Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code

Model: OSTW-E-M

Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code-

Image is for reference only, refer to product info for complete details.

Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code

Model: OSTW-E-M

Built with a glass-filled nylon body, this Type E male standard thermocouple connector is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Moreover, it is used for connecting thermocouple wire and probes to extension wire and instruments.

Built with a glass-filled nylon body, this Type E male standard thermocouple connector is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Moreover, it is used for connecting thermocouple wire and probes to extension wire and instruments.

Your Price $6.98 USD
Availability 2 to 3 Weeks
Quantity

OMEGA OSTW-E-M Offers

Features

  • Universal female fits-all design
  • Hollow-pin construction
  • Color-coding for ANSI or IEC
  • Captive cover screws
  • Accepts stranded or solid wire up to size 14 AWG
  • Quick connect contact washers
  • Internal wire divider
  • Write-on window
  • Combination Phillips/slot screws

Applications

  • Terminating thermocouple wire for quick-disconnect connections
  • Connecting thermocouple probes to extension wire and instruments
  • Industrial process temperature sensor connections
  • Panel and instrument wiring in temperature measurement systems
  • Laboratory and test-setup thermocouple connections

OMEGA OSTW-E-M Specifications

Series OSTW/OST (glass-filled nylon) / HSTW/HST (liquid crystal polymer)
Design Universal female fits-all, hollow pin
Standards ANSI and IEC color codes
Cover screws Captive
Screws Combination Phillips/slot
Internal wire divider Yes
Wire size Stranded or solid up to size 14 AWG
Calibration Type E
Shell color (ANSI) Purple
Compensating alloy CHROMEGA®/Constantan
Connector gender Male
Service temperature -20 to 356°F (-29 to 180°C)
Variant SMPW-size, glass-filled nylon, with write-on window
Dimensions Wire access hole diameter: 0.22" (5.5 mm)

What's included with the OMEGA OSTW-E-M

  • Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code

Click on a category to view a selection of compatible accessories with the Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code.

Omega JP-E-F Standard Thermocouple Panel Jack, type E female JP-E-F
Built with a glass-filled nylon body, this Type E female standard thermocouple panel jack is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Omega RSJ-E-R Standard Round-Hole Thermocouple Panel Jack, type E, round face RSJ-E-R
Round-hole standard thermocouple panel jack for Type E connectors, with a round face bezel and a 1/2-14 NPSL threaded body. It mounts in a drilled or punched round panel hole and is secured with the supplied nut. Moreover, it is used for adding thermocouple circuits to existing instrument panels.




Omega SPJ-E-F Universal Snap-In Thermocouple Panel Jack, type E female SPJ-E-F
Universal snap-in thermocouple panel jack for Type E connectors, glass-filled nylon, rated for use over -20 to 356°F (-29 to 180°C). It snaps into a single rectangular panel cutout and accepts OMEGA and industry-standard miniature connectors. Furthermore, it supports panel-mounting thermocouple connections on instruments and enclosures.




Omega PCLM-FT Ferrite Cable Clamp for standard thermocouple connectors PCLM-FT
Ferrite cable clamp that attaches to standard thermocouple connectors to help reduce EMI/RFI noise in the measurement circuit. It includes a molded-in nickel-zinc ferrite core and accepts duplex wire up to 14 AWG. It is compatible with OST, OSTW, HST, HSTW, OGP, HGST, OTP connectors.




Ask a question about Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code

Customer Reviews for the OMEGA OSTW-E-M

OMEGA OSTW-E-M Offers

Features

  • Universal female fits-all design
  • Hollow-pin construction
  • Color-coding for ANSI or IEC
  • Captive cover screws
  • Accepts stranded or solid wire up to size 14 AWG
  • Quick connect contact washers
  • Internal wire divider
  • Write-on window
  • Combination Phillips/slot screws

Applications

  • Terminating thermocouple wire for quick-disconnect connections
  • Connecting thermocouple probes to extension wire and instruments
  • Industrial process temperature sensor connections
  • Panel and instrument wiring in temperature measurement systems
  • Laboratory and test-setup thermocouple connections

OMEGA OSTW-E-M Specifications

Series OSTW/OST (glass-filled nylon) / HSTW/HST (liquid crystal polymer)
Design Universal female fits-all, hollow pin
Standards ANSI and IEC color codes
Cover screws Captive
Screws Combination Phillips/slot
Internal wire divider Yes
Wire size Stranded or solid up to size 14 AWG
Calibration Type E
Shell color (ANSI) Purple
Compensating alloy CHROMEGA®/Constantan
Connector gender Male
Service temperature -20 to 356°F (-29 to 180°C)
Variant SMPW-size, glass-filled nylon, with write-on window
Dimensions Wire access hole diameter: 0.22" (5.5 mm)

What's included with the OMEGA OSTW-E-M

  • Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code

Click on a category to view a selection of compatible accessories with the Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code.

Omega JP-E-F Standard Thermocouple Panel Jack, type E female JP-E-F
Built with a glass-filled nylon body, this Type E female standard thermocouple panel jack is rated for use over -20 to 356°F (-29 to 180°C). It accepts stranded or solid thermocouple wire and uses ANSI/IEC color coding for fast, correct connections. Common uses include connecting thermocouple wire and probes to extension wire and instruments.




Omega RSJ-E-R Standard Round-Hole Thermocouple Panel Jack, type E, round face RSJ-E-R
Round-hole standard thermocouple panel jack for Type E connectors, with a round face bezel and a 1/2-14 NPSL threaded body. It mounts in a drilled or punched round panel hole and is secured with the supplied nut. Moreover, it is used for adding thermocouple circuits to existing instrument panels.




Omega SPJ-E-F Universal Snap-In Thermocouple Panel Jack, type E female SPJ-E-F
Universal snap-in thermocouple panel jack for Type E connectors, glass-filled nylon, rated for use over -20 to 356°F (-29 to 180°C). It snaps into a single rectangular panel cutout and accepts OMEGA and industry-standard miniature connectors. Furthermore, it supports panel-mounting thermocouple connections on instruments and enclosures.




Omega PCLM-FT Ferrite Cable Clamp for standard thermocouple connectors PCLM-FT
Ferrite cable clamp that attaches to standard thermocouple connectors to help reduce EMI/RFI noise in the measurement circuit. It includes a molded-in nickel-zinc ferrite core and accepts duplex wire up to 14 AWG. It is compatible with OST, OSTW, HST, HSTW, OGP, HGST, OTP connectors.




Ask a question about Omega OSTW-E-M Standard Thermocouple Connector with write-on window, type E male, glass-filled nylon, IEC color code

Customer Reviews for the OMEGA OSTW-E-M

More OMEGA Products