Ideal for water and wastewater treatment, this pH/ORP controller measures -2.00 to 16.00 pH (or -1999 to 1999 mV ORP) with ±0.01 pH accuracy and automatic temperature compensation. It provides three 1 A SPST relays, a 0 to 20 mA/4 to 20 mA isolated output, and RS485 communications behind a blue-backlit 4-digit LCD. The NEMA 4X (IP65) enclosure panel mounts and includes built-in memory backup.
Ideal for water and wastewater treatment, this pH/ORP controller measures -2.00 to 16.00 pH (or -1999 to 1999 mV ORP) with ±0.01 pH accuracy and automatic temperature compensation. It provides three 1 A SPST relays, a 0 to 20 mA/4 to 20 mA isolated output, and RS485 communications behind a blue-backlit 4-digit LCD. The NEMA 4X (IP65) enclosure panel mounts and includes built-in memory backup.
The PHCN-961/962 series of pH controller and transmitter provides a reliable method of monitoring and controlling pH in water treatment, electrolytic water cleaning, chemical industry, food process, cleaning water or wastewater treatment, and neutralization processes.
The controllers standard features include a digital display capable of displaying pH readings between -2 and 16 pH or ORP readings between -2000 an 2000 mV. Additional features include temperature, and status of relays, adjustable dual alarm set points, dead band adjustments of 0.01 to 2 pH of the setpoint, and menu-driven program to set up pH or ORP calibration.
The PHCN-961/962 is a basic pH or ORP controller, it includes a NEMA 4X (IP65) enclosure, digital display, two separate setpoints for high and low alarms, adjust dead bands, three 1 A SSRs. Accepts one pH or ORP electrode input through supplied pH transmitter.
Features
Applications
| pH Range | -2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | -1999 to 1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 14.2 to 266°F (-9.9 to 130°C) |
| Temperature Resolution | 0.1° |
| Temperature Accuracy | ±0.5°C |
| Temperature Sensor | 1000 Ω Pt RTD |
| Temperature Compensation | Automatic with ±10°C offset adjustment or manual |
| Cleaning/Recalibration Notification | Programmable from 1 to 999 hours |
| pH Deadband Adjust | 0.01 to 2 pH |
| ORP Deadband Adjust | 1 to 200 mV |
| Relay Output | Three SPST relays, rated 250 V @ 1 A |
| Analog Output | 0 to 20 mA/4 to 20 mA isolated current output |
| Signal Output Load | 600 Ω |
| pH/ORP Input | BNC connector |
| Input Impedance | 10^13 Ω |
| Communications | RS485 client program |
| Power | 110 or 220 V AC, 50 or 60 Hz |
| Display | 4-digit LCD, 0.54" (13.7 mm); blue backlit |
| Operating Ambient | 14 to 122°F (-10 to 50°C); 10 to 95% RH, non-condensing |
| Mounting | Panel mount |
| Enclosure | NEMA 4X (IP65) |
| Dimensions | 4.25 x 3.93 x 5.82" (10.8 x 10 x 14.8 cm) Panel Cutout: 3.68 in² (93.5 mm²) |
| pH Range | -2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | -1999 to 1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 14.2 to 266°F (-9.9 to 130°C) |
| Temperature Resolution | 0.1° |
| Temperature Accuracy | ±0.5°C |
| Temperature Sensor | 1000 Ω Pt RTD |
| Temperature Compensation | Automatic with ±10°C offset adjustment or manual |
| Cleaning/Recalibration Notification | Programmable from 1 to 999 hours |
| pH Deadband Adjust | 0.01 to 2 pH |
| ORP Deadband Adjust | 1 to 200 mV |
| Relay Output | Three SPST relays, rated 250 V @ 1 A |
| Analog Output | 0 to 20 mA/4 to 20 mA isolated current output |
| Signal Output Load | 600 Ω |
| pH/ORP Input | BNC connector |
| Input Impedance | 10^13 Ω |
| Communications | RS485 client program |
| Power | 110 or 220 V AC, 50 or 60 Hz |
| Display | 4-digit LCD, 0.54" (13.7 mm); blue backlit |
| Operating Ambient | 14 to 122°F (-10 to 50°C); 10 to 95% RH, non-condensing |
| Mounting | Panel mount |
| Enclosure | NEMA 4X (IP65) |
| Dimensions | 4.25 x 3.93 x 5.82" (10.8 x 10 x 14.8 cm) Panel Cutout: 3.68 in² (93.5 mm²) |