Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Model: RAYCI1A50LW

Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Model: RAYCI1A50LW

The CI sensor provides the advantages of infrared temperature measurement in a compact, low cost sensor and can easily replace traditional contact probes with a J-type or K-type thermocouple output, or with a 0-5V output, when integrated into a standard 4-wire system.

The CI sensor provides the advantages of infrared temperature measurement in a compact, low cost sensor and can easily replace traditional contact probes with a J-type or K-type thermocouple output, or with a 0-5V output, when integrated into a standard 4-wire system.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Sensors category for similar products.

Or let's do a search and help you find what you need:


Raytek RAYCI1A50LW Offers

Designed for easy integration into a standard 4-wire system, the CI1A sensor can easily replace traditional contact probes with a J-type thermocouple output. Because the CI unit has the same 50Ω output impedance as a thermocouple, it functions accurately — without offset errors— when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.

Designed to measure target temperatures ranging from 0 to 115°C (32 to 240°F), the CI unit's onboard electronics are protected by a rugged IP 65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 70°C (160°F) without cooling. With water cooling, the CI sensor can withstand ambient temperatures to 260°C (500°F). Optional cooling jacket must be specified at the time of order.

Can be used in the following applications: blow moulding, bonding, coating, converting, curing, drying, embossing, extrusion, forming, heating, laminating, moulding, ovens, paint drying, paving, printing, and thermo-forming.

Raytek RAYCI1A50LW Specifications

Temperature Range 0 to 115ºC (32 to 240ºF)
Temperature Resolution <0.5°C or 1°F
Accuracy ±2% or ±3ºC (6°F), whichever is greater
System Repeatability ±1% of measured value or ±1°C (2°F), whichever is greater
Response Time (95%) 350 mSec
Emissivity Fixed at 0.95
Spectral Response 7 to 18 µm
Optical Resolution 4:1 (Distance : Spot Size)

 

Click here for complete specifications on the Raytek RAYCI1A50LW

What's included with the Raytek RAYCI1A50LW

  • Infrared sensor
  • Water cooled jacket
  • Two mounting nuts
  • 15m (50 ft.) of high temperature cable
  • Operator’s manual

Ask a question about Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Customer Reviews for the Raytek RAYCI1A50LW

Raytek RAYCI1A50LW Offers

Designed for easy integration into a standard 4-wire system, the CI1A sensor can easily replace traditional contact probes with a J-type thermocouple output. Because the CI unit has the same 50Ω output impedance as a thermocouple, it functions accurately — without offset errors— when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.

Designed to measure target temperatures ranging from 0 to 115°C (32 to 240°F), the CI unit's onboard electronics are protected by a rugged IP 65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 70°C (160°F) without cooling. With water cooling, the CI sensor can withstand ambient temperatures to 260°C (500°F). Optional cooling jacket must be specified at the time of order.

Can be used in the following applications: blow moulding, bonding, coating, converting, curing, drying, embossing, extrusion, forming, heating, laminating, moulding, ovens, paint drying, paving, printing, and thermo-forming.

Raytek RAYCI1A50LW Specifications

Temperature Range 0 to 115ºC (32 to 240ºF)
Temperature Resolution <0.5°C or 1°F
Accuracy ±2% or ±3ºC (6°F), whichever is greater
System Repeatability ±1% of measured value or ±1°C (2°F), whichever is greater
Response Time (95%) 350 mSec
Emissivity Fixed at 0.95
Spectral Response 7 to 18 µm
Optical Resolution 4:1 (Distance : Spot Size)

 

Click here for complete specifications on the Raytek RAYCI1A50LW

What's included with the Raytek RAYCI1A50LW

  • Infrared sensor
  • Water cooled jacket
  • Two mounting nuts
  • 15m (50 ft.) of high temperature cable
  • Operator’s manual

Ask a question about Raytek RAYCI1A50LW Infrared Temperature Sensor with Cooling Jacket, 15m Cable, Type J Output, 0 to 115°C (32 to 240°F)

Customer Reviews for the Raytek RAYCI1A50LW

More Raytek Products

Calibration Lab