Designed for measuring ac and dc current in electrical panels and circuits and checking for live wires with the non-contact voltage detector, this clamp meter provides 1500 A, AC/DC Voltage/Current, Resistance. It has display counts of Dual 40,000/4000 count backlit LCD.

Designed for measuring ac and dc current in electrical panels and circuits and checking for live wires with the non-contact voltage detector, this clamp meter provides 1500 A, AC/DC Voltage/Current, Resistance. It has display counts of Dual 40,000/4000 count backlit LCD.

Your Price $693.58 USD
Availability 2 to 3 Weeks
Quantity

OMEGA HHM-MA1500 Offers

The HHM-MA1500 is a true RMS clamp meter. This meter measures AC current, DC current, AC/DC voltage, resistance, capacitance, frequency, diode test, duty cycle and continuity.

The molded case is designed for heavy-duty use. The integrated non-contact voltage detector quickly checks for the presence of live wires before testing needs to be started.

Features

  • True rms for accurate readings of non-sinusoidal waveforms
  • Built-in non-contact voltage detector with led alert
  • 2.0" (52 mm) jaw size for conductors up to 500mcm
  • Dual 40,000/4000 count, backlit lcd display
  • Includes multimeter functions
  • Inrush function captures transients during motor startups
  • Relative mode for capacitance zero and offset adjustment
  • Data hold, peak hold, minimum/max, and auto power off

Applications

  • Measuring AC and DC current in electrical panels and circuits
  • Troubleshooting motor startup inrush currents
  • Checking for live wires with the non-contact voltage detector
  • Measuring voltage, resistance, capacitance and frequency in maintenance work
  • Type k thermocouple temperature measurement during electrical diagnostics

OMEGA HHM-MA1500 Specifications

Series HHM-MA1500
Type clamp meter
Configuration 1500 A
Configuration AC/DC Voltage/Current
Configuration Resistance
Configuration Capacitance
Configuration Frequency
Configuration K Temperature
Configuration Battery
Clamp Jaw Opening 2.0" (52 mm) approximate
Display Counts Dual 40,000/4000 count backlit LCD
Measurement Rate 2 readings per second, nominal
Peak Detector >1ms
Input Impedance 10MΩ (V DC and V AC)
AC Bandwidth 50 to 400 Hz (AAC and V AC)
AC Response True RMS (AAC and V AC)
Crest Factor 3.0 in 400A range, 1.4 in 1000A range (50/60 Hz and 5% to 100% of Range)
AC Current (True RMS) 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.8%+30d)
DC Current 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.5%+30d)
AC Voltage (True RMS) 400.00 mV, 4.000 V, 40.00 V, 750.0 V, maximum resolution 0.01mV, basic accuracy ±(1.0%+30d)
DC Voltage 400.00 mV, 4.0000 V, 40.000 V, 1000.0 V, maximum resolution 0.01mV, basic accuracy ±(0.1%+4d)
Resistance 400.00 Ω, 4.0000 kΩ, 40.000 kΩ, 400.00 kΩ, 4.0000 kΩ, 40.000M Ω, maximum resolution 0.01 Ω, basic accuracy ±(0.5%+9d)
Frequency 40 Hz to 40 MHz, maximum resolution 0.001 Hz, basic accuracy ±(0.3%+2d)
Capacitance 400.00nF, 4000nF, 40.00μF, 400.0μF, 4.000mF, 20.00mF, 40.00mF, maximum resolution 0.01nF, basic accuracy ±(3.5%+10d)
Temperature -148 to 1832°F (-100 to 1000°C), maximum resolution 0.1°, basic accuracy ±(1%+4.5°F/2.5°C)
Thermocouple Sensor Type K thermocouple required
Duty Cycle 10.0 to 95.0%, maximum resolution 0.1%, basic accuracy ±(1.0%+2d)
Diode Test current of 0.3mA typical; Open circuit voltage 2.8 V DC typical
Continuity Threshold 25 to 60 Ω; Test current < 0.5mA
Power 9 V battery (included)
Low Battery Indication Battery symbol is displayed
Over-Range Indication OL' display
Auto Power Off After approximately 30 minutes
Operating Temperature 41 to 104°F (5 to 40°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Operating Humidity Maximum 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C)
Storage Humidity <80%
Operating Altitude 6562' (2000 m) maximum
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001), Overvoltage Category IV 600 V and Category III 1000 V, Pollution Degree 2
Jaw Capacity 2.0" (52 mm) jaw size for conductors up to 500MCM
Non-Contact Voltage Detector Built-In Non-Contact Voltage Detector with LED Alert
Included Comes complete with test leads, Type K bead wire temperature probe, 9 V battery, carrying case and operator's manual
Dimensions 11.57 x 4.13 x 1.85" (294 x 105 x 47 mm)
Weight 18.9 oz (536 g)

What's included with the OMEGA HHM-MA1500

  • Omega HHM-MA1500 Clamp Meter, AC/DC voltage/current, 1500 A

Ask a question about Omega HHM-MA1500 Clamp Meter, AC/DC voltage/current, 1500 A

Customer Reviews for the OMEGA HHM-MA1500

OMEGA HHM-MA1500 Offers

The HHM-MA1500 is a true RMS clamp meter. This meter measures AC current, DC current, AC/DC voltage, resistance, capacitance, frequency, diode test, duty cycle and continuity.

The molded case is designed for heavy-duty use. The integrated non-contact voltage detector quickly checks for the presence of live wires before testing needs to be started.

Features

  • True rms for accurate readings of non-sinusoidal waveforms
  • Built-in non-contact voltage detector with led alert
  • 2.0" (52 mm) jaw size for conductors up to 500mcm
  • Dual 40,000/4000 count, backlit lcd display
  • Includes multimeter functions
  • Inrush function captures transients during motor startups
  • Relative mode for capacitance zero and offset adjustment
  • Data hold, peak hold, minimum/max, and auto power off

Applications

  • Measuring AC and DC current in electrical panels and circuits
  • Troubleshooting motor startup inrush currents
  • Checking for live wires with the non-contact voltage detector
  • Measuring voltage, resistance, capacitance and frequency in maintenance work
  • Type k thermocouple temperature measurement during electrical diagnostics

OMEGA HHM-MA1500 Specifications

Series HHM-MA1500
Type clamp meter
Configuration 1500 A
Configuration AC/DC Voltage/Current
Configuration Resistance
Configuration Capacitance
Configuration Frequency
Configuration K Temperature
Configuration Battery
Clamp Jaw Opening 2.0" (52 mm) approximate
Display Counts Dual 40,000/4000 count backlit LCD
Measurement Rate 2 readings per second, nominal
Peak Detector >1ms
Input Impedance 10MΩ (V DC and V AC)
AC Bandwidth 50 to 400 Hz (AAC and V AC)
AC Response True RMS (AAC and V AC)
Crest Factor 3.0 in 400A range, 1.4 in 1000A range (50/60 Hz and 5% to 100% of Range)
AC Current (True RMS) 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.8%+30d)
DC Current 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.5%+30d)
AC Voltage (True RMS) 400.00 mV, 4.000 V, 40.00 V, 750.0 V, maximum resolution 0.01mV, basic accuracy ±(1.0%+30d)
DC Voltage 400.00 mV, 4.0000 V, 40.000 V, 1000.0 V, maximum resolution 0.01mV, basic accuracy ±(0.1%+4d)
Resistance 400.00 Ω, 4.0000 kΩ, 40.000 kΩ, 400.00 kΩ, 4.0000 kΩ, 40.000M Ω, maximum resolution 0.01 Ω, basic accuracy ±(0.5%+9d)
Frequency 40 Hz to 40 MHz, maximum resolution 0.001 Hz, basic accuracy ±(0.3%+2d)
Capacitance 400.00nF, 4000nF, 40.00μF, 400.0μF, 4.000mF, 20.00mF, 40.00mF, maximum resolution 0.01nF, basic accuracy ±(3.5%+10d)
Temperature -148 to 1832°F (-100 to 1000°C), maximum resolution 0.1°, basic accuracy ±(1%+4.5°F/2.5°C)
Thermocouple Sensor Type K thermocouple required
Duty Cycle 10.0 to 95.0%, maximum resolution 0.1%, basic accuracy ±(1.0%+2d)
Diode Test current of 0.3mA typical; Open circuit voltage 2.8 V DC typical
Continuity Threshold 25 to 60 Ω; Test current < 0.5mA
Power 9 V battery (included)
Low Battery Indication Battery symbol is displayed
Over-Range Indication OL' display
Auto Power Off After approximately 30 minutes
Operating Temperature 41 to 104°F (5 to 40°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Operating Humidity Maximum 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C)
Storage Humidity <80%
Operating Altitude 6562' (2000 m) maximum
Safety For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001), Overvoltage Category IV 600 V and Category III 1000 V, Pollution Degree 2
Jaw Capacity 2.0" (52 mm) jaw size for conductors up to 500MCM
Non-Contact Voltage Detector Built-In Non-Contact Voltage Detector with LED Alert
Included Comes complete with test leads, Type K bead wire temperature probe, 9 V battery, carrying case and operator's manual
Dimensions 11.57 x 4.13 x 1.85" (294 x 105 x 47 mm)
Weight 18.9 oz (536 g)