Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded

Model: TT-T-24S-SLE-500

Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded

Model: TT-T-24S-SLE-500

Made for thermocouple circuits, this duplex Type T thermocouple wire uses PFA insulation rated for use up to 392°F (200°C). It has stranded 24 AWG conductors with ANSI color coding, built to special limits of error, and ships on a 500' (150 m) spool. Moreover, it is used for fabricating thermocouples and wiring sensors to controllers, meters, and data loggers.

Made for thermocouple circuits, this duplex Type T thermocouple wire uses PFA insulation rated for use up to 392°F (200°C). It has stranded 24 AWG conductors with ANSI color coding, built to special limits of error, and ships on a 500' (150 m) spool. Moreover, it is used for fabricating thermocouples and wiring sensors to controllers, meters, and data loggers.

Your Price $581.06 USD
Availability 2 to 3 Weeks
Quantity

OMEGA TT-T-24S-SLE-500 Offers

Applications

  • Fabricating and wiring thermocouple sensors
  • Connecting thermocouples to temperature controllers and meters
  • Routing thermocouple signals to data loggers and recorders
  • Industrial process and equipment temperature monitoring
  • Laboratory and test-bench temperature measurement

OMEGA TT-T-24S-SLE-500 Specifications

Thermocouple type Type T
Conductors Copper-Constantan
Standards ANSI (IEC color code available)
Limits of error Special limits of error
Construction Duplex insulated
Conductor Stranded (7 x 32)
Wire gauge 24 AWG
Insulation PFA (Neoflon)
Maximum temperature 400°F (200°C)
Positive wire color Blue
Negative wire color Red
Overall color Brown
Spool length 500' (150 m)
Dimensions 0.063 x 0.102" (1.6 x 2.6 mm)
Weight Spool and wire weight: 7 lbs/1000' (3 kg/300 m)

What's included with the OMEGA TT-T-24S-SLE-500

  • Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded

Click on a category to view a selection of compatible accessories with the Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded.

Omega SMP-T-M Miniature Thermocouple Connector, type T male, glass-filled nylon SMP-T-M
Rated for use over -20 to 356°F (-29 to 180°C), this Type T male miniature thermocouple connector has a glass-filled nylon body. It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Additionally, it is suited to connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-M Standard Thermocouple Connector, type T male, glass-filled nylon OST-T-M
Built with a glass-filled nylon body, this Type T male standard thermocouple connector is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. It is commonly used for connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-F Standard Thermocouple Connector, type T female, glass-filled nylon OST-T-F
Made for field and panel wiring, this Type T female standard thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Omega SMP-T-F Miniature Thermocouple Connector, type T female, glass-filled nylon SMP-T-F
Made for field and panel wiring, this Type T female miniature thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Ask a question about Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded

Customer Reviews for the OMEGA TT-T-24S-SLE-500

OMEGA TT-T-24S-SLE-500 Offers

Applications

  • Fabricating and wiring thermocouple sensors
  • Connecting thermocouples to temperature controllers and meters
  • Routing thermocouple signals to data loggers and recorders
  • Industrial process and equipment temperature monitoring
  • Laboratory and test-bench temperature measurement

OMEGA TT-T-24S-SLE-500 Specifications

Thermocouple type Type T
Conductors Copper-Constantan
Standards ANSI (IEC color code available)
Limits of error Special limits of error
Construction Duplex insulated
Conductor Stranded (7 x 32)
Wire gauge 24 AWG
Insulation PFA (Neoflon)
Maximum temperature 400°F (200°C)
Positive wire color Blue
Negative wire color Red
Overall color Brown
Spool length 500' (150 m)
Dimensions 0.063 x 0.102" (1.6 x 2.6 mm)
Weight Spool and wire weight: 7 lbs/1000' (3 kg/300 m)

What's included with the OMEGA TT-T-24S-SLE-500

  • Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded

Click on a category to view a selection of compatible accessories with the Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded.

Omega SMP-T-M Miniature Thermocouple Connector, type T male, glass-filled nylon SMP-T-M
Rated for use over -20 to 356°F (-29 to 180°C), this Type T male miniature thermocouple connector has a glass-filled nylon body. It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Additionally, it is suited to connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-M Standard Thermocouple Connector, type T male, glass-filled nylon OST-T-M
Built with a glass-filled nylon body, this Type T male standard thermocouple connector is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. It is commonly used for connecting thermocouple wire and probes to extension wire and instruments.




Omega OST-T-F Standard Thermocouple Connector, type T female, glass-filled nylon OST-T-F
Made for field and panel wiring, this Type T female standard thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Omega SMP-T-F Miniature Thermocouple Connector, type T female, glass-filled nylon SMP-T-F
Made for field and panel wiring, this Type T female miniature thermocouple connector has a glass-filled nylon body rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Ask a question about Omega TT-T-24S-SLE-500 Type T Thermocouple Wire, PFA insulation, 24 AWG, special limits of error, 500' spool, stranded

Customer Reviews for the OMEGA TT-T-24S-SLE-500

More OMEGA Products