This gas mass flow meter and controller measures gas flow from 0.15 to 15 SLM at ±1% accuracy. It has a 1/4" (6.3 mm) NPT Female connection rated to 250 psi (17.24 bar) and 122°F (50°C). It suits air flow measurement and clean gas mass flow measurement.
This gas mass flow meter and controller measures gas flow from 0.15 to 15 SLM at ±1% accuracy. It has a 1/4" (6.3 mm) NPT Female connection rated to 250 psi (17.24 bar) and 122°F (50°C). It suits air flow measurement and clean gas mass flow measurement.
The FMA-A2000 Series electronic mass flow meters/controllers provide high performance, versatility, and state-of-the-art design in one compact package. The FMA-A2000 uses capillary-type thermal technology to directly measure mass flow of gases. No temperature, pressure, or square root corrections are required.
Features
Applications
| Series | FMA-A2000 Series |
| Type | gas mass flow meter and controller |
| Media | Gas |
| Flow range | 0.15 to 15 SLM |
| Accuracy | ±1% full scale |
| Maximum pressure | 250 psi (17.24 bar) |
| Process connection | 1/4" (6.3 mm) NPT Female |
| Output | 0 V DC to 5 V DC |
| Maximum temperature | 122°F (50°C) |
| Accuracy | ±1% of full scale including linearity |
| Repeatability | ±0.15% full scale or better |
| Turndown Ratio | 4.16736111111111 |
| Response Time | 5 seconds |
| Temperature Coefficient | 0.05% full scale per 1°C or better |
| Pressure Coefficient | 0.01% full scale per psi or better |
| Maximum Gas Pressure (Polyacetal) | 250 psig (17.2 bar) |
| Maximum Gas Pressure (316 SS) | 500 psig (34.5 bar) |
| Leak Integrity | 1 x 10-6 cc/min of He or better |
| Control Signal | 0 to 5 V DC |
| Output Signal | Linear 0 to 5 V DC, 1000 Ω minimum load, 4 to 20 mA, 500 Ω loop resistance |
| Input/Output Connection | 9-pin sub-D connector |
| Gas Ambient Temperature | 32 to 122°F (0 to 50°C) |
| Wetted Parts (Standard) | Polyacetal, FKM O-rings |
| Wetted Parts (Optional) | 316 SS, FKM O-rings |
| Gas Compatibility | Compatible with most non-corrosive gases; controller ranges specified for nitrogen or air at 20 psig (1.38 bar) |
| Minimum Pressure Requirements | Meters: 1 inch of H2O; Controllers Up to 1 SLM: 1 psi (0.07 bar); Controllers Greater than 20 SLM: 20 psi (1.38 bar) |
| Differential Pressure for Mass Flow Controllers | <5 LPM, 5 to 50 psi (0.34 to 3.45 bar) standard; >5 LPM, 20 to 40 psi (1.38 to 2.76 bar) standard |
| Control Valve | Electromagnetic, normally closed |
| Mounting Threads | 316 SS Body: 6/32" (4.8 mm) thread; Polyacetal: Self tap #4/6 screw |
| Input Power (Meters) | 24 V DC @ 150 mA, 115 V AC, 220 V AC with AC adaptor |
| Input Power (Controller) | 24 V DC @ 300 mA, 115 V AC, 220 V AC with AC adaptor |
| Display | LCD (FMA-A2300/2400 Series come with LCD display) |
| Weight | 2.75 lb (1.25 kg) with power supply |
| Series | FMA-A2000 Series |
| Type | gas mass flow meter and controller |
| Media | Gas |
| Flow range | 0.15 to 15 SLM |
| Accuracy | ±1% full scale |
| Maximum pressure | 250 psi (17.24 bar) |
| Process connection | 1/4" (6.3 mm) NPT Female |
| Output | 0 V DC to 5 V DC |
| Maximum temperature | 122°F (50°C) |
| Accuracy | ±1% of full scale including linearity |
| Repeatability | ±0.15% full scale or better |
| Turndown Ratio | 4.16736111111111 |
| Response Time | 5 seconds |
| Temperature Coefficient | 0.05% full scale per 1°C or better |
| Pressure Coefficient | 0.01% full scale per psi or better |
| Maximum Gas Pressure (Polyacetal) | 250 psig (17.2 bar) |
| Maximum Gas Pressure (316 SS) | 500 psig (34.5 bar) |
| Leak Integrity | 1 x 10-6 cc/min of He or better |
| Control Signal | 0 to 5 V DC |
| Output Signal | Linear 0 to 5 V DC, 1000 Ω minimum load, 4 to 20 mA, 500 Ω loop resistance |
| Input/Output Connection | 9-pin sub-D connector |
| Gas Ambient Temperature | 32 to 122°F (0 to 50°C) |
| Wetted Parts (Standard) | Polyacetal, FKM O-rings |
| Wetted Parts (Optional) | 316 SS, FKM O-rings |
| Gas Compatibility | Compatible with most non-corrosive gases; controller ranges specified for nitrogen or air at 20 psig (1.38 bar) |
| Minimum Pressure Requirements | Meters: 1 inch of H2O; Controllers Up to 1 SLM: 1 psi (0.07 bar); Controllers Greater than 20 SLM: 20 psi (1.38 bar) |
| Differential Pressure for Mass Flow Controllers | <5 LPM, 5 to 50 psi (0.34 to 3.45 bar) standard; >5 LPM, 20 to 40 psi (1.38 to 2.76 bar) standard |
| Control Valve | Electromagnetic, normally closed |
| Mounting Threads | 316 SS Body: 6/32" (4.8 mm) thread; Polyacetal: Self tap #4/6 screw |
| Input Power (Meters) | 24 V DC @ 150 mA, 115 V AC, 220 V AC with AC adaptor |
| Input Power (Controller) | 24 V DC @ 300 mA, 115 V AC, 220 V AC with AC adaptor |
| Display | LCD (FMA-A2300/2400 Series come with LCD display) |
| Weight | 2.75 lb (1.25 kg) with power supply |