RKI EAGLE Portable Multi-Gas Detector, LEL and PPM/HF

Model: 72-5261RK

RKI EAGLE Portable Multi-Gas Detector, LEL and PPM/HF

Model: 72-5261RK

Powerful and versatile, this multi-gas-gas detector provides simultaneous LEL, PPM, and hydrogen fluoride (HF) detection at the push of a button. In addition, this ergonomic detector features a powerful internal pump with a low-flow auto shut-off and alarm, which can draw samples from up to 125' (38.1 m).

Powerful and versatile, this multi-gas-gas detector provides simultaneous LEL, PPM, and hydrogen fluoride (HF) detection at the push of a button. In addition, this ergonomic detector features a powerful internal pump with a low-flow auto shut-off and alarm, which can draw samples from up to 125' (38.1 m).

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Portable Multi-Gas Detectors category for similar products.

Or let's do a search and help you find what you need:


RKI 72-5261RK Offers

Equipped with features that are not available on most competitive units, the EAGLE is a powerful instrument that does more than just offer the standard confined space protection for LEL, O₂, H₂S and CO.  Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors.

Unique EAGLE features include PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO₂, methane or hydrocarbons in LEL and % volume ranges; a methane elimination switch for environmental applications, a long list of super toxic gases and measurable ranges, and dual hydrophobic filters that increases its water resistant performance. The EAGLE has a strong internal pump with a low flow auto shut off and alarm, which can draw samples from up to 125 feet even with the dual hydrophobic filters in place. This allows for quick response and recovery from distant sampling locations. The EAGLE will continuously operate for over 30 hours on alkaline batteries or 18 hours on Ni-Cads. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, data logging, continuous operation adapters, remote alarms and strobes, and dilution fittings, just to name a few. 

With its ergonomic design and large glove friendly buttons, the EAGLE offers easy access to controls such as auto-calibration, alarm silence, demand zero, peak hold and a wide variety of other features. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting. Rugged, reliable, easy to operate and maintain, the EAGLE is the solution for just about any portable gas monitoring situation.

Features:

  • Simultaneous detection of up to 6 different gases
  • Over 400 gas monitoring configurations
  • Wide range of toxic gases
  • PPM/LEL hydrocarbon detection
  • Powerful long-life pump up to 125’ range with filters
  • Low flow pump shut off and alarm
  • Methane elimination switch for environmental use
  • Security “Adjustment Lockout Switch”
  • Up to 30 hours of continuous operation
  • Alkaline or Ni-Cad capability
  • IR sensors available for CO₂, % LEL CH₄ or HC, % Volume CH₄ or HC
  • Transformer testing version available
  • Data logging option
  • Auto calibration/Single gas calibration
  • Dual hydrophobic filters (most versions)
  • Ergonomic RFI/EMI/chemical/weather resistant enclosure
  • Intrinsically safe design, CSA (C/US) & UL classified (most versions)
  • Complies with EPA Method 21

Standard Accessories Include:

  • Shoulder strap
  • Alkaline batteries
  • Hydrophobic probe
  • 5’ hose
  • Internal hydrophobic filter (most versions)(certain toxic versions equipped with special probe)
  • Inlet fitting
  • 3’ Teflon hose (note: for HF and O₃ versions, 3’ PTFE hose used without probe)

Important Notes to Customer:

  • Data logging cannot be added to a 5 or 6 gas EAGLE, or an EAGLE with more than 2 toxic sensors.  ANY sensor that is not an Oxygen or LEL (Catalytic) sensor is counted as a toxic sensor.
  • Data logging cannot be added to an EAGLE which has the extra loud buzzer added to EAGLE part no. 52-1017RK-01
  • The Methane Elimination Switch is not operable for instruments calibrated to Methane.
  • The High Capacity Hydrophobic/Dust AcroPac filter (part no. 33-0171RK-01) can only be used in an EAGLE with LEL/O₂/H₂S/CO and no super-toxics, or an EAGLE that has super-toxic sensors but no sensors for LEL/O₂/H₂S/CO.
  • All EAGLEs configured with a Carbon Dioxide channel have a part number suffix (-XX), which indicates one of 5 available Carbon Dioxide ranges that are available for you to choose at checkout.  Some EAGLE configurations do not support the 0-20% and 0-60% CO₂ ranges.  Consult Wilmington Instrument Co. or RKI Instruments, Inc. for specific configurations not supporting these ranges.
  • Standard factory calibration of LEL/PPM ranges is to Methane (calibration to hexane, isobutene, or other gases is optional).  For units provided with an external Methane elimination switch, calibration is to hexane.
  • Some SUPER TOXIC gas versions have longer lead times than others.  Please confirm availability of the SUPER TOXIC versions, or any versions, if delivery time is critical.

Some SUPER TOXIC gas versions have longer lead times than others.

Probes and Hoses for Super Toxic EAGLES

Note that due to absorption issues some versions with super toxic sensors (Br2, ClO2, F2, HCl, HF and O3) have different hose fittings than the standard 4 gas units.  These versions also are supplied with only 3’ of Teflon Tubing as standard, and some versions (F2, HF, and O3) cannot be used with a probe due to absorption, so they will come without a probe.


What's included with the RKI 72-5261RK

  • RKI EAGLE Portable Multi-Gas Detector, LEL and PPM/HF

Ask a question about RKI EAGLE Portable Multi-Gas Detector, LEL and PPM/HF

Customer Reviews for the RKI 72-5261RK

RKI 72-5261RK Offers

Equipped with features that are not available on most competitive units, the EAGLE is a powerful instrument that does more than just offer the standard confined space protection for LEL, O₂, H₂S and CO.  Detection combinations never before offered in a portable gas monitor are now available featuring the industry’s widest selection of high quality, long life and field proven sensors.

Unique EAGLE features include PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO₂, methane or hydrocarbons in LEL and % volume ranges; a methane elimination switch for environmental applications, a long list of super toxic gases and measurable ranges, and dual hydrophobic filters that increases its water resistant performance. The EAGLE has a strong internal pump with a low flow auto shut off and alarm, which can draw samples from up to 125 feet even with the dual hydrophobic filters in place. This allows for quick response and recovery from distant sampling locations. The EAGLE will continuously operate for over 30 hours on alkaline batteries or 18 hours on Ni-Cads. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, data logging, continuous operation adapters, remote alarms and strobes, and dilution fittings, just to name a few. 

With its ergonomic design and large glove friendly buttons, the EAGLE offers easy access to controls such as auto-calibration, alarm silence, demand zero, peak hold and a wide variety of other features. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting. Rugged, reliable, easy to operate and maintain, the EAGLE is the solution for just about any portable gas monitoring situation.

Features:

  • Simultaneous detection of up to 6 different gases
  • Over 400 gas monitoring configurations
  • Wide range of toxic gases
  • PPM/LEL hydrocarbon detection
  • Powerful long-life pump up to 125’ range with filters
  • Low flow pump shut off and alarm
  • Methane elimination switch for environmental use
  • Security “Adjustment Lockout Switch”
  • Up to 30 hours of continuous operation
  • Alkaline or Ni-Cad capability
  • IR sensors available for CO₂, % LEL CH₄ or HC, % Volume CH₄ or HC
  • Transformer testing version available
  • Data logging option
  • Auto calibration/Single gas calibration
  • Dual hydrophobic filters (most versions)
  • Ergonomic RFI/EMI/chemical/weather resistant enclosure
  • Intrinsically safe design, CSA (C/US) & UL classified (most versions)
  • Complies with EPA Method 21

Standard Accessories Include:

  • Shoulder strap
  • Alkaline batteries
  • Hydrophobic probe
  • 5’ hose
  • Internal hydrophobic filter (most versions)(certain toxic versions equipped with special probe)
  • Inlet fitting
  • 3’ Teflon hose (note: for HF and O₃ versions, 3’ PTFE hose used without probe)

Important Notes to Customer:

  • Data logging cannot be added to a 5 or 6 gas EAGLE, or an EAGLE with more than 2 toxic sensors.  ANY sensor that is not an Oxygen or LEL (Catalytic) sensor is counted as a toxic sensor.
  • Data logging cannot be added to an EAGLE which has the extra loud buzzer added to EAGLE part no. 52-1017RK-01
  • The Methane Elimination Switch is not operable for instruments calibrated to Methane.
  • The High Capacity Hydrophobic/Dust AcroPac filter (part no. 33-0171RK-01) can only be used in an EAGLE with LEL/O₂/H₂S/CO and no super-toxics, or an EAGLE that has super-toxic sensors but no sensors for LEL/O₂/H₂S/CO.
  • All EAGLEs configured with a Carbon Dioxide channel have a part number suffix (-XX), which indicates one of 5 available Carbon Dioxide ranges that are available for you to choose at checkout.  Some EAGLE configurations do not support the 0-20% and 0-60% CO₂ ranges.  Consult Wilmington Instrument Co. or RKI Instruments, Inc. for specific configurations not supporting these ranges.
  • Standard factory calibration of LEL/PPM ranges is to Methane (calibration to hexane, isobutene, or other gases is optional).  For units provided with an external Methane elimination switch, calibration is to hexane.
  • Some SUPER TOXIC gas versions have longer lead times than others.  Please confirm availability of the SUPER TOXIC versions, or any versions, if delivery time is critical.

Some SUPER TOXIC gas versions have longer lead times than others.

Probes and Hoses for Super Toxic EAGLES

Note that due to absorption issues some versions with super toxic sensors (Br2, ClO2, F2, HCl, HF and O3) have different hose fittings than the standard 4 gas units.  These versions also are supplied with only 3’ of Teflon Tubing as standard, and some versions (F2, HF, and O3) cannot be used with a probe due to absorption, so they will come without a probe.


What's included with the RKI 72-5261RK

  • RKI EAGLE Portable Multi-Gas Detector, LEL and PPM/HF

Ask a question about RKI EAGLE Portable Multi-Gas Detector, LEL and PPM/HF

Customer Reviews for the RKI 72-5261RK

More RKI Products

Calibration Lab