Built for on/off media control, this solenoid valve is a 2-way, normally-open, direct-acting valve with a 1/4" port and a 0.63 Cv flow coefficient. Its brass body with FKM seals handles up to 45 psi (3.1 bar) on AC or 15 psi (1 bar) on DC and operates to 280°F (137°C). With an AC or DC coil, it works great for liquid and gas service.
Built for on/off media control, this solenoid valve is a 2-way, normally-open, direct-acting valve with a 1/4" port and a 0.63 Cv flow coefficient. Its brass body with FKM seals handles up to 45 psi (3.1 bar) on AC or 15 psi (1 bar) on DC and operates to 280°F (137°C). With an AC or DC coil, it works great for liquid and gas service.
SV-3300 Series 2-way solenoid valves are direct-acting valves featuring brass, stainless steel construction and FKM seal material. The temperature range from 14 to 280°F (-10 to 137°C) is ideal for neutral media such as compressed air, inert gases, water, and synthetic oils.
Features
Applications
| Mounting position | Any (preferably with solenoid system upright) |
| Maximum process temperature | 280°F (137°C) due to FKM O-ring |
| Maximum ambient temperature | Coil dependent (see ratings on coils) |
| Voltage tolerance | ±10% |
| Opening time | AC: 10 to 20 msec DC: 20 to 80 msec depending on orifice and pressure |
| Closing time | AC and DC: 20 to 30 msec approximately |
| Cycling rate | Approx. 1000 cpm |
| Duty cycle | Continuous (100%) |
| Body | Brass |
| Armature tube | Stainless Steel 300 |
| Fixed core | Stainless Steel 400 |
| Plunger | Stainless Steel 400 |
| Spring | Stainless Steel 300 |
| Shading ring | Copper |
| Orifice less than or equal to 1/8" | Stainless Steel 300 |
| Orifice greater than 1/8" | Brass |
| Sealing material | FKM |
| Coil VA (8 W) | Inrush 25, holding 14 |
| Coil VA (12 W) | Inrush 36, holding 23 |
| Coil VA (14 W) | Inrush 43, holding 27 |
| Pipe size | 1/4" |
| Orifice size | 7/32" |
| Cv flow factor | 0.63 |
| Standard coil | 8 W |
| Optional coil | 12 or 14 W |
| Minimum operating pressure | 0 psi |
| Maximum operational pressure differential, AC, 8 W | 45 psi |
| Maximum operational pressure differential, AC, 12 W/14 W | 100/145 psi |
| Maximum operational pressure differential, DC, 8 W | 15 psi |
| Maximum operational pressure differential, DC, 12 W/14 W | 35/70 psi |
| Valve function | Normally Open |
| Dimensions | A: 1-3/32" B: 3-1/16" C: 1-5/8" 8 W coil D: 1-3/16", E: 1-21/32", F: 2-1/8" 12 W coil D: 1-7/16", E: 1-29/32", F: 2-3/8" 14 W coil D: 2-1/16", E: 2-5/32", F: 2-5/8" |
| Mounting position | Any (preferably with solenoid system upright) |
| Maximum process temperature | 280°F (137°C) due to FKM O-ring |
| Maximum ambient temperature | Coil dependent (see ratings on coils) |
| Voltage tolerance | ±10% |
| Opening time | AC: 10 to 20 msec DC: 20 to 80 msec depending on orifice and pressure |
| Closing time | AC and DC: 20 to 30 msec approximately |
| Cycling rate | Approx. 1000 cpm |
| Duty cycle | Continuous (100%) |
| Body | Brass |
| Armature tube | Stainless Steel 300 |
| Fixed core | Stainless Steel 400 |
| Plunger | Stainless Steel 400 |
| Spring | Stainless Steel 300 |
| Shading ring | Copper |
| Orifice less than or equal to 1/8" | Stainless Steel 300 |
| Orifice greater than 1/8" | Brass |
| Sealing material | FKM |
| Coil VA (8 W) | Inrush 25, holding 14 |
| Coil VA (12 W) | Inrush 36, holding 23 |
| Coil VA (14 W) | Inrush 43, holding 27 |
| Pipe size | 1/4" |
| Orifice size | 7/32" |
| Cv flow factor | 0.63 |
| Standard coil | 8 W |
| Optional coil | 12 or 14 W |
| Minimum operating pressure | 0 psi |
| Maximum operational pressure differential, AC, 8 W | 45 psi |
| Maximum operational pressure differential, AC, 12 W/14 W | 100/145 psi |
| Maximum operational pressure differential, DC, 8 W | 15 psi |
| Maximum operational pressure differential, DC, 12 W/14 W | 35/70 psi |
| Valve function | Normally Open |
| Dimensions | A: 1-3/32" B: 3-1/16" C: 1-5/8" 8 W coil D: 1-3/16", E: 1-21/32", F: 2-1/8" 12 W coil D: 1-7/16", E: 1-29/32", F: 2-3/8" 14 W coil D: 2-1/16", E: 2-5/32", F: 2-5/8" |