With DC Supply, -40 to 100 mV I/P, Bridge, this DIN rail signal conditioner is used for tank filling and draining and measurement of cable tensile force. It has supply voltage of 19.2...28.8 V DC.
With DC Supply, -40 to 100 mV I/P, Bridge, this DIN rail signal conditioner is used for tank filling and draining and measurement of cable tensile force. It has supply voltage of 19.2...28.8 V DC.
The DRST-BG converts bipolar mV signals from transducers supplied directly by the module to standard current / voltage signals. The DRST-BG is suitable for load cell applications.
By way of the relative calibration function the scale can be tared, i.e. 0 and 100% calibrated without the need of the equivalent load.
Features
Applications
| Series | DRST-BG Series |
| Type | DIN rail signal conditioner |
| Supply voltage | DC Supply |
| Input | -40 mV to 100 mV I/P |
| Configuration | Bridge |
| Input | Strain I/P & Process O/P Class |
| Supply voltage | 19.2...28.8 V DC |
| Internal consumption | 2.2 W |
| Maximum consumption | 7.2 W |
| Transducer supply | 5...13 V DC |
| Transducer supply load (maximum) | 230 mA |
| Measurement range (mV input) | -40...100 mV |
| Minimum measurement range (span) | 10 mV |
| Input resistance | > 10 MΩ |
| Current output signal range | 0...20 mA |
| Voltage output signal range | 0...10 V DC |
| Signal / noise ratio | Minimum 60 dB |
| Signal dynamics, input / output | 17 bit / 16 bit |
| Updating time | 20 ms |
| Response time, programmable | 0.06...999 s |
| Temperature coefficient | < ±0.01% of span / °C |
| Linearity error | ≤ ±0.1% of span |
| Effect of supply voltage change | < ±0.002% of span / %V |
| EMC immunity influence | < ±0.5% of span |
| Protection degree | IP50 |
| Specifications range | -4 to 140°F (-20 to 60°C) |
| Calibration temperature | 68 to 82°F (20 to 28°C) |
| Relative air humidity | < 95% RH (non-condensing) |
| Product Type | mV to current/voltage transmitter / load cell amplifier |
| Max. Consumption | 7.2 W |
| Signal Dynamics, Input | 17 bit |
| Signal Dynamics, Output | 16 bit |
| mV Measurement Range | -40...100 mV |
| Min. Measurement Range (Span) | 10 mV |
| Max. Offset | 70% of selected maximum. value |
| Input in Relation to Supply Gnd | > -5 V and < +10 V |
| Max. Cable Resistance per Wire | 15 Ω |
| Suppression of Transducer Cable Resistance | > 300 |
| Overrange | 0...999% of selected measurement range |
| Taring Input | PNP / NPN / Front Key |
| Digital Input NPN Pull Up | 24 VDC / 6.9 mA |
| Digital Input PNP Pull Down | 0 VDC / 6.9 mA |
| Digital Input Trig Level Low | < 6 VDC |
| Digital Input Trig Level High | > 10.5 VDC |
| Digital Input Pulse Width | > 30 ms |
| Current Output Min. Signal Range (Span) | 5 mA |
| Current Output Max. Offset | 50% of selected maximum. value |
| Current Output Load (maximum.) | 20 mA / 600 Ω / 12 VDC |
| Current Output Load Stability | < ±0.01% of span/100 Ω |
| Current Limit | < 23 mA |
| Voltage Output Min. Signal Range (Span) | 250 mVDC |
| Voltage Output Max. Offset | 50% of selected maximum. value |
| Voltage Output Load (minimum.) | 500 kΩ |
| Voltage Limit | < 11.5 VDC |
| Hardware-Programmable Output Ranges | 0...10 mA, 0...20 mA, 0...500 mV, 0...1000 mV, 0...5 V, 0...10 V (JP1/JP2 jumpers) |
| User Interface | 3-digit display and 3 front function keys |
| Front Error LED | Red LED flashes at incorrect output / overrange saturation |
| Common Mode Frequency Suppression | 50 or 60 Hz selectable |
| Observed Authority Requirements | EMC 2004/108/EC EN 61326-1; EAC TR-CU 020/2011 EN 61326-1 |
| Dimensions (H x W x D) | 3.17 x 1.40 x 3.33" (80.5 x 35.5 x 84.5 mm) |
| Weight | 4.59 oz (130 g) |
Click on a category to view a selection of compatible accessories with the Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output.
| Series | DRST-BG Series |
| Type | DIN rail signal conditioner |
| Supply voltage | DC Supply |
| Input | -40 mV to 100 mV I/P |
| Configuration | Bridge |
| Input | Strain I/P & Process O/P Class |
| Supply voltage | 19.2...28.8 V DC |
| Internal consumption | 2.2 W |
| Maximum consumption | 7.2 W |
| Transducer supply | 5...13 V DC |
| Transducer supply load (maximum) | 230 mA |
| Measurement range (mV input) | -40...100 mV |
| Minimum measurement range (span) | 10 mV |
| Input resistance | > 10 MΩ |
| Current output signal range | 0...20 mA |
| Voltage output signal range | 0...10 V DC |
| Signal / noise ratio | Minimum 60 dB |
| Signal dynamics, input / output | 17 bit / 16 bit |
| Updating time | 20 ms |
| Response time, programmable | 0.06...999 s |
| Temperature coefficient | < ±0.01% of span / °C |
| Linearity error | ≤ ±0.1% of span |
| Effect of supply voltage change | < ±0.002% of span / %V |
| EMC immunity influence | < ±0.5% of span |
| Protection degree | IP50 |
| Specifications range | -4 to 140°F (-20 to 60°C) |
| Calibration temperature | 68 to 82°F (20 to 28°C) |
| Relative air humidity | < 95% RH (non-condensing) |
| Product Type | mV to current/voltage transmitter / load cell amplifier |
| Max. Consumption | 7.2 W |
| Signal Dynamics, Input | 17 bit |
| Signal Dynamics, Output | 16 bit |
| mV Measurement Range | -40...100 mV |
| Min. Measurement Range (Span) | 10 mV |
| Max. Offset | 70% of selected maximum. value |
| Input in Relation to Supply Gnd | > -5 V and < +10 V |
| Max. Cable Resistance per Wire | 15 Ω |
| Suppression of Transducer Cable Resistance | > 300 |
| Overrange | 0...999% of selected measurement range |
| Taring Input | PNP / NPN / Front Key |
| Digital Input NPN Pull Up | 24 VDC / 6.9 mA |
| Digital Input PNP Pull Down | 0 VDC / 6.9 mA |
| Digital Input Trig Level Low | < 6 VDC |
| Digital Input Trig Level High | > 10.5 VDC |
| Digital Input Pulse Width | > 30 ms |
| Current Output Min. Signal Range (Span) | 5 mA |
| Current Output Max. Offset | 50% of selected maximum. value |
| Current Output Load (maximum.) | 20 mA / 600 Ω / 12 VDC |
| Current Output Load Stability | < ±0.01% of span/100 Ω |
| Current Limit | < 23 mA |
| Voltage Output Min. Signal Range (Span) | 250 mVDC |
| Voltage Output Max. Offset | 50% of selected maximum. value |
| Voltage Output Load (minimum.) | 500 kΩ |
| Voltage Limit | < 11.5 VDC |
| Hardware-Programmable Output Ranges | 0...10 mA, 0...20 mA, 0...500 mV, 0...1000 mV, 0...5 V, 0...10 V (JP1/JP2 jumpers) |
| User Interface | 3-digit display and 3 front function keys |
| Front Error LED | Red LED flashes at incorrect output / overrange saturation |
| Common Mode Frequency Suppression | 50 or 60 Hz selectable |
| Observed Authority Requirements | EMC 2004/108/EC EN 61326-1; EAC TR-CU 020/2011 EN 61326-1 |
| Dimensions (H x W x D) | 3.17 x 1.40 x 3.33" (80.5 x 35.5 x 84.5 mm) |
| Weight | 4.59 oz (130 g) |
Click on a category to view a selection of compatible accessories with the Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output.