RKC THV-1PZ-030-5*HN Single Phase Power Controller with heater break alarm, 30 A AC, 0 to 10 V DC

Model: THV-1PZ-030-5*HN | Order No: THV-1PZ-030-5-*HN

RKC THV-1PZ-030-5*HN Single Phase Power Controller with heater break alarm, 30 A AC, 0 to 10 V DC

Model: THV-1PZ-030-5*HN | Order No: THV-1PZ-030-5-*HN

Loaded with numerous functions, this compact power controller has a maximum load capacity of 30 A AC and an input signal of 0 to 10 V DC. In addition, it includes functions such as a heater break alarm and a space-saving design with excellent response and reproducibility.

Loaded with numerous functions, this compact power controller has a maximum load capacity of 30 A AC and an input signal of 0 to 10 V DC. In addition, it includes functions such as a heater break alarm and a space-saving design with excellent response and reproducibility.

Your Price $241.00 USD
Availability 2 to 3 Weeks
Quantity

RKC THV-1PZ-030-5*HN Offers

Single phase power controller has an LED display to show set values and input signals and front keys for easy setting and monitoring. Loaded with versatile standard functions, this power controller operates at 100 up to 240 V AC and automatically selects power supply frequency 50 or 60 Hz.

Features

  • Maximum load capacity: 30 A AC
  • Supply voltage: 100 to 240 V AC
  • Control method: Phase control
  • Easy setup using keypad and front display
  • Conforming to UL and CE Marking

Applications

  • Cascade temperature control in diffusion furnace
  • Highly accurate temperature control of T-die

RKC THV-1PZ-030-5*HN Specifications

Load Current Maximum: 30 A AC
Minimum: 1 A
Control Method Phase control
Applicable Load Linearity (R:Resistor) load
Inductive load (When phase control: Control of primary side of a transformer, magnetic field density 1.25T or less)
Input Signal Current input 4 to 20 mA DC (Input impedance: 100 Ω)
Voltage input 1 to 5V DC (Input impedance: 30 kΩ)
Voltage pulse input 0/12 V DC (Input impedance: 30 kΩ)
Non-voltage contact input (Input impedance: 47 Ω)
Output Voltage Range 0 to 98% of rated voltage
Power Supply voltage: 90 to 264 V AC (Including power supply voltage variation) [Rating: 100 to 240 V DC]
Frequency: 50/60 Hz (Automatic discriminating)
Allowable Power frequency variation: ±1 Hz (Performance guarantee range); ±2 Hz (Operating guarantee range)
Ambient temperature: Performance guarantee: 0 to 40°C; Operating guarantee range: 5 to 131°F (-15 to 55°C)
Ambient humidity: 5 to 95%RH (Non-condensing)
Output Setting range Gradient setting: 0.0 to 100% (Front key or external setting unit)
Output limiter (High): 0.0 to 99.9% (Front key or external setting unit)
Output limiter (Low): 0.0 to 99.9% (Front key or external setting unit)
Base-up setting (Output bias): 0.0 to 99.9% (Front key)
Manual setting: 0.0 to 99.9% (Front key)
Output Mode When phase control is selected for linearity load (R: resistor), output mode can be selected from Proportional phase angle to input, proportional voltage to input, and proportional square voltage (electric power) to input
Heater Break Alarm Accuracy: Less than ±2 A
Alarm decision delay frequency: 0 to 99
Output: Open collector output, 24 V DC, maximum 100 mA
Cooling Method Natural convection
Dielectric Voltage Between main circuit, power terminals and radiation fins: 2000 V AC for one minute
Insulation Resistance Between main circuit, power terminals and radiation fins: 20 M ohms or more (500 V DC)
Mounting Method Vertical
Contents of Digital Display Input signal value
Phase angle ratio value
Frequency value
Control method
Soft up/Soft down time
Gradient set value
Output limiter (High/Low)
Base-up set value
Compliance with Standards UL Recognized
Weight Approximately 1.98 lbs (0.9 kg)
Click here for complete specifications on the RKC THV-1PZ-030-5*HN

What's included with the RKC THV-1PZ-030-5*HN

  • Single Phase Power Controller
  • Heat Breaker Alarm

Ask a question about RKC THV-1PZ-030-5*HN Single Phase Power Controller with heater break alarm, 30 A AC, 0 to 10 V DC

Customer Reviews for the RKC THV-1PZ-030-5*HN

RKC THV-1PZ-030-5*HN Offers

Single phase power controller has an LED display to show set values and input signals and front keys for easy setting and monitoring. Loaded with versatile standard functions, this power controller operates at 100 up to 240 V AC and automatically selects power supply frequency 50 or 60 Hz.

Features

  • Maximum load capacity: 30 A AC
  • Supply voltage: 100 to 240 V AC
  • Control method: Phase control
  • Easy setup using keypad and front display
  • Conforming to UL and CE Marking

Applications

  • Cascade temperature control in diffusion furnace
  • Highly accurate temperature control of T-die

RKC THV-1PZ-030-5*HN Specifications

Load Current Maximum: 30 A AC
Minimum: 1 A
Control Method Phase control
Applicable Load Linearity (R:Resistor) load
Inductive load (When phase control: Control of primary side of a transformer, magnetic field density 1.25T or less)
Input Signal Current input 4 to 20 mA DC (Input impedance: 100 Ω)
Voltage input 1 to 5V DC (Input impedance: 30 kΩ)
Voltage pulse input 0/12 V DC (Input impedance: 30 kΩ)
Non-voltage contact input (Input impedance: 47 Ω)
Output Voltage Range 0 to 98% of rated voltage
Power Supply voltage: 90 to 264 V AC (Including power supply voltage variation) [Rating: 100 to 240 V DC]
Frequency: 50/60 Hz (Automatic discriminating)
Allowable Power frequency variation: ±1 Hz (Performance guarantee range); ±2 Hz (Operating guarantee range)
Ambient temperature: Performance guarantee: 0 to 40°C; Operating guarantee range: 5 to 131°F (-15 to 55°C)
Ambient humidity: 5 to 95%RH (Non-condensing)
Output Setting range Gradient setting: 0.0 to 100% (Front key or external setting unit)
Output limiter (High): 0.0 to 99.9% (Front key or external setting unit)
Output limiter (Low): 0.0 to 99.9% (Front key or external setting unit)
Base-up setting (Output bias): 0.0 to 99.9% (Front key)
Manual setting: 0.0 to 99.9% (Front key)
Output Mode When phase control is selected for linearity load (R: resistor), output mode can be selected from Proportional phase angle to input, proportional voltage to input, and proportional square voltage (electric power) to input
Heater Break Alarm Accuracy: Less than ±2 A
Alarm decision delay frequency: 0 to 99
Output: Open collector output, 24 V DC, maximum 100 mA
Cooling Method Natural convection
Dielectric Voltage Between main circuit, power terminals and radiation fins: 2000 V AC for one minute
Insulation Resistance Between main circuit, power terminals and radiation fins: 20 M ohms or more (500 V DC)
Mounting Method Vertical
Contents of Digital Display Input signal value
Phase angle ratio value
Frequency value
Control method
Soft up/Soft down time
Gradient set value
Output limiter (High/Low)
Base-up set value
Compliance with Standards UL Recognized
Weight Approximately 1.98 lbs (0.9 kg)
Click here for complete specifications on the RKC THV-1PZ-030-5*HN

What's included with the RKC THV-1PZ-030-5*HN

  • Single Phase Power Controller
  • Heat Breaker Alarm

Ask a question about RKC THV-1PZ-030-5*HN Single Phase Power Controller with heater break alarm, 30 A AC, 0 to 10 V DC

Customer Reviews for the RKC THV-1PZ-030-5*HN

More RKC Products

Calibration Lab