Used for timing control of machinery and process equipment, this panel-mount digital timer uses a dual 4-digit red LED with five programmable timing modes and time ranges from 99.99 sec to 9999 hrs. It provides one changeover and one N/O relay output and is powered from 24 V AC/DC. It has an IP65 enclosure, selectable up/down timing, and EEPROM memory.
Used for timing control of machinery and process equipment, this panel-mount digital timer uses a dual 4-digit red LED with five programmable timing modes and time ranges from 99.99 sec to 9999 hrs. It provides one changeover and one N/O relay output and is powered from 24 V AC/DC. It has an IP65 enclosure, selectable up/down timing, and EEPROM memory.
The Omega PTC-14-A dual 4 digit digital timer is a multifunction, multi-time range digital timer suitable for controlling operation of equipment, machinery, systems or processes in a wide range of industrial applications. Five timing functions can be selected together with time ranges from 0.01 second to 9999 hours, to operate two independent relay output contacts which are isolated from the supply voltage. The output contacts can be configured as two timed outputs, or one timed and one instantaneous output. These timers are housed in a compact panel mounting enclosure and are powered from 24 V AC/dc or 100-240 V AC.
Features
Applications
| Accuracy | ±0.1% of full scale |
| Power supply voltage | 24 V AC/dc |
| Burden | <3 VA |
| Frequency | 50/60 Hz |
| Time ranges | 0.01 to 99.99 sec, 00:01 to 99:59 minimum, 00:01 to 99:59 hrs, 1 to 9999 hrs |
| Relay output | Single pole changeover contact and single pole N/O contact |
| Contact rating | OP1 16 A at 250 V AC/30 V DC (resistive); OP2 5 A at 250 V AC/30 V DC (resistive) |
| Electrical contact life | 100,000 operations |
| Reset time | 100 ms approx. |
| Enclosure | Panel mounting to DIN 43700, self extinguishing plastic case, plug in connection terminals |
| Panel cutout | 71 mm x 29 mm (-0.0/+0.5) |
| Enclosure code | Case IP65 |
| Operating temperature | 32°F to 122°F (0°C to 50°C) |
| Storage temperature | -4°F to 140°F (-20°C to 60°C) |
| Markings | CE marked (meets 2014/35/EU low voltage and 2014/30/EU EMC directives) |
| Weight | Weight: 0.37 lb (170 g) |
| Accuracy | ±0.1% of full scale |
| Power supply voltage | 24 V AC/dc |
| Burden | <3 VA |
| Frequency | 50/60 Hz |
| Time ranges | 0.01 to 99.99 sec, 00:01 to 99:59 minimum, 00:01 to 99:59 hrs, 1 to 9999 hrs |
| Relay output | Single pole changeover contact and single pole N/O contact |
| Contact rating | OP1 16 A at 250 V AC/30 V DC (resistive); OP2 5 A at 250 V AC/30 V DC (resistive) |
| Electrical contact life | 100,000 operations |
| Reset time | 100 ms approx. |
| Enclosure | Panel mounting to DIN 43700, self extinguishing plastic case, plug in connection terminals |
| Panel cutout | 71 mm x 29 mm (-0.0/+0.5) |
| Enclosure code | Case IP65 |
| Operating temperature | 32°F to 122°F (0°C to 50°C) |
| Storage temperature | -4°F to 140°F (-20°C to 60°C) |
| Markings | CE marked (meets 2014/35/EU low voltage and 2014/30/EU EMC directives) |
| Weight | Weight: 0.37 lb (170 g) |