Built for automatic gaging for quality control, this gaging transducer is supplied with -0.2 to 0.2" (5 to 5 mm), ± 0.25 %, 56 mV/V/ mm O/P. It has input current of 10 to 13 mA. It also suits go/no-go inspection.
Built for automatic gaging for quality control, this gaging transducer is supplied with -0.2 to 0.2" (5 to 5 mm), ± 0.25 %, 56 mV/V/ mm O/P. It has input current of 10 to 13 mA. It also suits go/no-go inspection.
These precision-manufactured displacement transducers can be mounted to most production lines to perform automatic gaging for quality, sorting, or go/no-go applications. The hardened steel shaft, O-ring seals, and titanium pushrod can withstand most industrial conditions. The hybrid IC module produces a linear mV/V/mm (or inch) output that will interface with most standard DC input meters, recorders, data interfaces, and industrial controllers.
Features
Applications
| Series | LD500 Series |
| Type | gaging transducer |
| Configuration | -0.2" (5 mm) to 0.2" (5 mm) |
| Accuracy | ± 0.25 % |
| Output type | 56 mV/V/ mm O/P |
| Configuration | Steel |
| Cable | 6.56' (2 m) Cable |
| Configuration | 0.74" (18.8 mm) Diameter |
| Configuration | 1.9" (4.8 cm) Length |
| Input Current | 10 to 13 mA |
| Input Voltage | 10 to 24 V DC |
| Linearity | 0.0025 |
| Ripple (Typical) | <1% FS |
| Time Response | 1.5 ms |
| Frequency | 100 Hz for -3 dB |
| Temperature Coefficient, Zero | <0.01%/°C |
| Temperature Coefficient, Sensitivity | <0.01%/°C |
| Cable | 6.6' (2 m) long, PVC 5-wire shielded |
| Replaceable Tip Thread | 3-56 thread |
| Temperature Range | -4 to 176°F (-20 to 80°C) |
| Sensitivity | 78 mV/V/mm (1.98 mV/V/0.001 inch) for LD500-1 and -2.5; 56 mV/V/mm for LD500-5 |
| Linear Stroke | ±0.04" (1.0 mm) (LD500-1); ±0.10" (2.5 mm) (LD500-2.5); ±0.20" (5.0 mm) (LD500-5); output nulls in mechanical middle |
| Spring Rate | 13 g/mm (LD500-1, -2.5); 10 g/mm (LD500-5) |
| Repeatability | <0.15 mm (6 minimum) (LD500-1, -2.5); <0.10 mm (4 minimum) (LD500-5) |
| Housing Diameter | 8h6 ø (0.315" (8 mm)); body ø0.74" (19 mm) |
| Wiring | RED + Excitation, BLUE – Excitation, WHITE + Signal, GREEN – Signal |
| Construction | Hardened steel shaft, O-ring seals, titanium pushrod, linear ball-bearing actuator; nitrile or FKM gaiter |
| Compatible Meters | DP41-S, DP25B-S |
| Series | LD500 Series |
| Type | gaging transducer |
| Configuration | -0.2" (5 mm) to 0.2" (5 mm) |
| Accuracy | ± 0.25 % |
| Output type | 56 mV/V/ mm O/P |
| Configuration | Steel |
| Cable | 6.56' (2 m) Cable |
| Configuration | 0.74" (18.8 mm) Diameter |
| Configuration | 1.9" (4.8 cm) Length |
| Input Current | 10 to 13 mA |
| Input Voltage | 10 to 24 V DC |
| Linearity | 0.0025 |
| Ripple (Typical) | <1% FS |
| Time Response | 1.5 ms |
| Frequency | 100 Hz for -3 dB |
| Temperature Coefficient, Zero | <0.01%/°C |
| Temperature Coefficient, Sensitivity | <0.01%/°C |
| Cable | 6.6' (2 m) long, PVC 5-wire shielded |
| Replaceable Tip Thread | 3-56 thread |
| Temperature Range | -4 to 176°F (-20 to 80°C) |
| Sensitivity | 78 mV/V/mm (1.98 mV/V/0.001 inch) for LD500-1 and -2.5; 56 mV/V/mm for LD500-5 |
| Linear Stroke | ±0.04" (1.0 mm) (LD500-1); ±0.10" (2.5 mm) (LD500-2.5); ±0.20" (5.0 mm) (LD500-5); output nulls in mechanical middle |
| Spring Rate | 13 g/mm (LD500-1, -2.5); 10 g/mm (LD500-5) |
| Repeatability | <0.15 mm (6 minimum) (LD500-1, -2.5); <0.10 mm (4 minimum) (LD500-5) |
| Housing Diameter | 8h6 ø (0.315" (8 mm)); body ø0.74" (19 mm) |
| Wiring | RED + Excitation, BLUE – Excitation, WHITE + Signal, GREEN – Signal |
| Construction | Hardened steel shaft, O-ring seals, titanium pushrod, linear ball-bearing actuator; nitrile or FKM gaiter |
| Compatible Meters | DP41-S, DP25B-S |