The Phase II PTG-4000 coating thickness gauge can perform two different methods of calculating thickness measurement by utilizing the characteristics of both eddy current and magnetic induction. With this state of the art gauge, you can easily detect the thickness of nonmagnetic coating on a magnetic substrate (ferrous) or an insulating coating on a non-magnetic conductive substrate (non-ferrous) utilizing our auto-detect, integrated probe.


Phase II PTG-3550 Coating Thickness Gauge with External Probe

Use Phase II PTG-3550 Coating Thickness Gauge with External Probe to easily detect the thickness of nonmagnetic coating on a magnetic substrate.

Simplicity in coating thickness measurement!

The PHASE II PTG-3550 coating thickness gauge can perform two different methods of calculating thickness measurement by utilizing the characteristics of both eddy current and magnetic induction.

Testing performance is both non-destructive and extremely accurate.

With this state of the art thickness gauge, you can easily detect the thickness of nonmagnetic coating on a magnetic substrate (ferrous) or an insulating coating on a non-magnetic conductive substrate (non-ferrous) utilizing either an integrated probe or our version that comes with 1 auto-detect external probe.

The PHASE II PTG-3550 can be used in many areas of industry including manufacturing, general engineering, commercial inspection, etc.

Main Technical Data

  • Measuring range: 0-2000 µ m max. or 0-80 mils
  • Resolution: 0.1µ m / 0.01mils(0-99µ m) or 1µ m (over 100µ m)
  • Guaranteed tolerance:
  • After one-point calibration: +/- 1-3%n or 2µ m (whichever is greater)
  • Display: 4 digits (digit height = 10mm/0.4")
  • Min. measuring area: 0.2" x 0.2" (5mm x 5mm)
  • Min. radius of curvature: Convex: 0.12" (3mm)
  • Concave: 1.2" (30mm)
  • Min. substrate thickness: Ferrous: 20 mils (0.5mm)
  • Non-ferrous: 2 mils (50 µ m)
  • Calibration: Zero Calibration
  • Foil calibration
  • Max. Surface temperature of test object: 302 degrees F (contact time max is 2 seconds)
  • Power source: 4 AA batteries
  • Dimensions: 161 x 69 x 32mm
  • Weight: 9oz. (260g)

What's included with the Phase II PTG-3550

  • Phase II PTG-3550 Coating Thickness Gauge with External Probe

Ask a question about Phase II PTG-3550 Coating Thickness Gauge with External Probe

Customer Reviews for the Phase II PTG-3550

Phase II PTG-3550 Coating Thickness Gauge with External Probe

Use Phase II PTG-3550 Coating Thickness Gauge with External Probe to easily detect the thickness of nonmagnetic coating on a magnetic substrate.

Simplicity in coating thickness measurement!

The PHASE II PTG-3550 coating thickness gauge can perform two different methods of calculating thickness measurement by utilizing the characteristics of both eddy current and magnetic induction.

Testing performance is both non-destructive and extremely accurate.

With this state of the art thickness gauge, you can easily detect the thickness of nonmagnetic coating on a magnetic substrate (ferrous) or an insulating coating on a non-magnetic conductive substrate (non-ferrous) utilizing either an integrated probe or our version that comes with 1 auto-detect external probe.

The PHASE II PTG-3550 can be used in many areas of industry including manufacturing, general engineering, commercial inspection, etc.

Main Technical Data

  • Measuring range: 0-2000 µ m max. or 0-80 mils
  • Resolution: 0.1µ m / 0.01mils(0-99µ m) or 1µ m (over 100µ m)
  • Guaranteed tolerance:
  • After one-point calibration: +/- 1-3%n or 2µ m (whichever is greater)
  • Display: 4 digits (digit height = 10mm/0.4")
  • Min. measuring area: 0.2" x 0.2" (5mm x 5mm)
  • Min. radius of curvature: Convex: 0.12" (3mm)
  • Concave: 1.2" (30mm)
  • Min. substrate thickness: Ferrous: 20 mils (0.5mm)
  • Non-ferrous: 2 mils (50 µ m)
  • Calibration: Zero Calibration
  • Foil calibration
  • Max. Surface temperature of test object: 302 degrees F (contact time max is 2 seconds)
  • Power source: 4 AA batteries
  • Dimensions: 161 x 69 x 32mm
  • Weight: 9oz. (260g)

What's included with the Phase II PTG-3550

  • Phase II PTG-3550 Coating Thickness Gauge with External Probe

Ask a question about Phase II PTG-3550 Coating Thickness Gauge with External Probe