This cantilever beam load cell measures compression up to 100 lbf (445 N). It provides a 3 mV/V output and ±0.03% accuracy. It includes 5-point NIST-traceable calibration and suits industrial force measurement and test stand and bench testing.
This cantilever beam load cell measures compression up to 100 lbf (445 N). It provides a 3 mV/V output and ±0.03% accuracy. It includes 5-point NIST-traceable calibration and suits industrial force measurement and test stand and bench testing.
OMEGA LC501 Series high-accuracy stainless steel cantilever beam load cells provide all stainless steel construction for harsh industrial applications with 0.25% interchangeability. They measure tension or compression and are available in standard and metric models with a 5-point calibration.
Features
Applications
| Series | LC501 Series |
| Type | Cantilever Beam Load Cell |
| Load mode | Compression |
| Rated capacity | 100 lbf (445 N) |
| Excitation | 10 V DC, 15 V DC maximum |
| Rated output | 3 mV/V ±0.25% |
| Linearity | ±0.03% FSO |
| Hysteresis | ±0.05% FSO |
| Repeatability | ±0.02% FSO |
| Zero balance | ±1% FSO |
| Operating temperature range | -30 to 180°F (-34 to 82°C) |
| Compensated temperature range | 60 to 160°F (16 to 71°C) |
| Thermal effect on zero | ±0.001% FSO/°F (0.0018%/°C) |
| Thermal effect on span | ±0.001% FSO/°F (0.0018%/°C) |
| Safe overload | 150% of capacity |
| Ultimate overload | 300% of capacity |
| Input resistance | 360 Ω minimum |
| Output resistance | 350 ±10 Ω |
| Full scale deflection | 0.02" (0.5 mm) typical |
| Construction | 17-4 PH stainless steel |
| Calibration | 5-point NIST traceable certificate included |
| Cable | 15' (4.57 m) cable |
| Electrical connection | Cable (Cable) |
| Interchangeability | 0.25% Interchangeability for Multiple Cell Applications |
| Wiring Code | GN +Output, WT -Output, BK -Input, RD +Input |
| Series | LC501 Series |
| Type | Cantilever Beam Load Cell |
| Load mode | Compression |
| Rated capacity | 100 lbf (445 N) |
| Excitation | 10 V DC, 15 V DC maximum |
| Rated output | 3 mV/V ±0.25% |
| Linearity | ±0.03% FSO |
| Hysteresis | ±0.05% FSO |
| Repeatability | ±0.02% FSO |
| Zero balance | ±1% FSO |
| Operating temperature range | -30 to 180°F (-34 to 82°C) |
| Compensated temperature range | 60 to 160°F (16 to 71°C) |
| Thermal effect on zero | ±0.001% FSO/°F (0.0018%/°C) |
| Thermal effect on span | ±0.001% FSO/°F (0.0018%/°C) |
| Safe overload | 150% of capacity |
| Ultimate overload | 300% of capacity |
| Input resistance | 360 Ω minimum |
| Output resistance | 350 ±10 Ω |
| Full scale deflection | 0.02" (0.5 mm) typical |
| Construction | 17-4 PH stainless steel |
| Calibration | 5-point NIST traceable certificate included |
| Cable | 15' (4.57 m) cable |
| Electrical connection | Cable (Cable) |
| Interchangeability | 0.25% Interchangeability for Multiple Cell Applications |
| Wiring Code | GN +Output, WT -Output, BK -Input, RD +Input |