Made for inline liquid flow measurement, this turbine flow meter measures 0.176 to 1.76 GPM (0.6662 to 6.662 LPM) through a 1/2" NPT male connection. It produces a 4-20 mA output with ±0.5% accuracy and uses 304, 316, and CD4MCU stainless steel with tungsten carbide. Works great for process liquid measurement.
Made for inline liquid flow measurement, this turbine flow meter measures 0.176 to 1.76 GPM (0.6662 to 6.662 LPM) through a 1/2" NPT male connection. It produces a 4-20 mA output with ±0.5% accuracy and uses 304, 316, and CD4MCU stainless steel with tungsten carbide. Works great for process liquid measurement.
When liquid flows through the casing of sensor, the impulse of fluid will provide the blade with a rotation moment as there is an angle between the blade of impeller and the flow direction. The blade will rotate as the friction moment and the fluid resistance are overcome and it will reach a stable speed when the moments are at balance.
Under certain conditions, the rotation speed of blade will be in direct proportion to the flow velocity. Due to the magnetic conductivity of blade, when located in the magnetic field generated by signal detector (made of permanent magnet steel and coils), the rotating blade will cut the magnetic lines and periodically change the flux through the coil, thereby inducing electrical impulse signals at both ends of the coil.
The induced signals, after amplified and rectified by amplifier, will form a continuous rectangular impulse wave with certain amplitude which may be remotely transmitted to display instrument indicating the instant flow and the cumulative flow of fluid. Within a certain range of flow, the impulse frequency f is in direct proportion to the instant flow of fluid flowing through the sensor.
Features
Applications
| Body | 304 or 316 stainless steel |
| Rotor | CD4MCU stainless steel |
| Rotor support and bearing | 316 stainless steel |
| Rotor shaft | Tungsten carbide |
| Temperature | -4°F to 248°F (-20°C to 120°C) |
| Pressure | 913.5 psi for all NPT meters up to 1" 362.5 psi for 1-1/4", 1-1/2", 2" male NPT 232 psi for 2-1/2", 3", 4" male NPT |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% |
| Calibration | Water (CNAS Traceable Calibration) |
| Output | 4 mA to 20 mA |
| Connection | NPT 1/2" |
| Dimensions | 8.86" (225 mm) Height: 5.55" (141 mm) |
| Body | 304 or 316 stainless steel |
| Rotor | CD4MCU stainless steel |
| Rotor support and bearing | 316 stainless steel |
| Rotor shaft | Tungsten carbide |
| Temperature | -4°F to 248°F (-20°C to 120°C) |
| Pressure | 913.5 psi for all NPT meters up to 1" 362.5 psi for 1-1/4", 1-1/2", 2" male NPT 232 psi for 2-1/2", 3", 4" male NPT |
| Accuracy | ±0.5% of reading |
| Repeatability | ±0.1% |
| Calibration | Water (CNAS Traceable Calibration) |
| Output | 4 mA to 20 mA |
| Connection | NPT 1/2" |
| Dimensions | 8.86" (225 mm) Height: 5.55" (141 mm) |