With 0 to 100 %, -13 to 392°F (-25 to 200°C), 12 to 28 V DC, this dew point/humidity transmitter is used for compressed air monitoring and environmental chambers. It has dew point range of -76 to 104°F (-60 to 40°C).
With 0 to 100 %, -13 to 392°F (-25 to 200°C), 12 to 28 V DC, this dew point/humidity transmitter is used for compressed air monitoring and environmental chambers. It has dew point range of -76 to 104°F (-60 to 40°C).
The HX200 is a high accuracy loop powered calibrated dew point or humidity transmitter. The remote sensor is designed to work at temperatures as high as 392°F (392°F (200°C)). This high accuracy sensor is also built to withstand up to 750 psi (51.7 bar).
Features
Applications
| Series | HX200 Series |
| Type | dew point/humidity transmitter |
| Configuration | 0 % to 100 % |
| Range | -13 to 392°F (-13 to 392°F (-25 to 200°C)) |
| Supply voltage | 12 V DC to 28 V DC |
| Output | 4 mA to 20 mA |
| Configuration | NIST Traceable Calibration Certificate Included |
| Configuration | Selectable C/F |
| Dew Point Range | -76 to 104°F (-60 to 40°C) |
| Relative Humidity Range | 0 to 95% RH (non-condensing) |
| Dew Point Accuracy | ±1.0°C from -4 to 104°F (-20 to 40°C); ±3.0°C below -4°F (-20°C) |
| Relative Humidity Accuracy | ±1% RH from 59 to 104°F (15 to 40°C), 0 to 90% RH (non-condensing); ±2% RH below 59°F (15°C) or above 104°F (40°C) |
| Output | 4 to 20 mA loop powered, 2-wire 24 V DC (typical), 12 to 28 V DC |
| Maximum Operating Temperature | 392°F (200°C) (at 0% RH) |
| Maximum Sensor Pressure Rating | 750 psi (51.7 bar) |
| Display | 2 line LCD |
| Resolution | 0.1 |
| Temperature Sensor Body Material | 304 SS |
| Mesh Filter Top | Stainless Steel |
| Probe Length | 4" (10.16 cm) |
| Probe OD | 0.5" (1.27 cm) |
| Fitting | 1/2" (12.7 mm) NPT |
| Mounting Center | 3.1" (78.7 mm) |
| Dew Point | -76 to 104°F (-60 to 40°C) |
| Relative Humidity | 0 to 95% RH (non-condensing) |
| Single Output | 4 to 20 mA |
| Enclosure Dimensions | 3.5 x 2.5" (88.9 x 63.5 mm) |
| Weight | 4 lb (1.8 kg) |
| Series | HX200 Series |
| Type | dew point/humidity transmitter |
| Configuration | 0 % to 100 % |
| Range | -13 to 392°F (-13 to 392°F (-25 to 200°C)) |
| Supply voltage | 12 V DC to 28 V DC |
| Output | 4 mA to 20 mA |
| Configuration | NIST Traceable Calibration Certificate Included |
| Configuration | Selectable C/F |
| Dew Point Range | -76 to 104°F (-60 to 40°C) |
| Relative Humidity Range | 0 to 95% RH (non-condensing) |
| Dew Point Accuracy | ±1.0°C from -4 to 104°F (-20 to 40°C); ±3.0°C below -4°F (-20°C) |
| Relative Humidity Accuracy | ±1% RH from 59 to 104°F (15 to 40°C), 0 to 90% RH (non-condensing); ±2% RH below 59°F (15°C) or above 104°F (40°C) |
| Output | 4 to 20 mA loop powered, 2-wire 24 V DC (typical), 12 to 28 V DC |
| Maximum Operating Temperature | 392°F (200°C) (at 0% RH) |
| Maximum Sensor Pressure Rating | 750 psi (51.7 bar) |
| Display | 2 line LCD |
| Resolution | 0.1 |
| Temperature Sensor Body Material | 304 SS |
| Mesh Filter Top | Stainless Steel |
| Probe Length | 4" (10.16 cm) |
| Probe OD | 0.5" (1.27 cm) |
| Fitting | 1/2" (12.7 mm) NPT |
| Mounting Center | 3.1" (78.7 mm) |
| Dew Point | -76 to 104°F (-60 to 40°C) |
| Relative Humidity | 0 to 95% RH (non-condensing) |
| Single Output | 4 to 20 mA |
| Enclosure Dimensions | 3.5 x 2.5" (88.9 x 63.5 mm) |
| Weight | 4 lb (1.8 kg) |