This turbine flow meter measures liquid flow from 0.3 to 3 GPM at ±1% accuracy. It has a 1/2" (12.7 mm) connection. It suits industrial water measurement and low viscosity fluid metering.
This turbine flow meter measures liquid flow from 0.3 to 3 GPM at ±1% accuracy. It has a 1/2" (12.7 mm) connection. It suits industrial water measurement and low viscosity fluid metering.
The FTB-1300 Series of turbine flow meters are designed for industrial and laboratory measurement of water, solvents and other low viscosity fluids. The FTB-1300 Series turbine flow meters feature a 316 stainless steel body and a tungsten carbide bearing. They offer good accuracy and reliability with very little pressure drop.
The standard turbine flow meters feature threaded end connections. The FTB-1300 series of turbine flow meters is designed with a wear resistant rotor assembly to provide trouble free operation and a long service life.
Features
Applications
| Series | FTB-1300 Series |
| Type | turbine flow meter |
| Media | Liquid |
| Flow range | 0.3 to 3 GPM |
| Accuracy | ±1% full scale |
| Process connection | 1/2" (12.7 mm) |
| Output | 4 to 20 mA |
| Accuracy | ±1% reading |
| Maximum Pressure | 5000 psi (345 bar) |
| Wetted Materials | Stainless Steel (316L, 303 and 1.4122) and carbide with nickel binder |
| Supply Voltage (Square Wave Models) | 10 to 28 V DC |
| Frequency Output (Square Wave Models) | Flow dependent, up to 2000 Hz |
| Output (FTB-1310 Models) | 4 to 20 mA |
| Temperature Range | -40 to 185°F (-40 to 85°C) |
| Cable Length | 24" (60 cm) |
| Linearity (Current FTB-1310 Models) | ±0.01% of reading |
| Pressure Max | 5000 psi (345 bar) |
| Supply Current (Square Wave) | 8 mA @ 12 V DC, 12 mA @ 24 V DC |
| Duty Signal (Square Wave) | 50% ±15% |
| Minimum Signal (Square Wave) | 0.5 Hz |
| Driving Capacity (Square Wave) | 50 mA Max resistive load |
| Output Impedance (Square Wave) | ~ 40 Ω, analog switch and self-resetting fuse |
| Input (Current FTB-1310 Models) | 0.25 Hz to 5 KHz |
| Update Time (Current FTB-1310 Models) | 1/F + 25 msec |
| Amplitude (Current FTB-1310 Models) | 1 V p-p to 40 V p-p |
| Enclosure Certifications (FTB-1310 Series) | NEC Class I Groups C, D; Class II Groups E, F, G |
| Series | FTB-1300 Series |
| Type | turbine flow meter |
| Media | Liquid |
| Flow range | 0.3 to 3 GPM |
| Accuracy | ±1% full scale |
| Process connection | 1/2" (12.7 mm) |
| Output | 4 to 20 mA |
| Accuracy | ±1% reading |
| Maximum Pressure | 5000 psi (345 bar) |
| Wetted Materials | Stainless Steel (316L, 303 and 1.4122) and carbide with nickel binder |
| Supply Voltage (Square Wave Models) | 10 to 28 V DC |
| Frequency Output (Square Wave Models) | Flow dependent, up to 2000 Hz |
| Output (FTB-1310 Models) | 4 to 20 mA |
| Temperature Range | -40 to 185°F (-40 to 85°C) |
| Cable Length | 24" (60 cm) |
| Linearity (Current FTB-1310 Models) | ±0.01% of reading |
| Pressure Max | 5000 psi (345 bar) |
| Supply Current (Square Wave) | 8 mA @ 12 V DC, 12 mA @ 24 V DC |
| Duty Signal (Square Wave) | 50% ±15% |
| Minimum Signal (Square Wave) | 0.5 Hz |
| Driving Capacity (Square Wave) | 50 mA Max resistive load |
| Output Impedance (Square Wave) | ~ 40 Ω, analog switch and self-resetting fuse |
| Input (Current FTB-1310 Models) | 0.25 Hz to 5 KHz |
| Update Time (Current FTB-1310 Models) | 1/F + 25 msec |
| Amplitude (Current FTB-1310 Models) | 1 V p-p to 40 V p-p |
| Enclosure Certifications (FTB-1310 Series) | NEC Class I Groups C, D; Class II Groups E, F, G |