant sampling locations. The sensor continuously operates for over 18 hours on alkaline batteries or for up to 20 hours on a Ni-MH battery.

Features

  • LEL or ppm hydrocarbon detection at the push of a button
  • Capable of methane elimination if calibrated to hexane
  • Standard factory calibration of LEL/ppm ranges is to Methane
  • Standard factory calibration of PID sensors is to Isobutylene
  • Some super toxic gas versions have longer lead times than others
  • Strong internal pump with a low flow auto pump shut off and alarm, allowing for quick response and recovery from distant sampling locations
  • Continuously operates for over 18 hours on alkaline batteries or 20 hours on Ni-MH
  • Infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges
  • PID sensor for detecting high and low ppm levels of VOC gases; methane elimination feature for environmental applications

RKI 722-106-P12 Specifications


Sample DistanceUp to 125' (38.1 m)
PPM Levels0 to 50 and 0 to 2,000
Click here for complete specifications on the RKI 722-106-P12

What's included with the RKI 722-106-P12


  • EAGLE 2 Sensor
  • Internal Hydrophobic Filter for EAGLE 2
  • C-Size Alkaline Battery
  • Product CD
  • Standard Hydrophobic Probe with Particle Filter and Metal Fittings for EAGLE/EAGLE 2
  • Standard Hydrophobic Probe with Metal Fittings for EAGLE 2 with PID
  • Polyurethane Hose with Fittings for EAGLE/EAGLE 2
  • Teflon Lined Hose with Fittings
  • Shoulder Strap with RKI Logo for EAGLE/EAGLE 2
  • Data Downloading and Maintenance Software
  • Operator's Manual
  • Training Video
  • Spare Parts List

Ask a question about RKI 722-106-P12 EAGLE 2 Sensor, VOCs 0 to 2,000 ppm (PID)/VOCs 0 to 50 ppm (PID)

Customer Reviews for the RKI 722-106-P12

More RKI Products

Calibration Lab