Designed for measuring ac and dc current in electrical panels and circuits and checking for live wires with the non-contact voltage detector, this clamp meter provides 1500 A, AC/DC Voltage/Current, Resistance. It has display counts of Dual 40,000/4000 count backlit LCD.
Designed for measuring ac and dc current in electrical panels and circuits and checking for live wires with the non-contact voltage detector, this clamp meter provides 1500 A, AC/DC Voltage/Current, Resistance. It has display counts of Dual 40,000/4000 count backlit LCD.
The HHM-MA1500 is a true RMS clamp meter. This meter measures AC current, DC current, AC/DC voltage, resistance, capacitance, frequency, diode test, duty cycle and continuity.
The molded case is designed for heavy-duty use. The integrated non-contact voltage detector quickly checks for the presence of live wires before testing needs to be started.
Features
Applications
| Series | HHM-MA1500 |
| Type | clamp meter |
| Configuration | 1500 A |
| Configuration | AC/DC Voltage/Current |
| Configuration | Resistance |
| Configuration | Capacitance |
| Configuration | Frequency |
| Configuration | K Temperature |
| Configuration | Battery |
| Clamp Jaw Opening | 2.0" (52 mm) approximate |
| Display Counts | Dual 40,000/4000 count backlit LCD |
| Measurement Rate | 2 readings per second, nominal |
| Peak Detector | >1ms |
| Input Impedance | 10MΩ (V DC and V AC) |
| AC Bandwidth | 50 to 400 Hz (AAC and V AC) |
| AC Response | True RMS (AAC and V AC) |
| Crest Factor | 3.0 in 400A range, 1.4 in 1000A range (50/60 Hz and 5% to 100% of Range) |
| AC Current (True RMS) | 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.8%+30d) |
| DC Current | 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.5%+30d) |
| AC Voltage (True RMS) | 400.00 mV, 4.000 V, 40.00 V, 750.0 V, maximum resolution 0.01mV, basic accuracy ±(1.0%+30d) |
| DC Voltage | 400.00 mV, 4.0000 V, 40.000 V, 1000.0 V, maximum resolution 0.01mV, basic accuracy ±(0.1%+4d) |
| Resistance | 400.00 Ω, 4.0000 kΩ, 40.000 kΩ, 400.00 kΩ, 4.0000 kΩ, 40.000M Ω, maximum resolution 0.01 Ω, basic accuracy ±(0.5%+9d) |
| Frequency | 40 Hz to 40 MHz, maximum resolution 0.001 Hz, basic accuracy ±(0.3%+2d) |
| Capacitance | 400.00nF, 4000nF, 40.00μF, 400.0μF, 4.000mF, 20.00mF, 40.00mF, maximum resolution 0.01nF, basic accuracy ±(3.5%+10d) |
| Temperature | -148 to 1832°F (-100 to 1000°C), maximum resolution 0.1°, basic accuracy ±(1%+4.5°F/2.5°C) |
| Thermocouple Sensor | Type K thermocouple required |
| Duty Cycle | 10.0 to 95.0%, maximum resolution 0.1%, basic accuracy ±(1.0%+2d) |
| Diode Test | current of 0.3mA typical; Open circuit voltage 2.8 V DC typical |
| Continuity Threshold | 25 to 60 Ω; Test current < 0.5mA |
| Power | 9 V battery (included) |
| Low Battery Indication | Battery symbol is displayed |
| Over-Range Indication | OL' display |
| Auto Power Off | After approximately 30 minutes |
| Operating Temperature | 41 to 104°F (5 to 40°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Operating Humidity | Maximum 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C) |
| Storage Humidity | <80% |
| Operating Altitude | 6562' (2000 m) maximum |
| Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001), Overvoltage Category IV 600 V and Category III 1000 V, Pollution Degree 2 |
| Jaw Capacity | 2.0" (52 mm) jaw size for conductors up to 500MCM |
| Non-Contact Voltage Detector | Built-In Non-Contact Voltage Detector with LED Alert |
| Included | Comes complete with test leads, Type K bead wire temperature probe, 9 V battery, carrying case and operator's manual |
| Dimensions | 11.57 x 4.13 x 1.85" (294 x 105 x 47 mm) |
| Weight | 18.9 oz (536 g) |
| Series | HHM-MA1500 |
| Type | clamp meter |
| Configuration | 1500 A |
| Configuration | AC/DC Voltage/Current |
| Configuration | Resistance |
| Configuration | Capacitance |
| Configuration | Frequency |
| Configuration | K Temperature |
| Configuration | Battery |
| Clamp Jaw Opening | 2.0" (52 mm) approximate |
| Display Counts | Dual 40,000/4000 count backlit LCD |
| Measurement Rate | 2 readings per second, nominal |
| Peak Detector | >1ms |
| Input Impedance | 10MΩ (V DC and V AC) |
| AC Bandwidth | 50 to 400 Hz (AAC and V AC) |
| AC Response | True RMS (AAC and V AC) |
| Crest Factor | 3.0 in 400A range, 1.4 in 1000A range (50/60 Hz and 5% to 100% of Range) |
| AC Current (True RMS) | 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.8%+30d) |
| DC Current | 400.00A, 1500.0A, maximum resolution 0.01A, basic accuracy ±(2.5%+30d) |
| AC Voltage (True RMS) | 400.00 mV, 4.000 V, 40.00 V, 750.0 V, maximum resolution 0.01mV, basic accuracy ±(1.0%+30d) |
| DC Voltage | 400.00 mV, 4.0000 V, 40.000 V, 1000.0 V, maximum resolution 0.01mV, basic accuracy ±(0.1%+4d) |
| Resistance | 400.00 Ω, 4.0000 kΩ, 40.000 kΩ, 400.00 kΩ, 4.0000 kΩ, 40.000M Ω, maximum resolution 0.01 Ω, basic accuracy ±(0.5%+9d) |
| Frequency | 40 Hz to 40 MHz, maximum resolution 0.001 Hz, basic accuracy ±(0.3%+2d) |
| Capacitance | 400.00nF, 4000nF, 40.00μF, 400.0μF, 4.000mF, 20.00mF, 40.00mF, maximum resolution 0.01nF, basic accuracy ±(3.5%+10d) |
| Temperature | -148 to 1832°F (-100 to 1000°C), maximum resolution 0.1°, basic accuracy ±(1%+4.5°F/2.5°C) |
| Thermocouple Sensor | Type K thermocouple required |
| Duty Cycle | 10.0 to 95.0%, maximum resolution 0.1%, basic accuracy ±(1.0%+2d) |
| Diode Test | current of 0.3mA typical; Open circuit voltage 2.8 V DC typical |
| Continuity Threshold | 25 to 60 Ω; Test current < 0.5mA |
| Power | 9 V battery (included) |
| Low Battery Indication | Battery symbol is displayed |
| Over-Range Indication | OL' display |
| Auto Power Off | After approximately 30 minutes |
| Operating Temperature | 41 to 104°F (5 to 40°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Operating Humidity | Maximum 80% up to 87°F (31°C) decreasing linearly to 50% at 104°F (40°C) |
| Storage Humidity | <80% |
| Operating Altitude | 6562' (2000 m) maximum |
| Safety | For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (2001): EN61010-1 (2001), Overvoltage Category IV 600 V and Category III 1000 V, Pollution Degree 2 |
| Jaw Capacity | 2.0" (52 mm) jaw size for conductors up to 500MCM |
| Non-Contact Voltage Detector | Built-In Non-Contact Voltage Detector with LED Alert |
| Included | Comes complete with test leads, Type K bead wire temperature probe, 9 V battery, carrying case and operator's manual |
| Dimensions | 11.57 x 4.13 x 1.85" (294 x 105 x 47 mm) |
| Weight | 18.9 oz (536 g) |