Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output

Model: DRST-BG

Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output

Model: DRST-BG

With DC Supply, -40 to 100 mV I/P, Bridge, this DIN rail signal conditioner is used for tank filling and draining and measurement of cable tensile force. It has supply voltage of 19.2...28.8 V DC.

With DC Supply, -40 to 100 mV I/P, Bridge, this DIN rail signal conditioner is used for tank filling and draining and measurement of cable tensile force. It has supply voltage of 19.2...28.8 V DC.

Sale Price $628.69 USD
Regular Price $665.28 USD
Availability 2 to 3 Weeks
Quantity

OMEGA DRST-BG Offers

The DRST-BG converts bipolar mV signals from transducers supplied directly by the module to standard current / voltage signals. The DRST-BG is suitable for load cell applications.

By way of the relative calibration function the scale can be tared, i.e. 0 and 100% calibrated without the need of the equivalent load.

Features

  • Programming, process monitoring and diagnostics via DRSL-DISPLAY
  • Load cell amplifier
  • Mv to current/voltage conversion
  • Front-programmable/led display
  • Relative calibration of input span
  • Npn/pnp input for external taring
  • Supply for standard transducers

Applications

  • Providing local readout of process values via the detachable DRSL-DISPLAY
  • Tank filling and draining
  • Conditioning load-cell and strain-gauge bridge outputs into linear 4-20 mA weighing signals
  • Weighing with a taring function
  • Amplifying pressure or force sensor bridge signals for process monitoring and control
  • Measurement of cable tensile force
  • Level control
  • Signal conversion/amplification

OMEGA DRST-BG Specifications

Series DRST-BG Series
Type DIN rail signal conditioner
Supply voltage DC Supply
Input -40 mV to 100 mV I/P
Configuration Bridge
Input Strain I/P & Process O/P Class
Supply voltage 19.2...28.8 V DC
Internal consumption 2.2 W
Maximum consumption 7.2 W
Transducer supply 5...13 V DC
Transducer supply load (maximum) 230 mA
Measurement range (mV input) -40...100 mV
Minimum measurement range (span) 10 mV
Input resistance > 10 MΩ
Current output signal range 0...20 mA
Voltage output signal range 0...10 V DC
Signal / noise ratio Minimum 60 dB
Signal dynamics, input / output 17 bit / 16 bit
Updating time 20 ms
Response time, programmable 0.06...999 s
Temperature coefficient < ±0.01% of span / °C
Linearity error ≤ ±0.1% of span
Effect of supply voltage change < ±0.002% of span / %V
EMC immunity influence < ±0.5% of span
Protection degree IP50
Specifications range -4 to 140°F (-20 to 60°C)
Calibration temperature 68 to 82°F (20 to 28°C)
Relative air humidity < 95% RH (non-condensing)
Product Type mV to current/voltage transmitter / load cell amplifier
Max. Consumption 7.2 W
Signal Dynamics, Input 17 bit
Signal Dynamics, Output 16 bit
mV Measurement Range -40...100 mV
Min. Measurement Range (Span) 10 mV
Max. Offset 70% of selected maximum. value
Input in Relation to Supply Gnd > -5 V and < +10 V
Max. Cable Resistance per Wire 15 Ω
Suppression of Transducer Cable Resistance > 300
Overrange 0...999% of selected measurement range
Taring Input PNP / NPN / Front Key
Digital Input NPN Pull Up 24 VDC / 6.9 mA
Digital Input PNP Pull Down 0 VDC / 6.9 mA
Digital Input Trig Level Low < 6 VDC
Digital Input Trig Level High > 10.5 VDC
Digital Input Pulse Width > 30 ms
Current Output Min. Signal Range (Span) 5 mA
Current Output Max. Offset 50% of selected maximum. value
Current Output Load (maximum.) 20 mA / 600 Ω / 12 VDC
Current Output Load Stability < ±0.01% of span/100 Ω
Current Limit < 23 mA
Voltage Output Min. Signal Range (Span) 250 mVDC
Voltage Output Max. Offset 50% of selected maximum. value
Voltage Output Load (minimum.) 500 kΩ
Voltage Limit < 11.5 VDC
Hardware-Programmable Output Ranges 0...10 mA, 0...20 mA, 0...500 mV, 0...1000 mV, 0...5 V, 0...10 V (JP1/JP2 jumpers)
User Interface 3-digit display and 3 front function keys
Front Error LED Red LED flashes at incorrect output / overrange saturation
Common Mode Frequency Suppression 50 or 60 Hz selectable
Observed Authority Requirements EMC 2004/108/EC EN 61326-1; EAC TR-CU 020/2011 EN 61326-1
Dimensions (H x W x D) 3.17 x 1.40 x 3.33" (80.5 x 35.5 x 84.5 mm)
Weight 4.59 oz (130 g)

What's included with the OMEGA DRST-BG

  • Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output

Click on a category to view a selection of compatible accessories with the Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output.

Omega DRST-CM Series Communication Programmer, snap front mount DRST-CM
This communication programmer is configured for Snap Front Mount, Programming Display for DRST-AC, DRST-DC. It has display of LCD display with 4 lines. It suits drst transmitter configuration and device error detection.




Ask a question about Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output

Customer Reviews for the OMEGA DRST-BG

OMEGA DRST-BG Offers

The DRST-BG converts bipolar mV signals from transducers supplied directly by the module to standard current / voltage signals. The DRST-BG is suitable for load cell applications.

By way of the relative calibration function the scale can be tared, i.e. 0 and 100% calibrated without the need of the equivalent load.

Features

  • Programming, process monitoring and diagnostics via DRSL-DISPLAY
  • Load cell amplifier
  • Mv to current/voltage conversion
  • Front-programmable/led display
  • Relative calibration of input span
  • Npn/pnp input for external taring
  • Supply for standard transducers

Applications

  • Providing local readout of process values via the detachable DRSL-DISPLAY
  • Tank filling and draining
  • Conditioning load-cell and strain-gauge bridge outputs into linear 4-20 mA weighing signals
  • Weighing with a taring function
  • Amplifying pressure or force sensor bridge signals for process monitoring and control
  • Measurement of cable tensile force
  • Level control
  • Signal conversion/amplification

OMEGA DRST-BG Specifications

Series DRST-BG Series
Type DIN rail signal conditioner
Supply voltage DC Supply
Input -40 mV to 100 mV I/P
Configuration Bridge
Input Strain I/P & Process O/P Class
Supply voltage 19.2...28.8 V DC
Internal consumption 2.2 W
Maximum consumption 7.2 W
Transducer supply 5...13 V DC
Transducer supply load (maximum) 230 mA
Measurement range (mV input) -40...100 mV
Minimum measurement range (span) 10 mV
Input resistance > 10 MΩ
Current output signal range 0...20 mA
Voltage output signal range 0...10 V DC
Signal / noise ratio Minimum 60 dB
Signal dynamics, input / output 17 bit / 16 bit
Updating time 20 ms
Response time, programmable 0.06...999 s
Temperature coefficient < ±0.01% of span / °C
Linearity error ≤ ±0.1% of span
Effect of supply voltage change < ±0.002% of span / %V
EMC immunity influence < ±0.5% of span
Protection degree IP50
Specifications range -4 to 140°F (-20 to 60°C)
Calibration temperature 68 to 82°F (20 to 28°C)
Relative air humidity < 95% RH (non-condensing)
Product Type mV to current/voltage transmitter / load cell amplifier
Max. Consumption 7.2 W
Signal Dynamics, Input 17 bit
Signal Dynamics, Output 16 bit
mV Measurement Range -40...100 mV
Min. Measurement Range (Span) 10 mV
Max. Offset 70% of selected maximum. value
Input in Relation to Supply Gnd > -5 V and < +10 V
Max. Cable Resistance per Wire 15 Ω
Suppression of Transducer Cable Resistance > 300
Overrange 0...999% of selected measurement range
Taring Input PNP / NPN / Front Key
Digital Input NPN Pull Up 24 VDC / 6.9 mA
Digital Input PNP Pull Down 0 VDC / 6.9 mA
Digital Input Trig Level Low < 6 VDC
Digital Input Trig Level High > 10.5 VDC
Digital Input Pulse Width > 30 ms
Current Output Min. Signal Range (Span) 5 mA
Current Output Max. Offset 50% of selected maximum. value
Current Output Load (maximum.) 20 mA / 600 Ω / 12 VDC
Current Output Load Stability < ±0.01% of span/100 Ω
Current Limit < 23 mA
Voltage Output Min. Signal Range (Span) 250 mVDC
Voltage Output Max. Offset 50% of selected maximum. value
Voltage Output Load (minimum.) 500 kΩ
Voltage Limit < 11.5 VDC
Hardware-Programmable Output Ranges 0...10 mA, 0...20 mA, 0...500 mV, 0...1000 mV, 0...5 V, 0...10 V (JP1/JP2 jumpers)
User Interface 3-digit display and 3 front function keys
Front Error LED Red LED flashes at incorrect output / overrange saturation
Common Mode Frequency Suppression 50 or 60 Hz selectable
Observed Authority Requirements EMC 2004/108/EC EN 61326-1; EAC TR-CU 020/2011 EN 61326-1
Dimensions (H x W x D) 3.17 x 1.40 x 3.33" (80.5 x 35.5 x 84.5 mm)
Weight 4.59 oz (130 g)

What's included with the OMEGA DRST-BG

  • Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output

Click on a category to view a selection of compatible accessories with the Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output.

Omega DRST-CM Series Communication Programmer, snap front mount DRST-CM
This communication programmer is configured for Snap Front Mount, Programming Display for DRST-AC, DRST-DC. It has display of LCD display with 4 lines. It suits drst transmitter configuration and device error detection.




Ask a question about Omega DRST-BG DIN Rail Signal Conditioner, bridge/strain input, process output

Customer Reviews for the OMEGA DRST-BG

More OMEGA Products