For load cell and strain gauge measurement and force and weight indication, this strain gauge meter provides consistent performance. It has accuracy of ±0.005% reading.
For load cell and strain gauge measurement and force and weight indication, this strain gauge meter provides consistent performance. It has accuracy of ±0.005% reading.
The OMEGA DP41 Series of digital panel meter/controllers has set the world standard for accuracy and quality in industrial instrumentation. Standard features include 6-digit display; 5 front-panel pushbutton keys; 4 open-collector outputs; and alarm/control, BCD, and analog outputs. On-board excitation allows these meters to power virtually any sensor or transmitter, and 4 setpoints give the user numerous control/alarm possibilities.
Features
Applications
| Series | DP41 Series |
| Type | strain gauge meter |
| Accuracy | ±0.005% reading |
| Span Temperature Coefficient | ±20 ppm |
| Resolution | 15-bit |
| Conversion | Dual-slope technique |
| Reading Rate | 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz |
| Step Response | 1 s to 99.9% |
| Normal-Mode Rejection | 60 dB |
| Common-Mode Rejection | 120 dB |
| Common-Mode Voltage | 1500 Vp per HV test |
| Display | Red or green 6-digit, 14-segment, 0.54" (13.7 mm) high; 4 alarm indicators |
| Sensor Excitation | 10 V at 30 mA; 24 V at 25 mA |
| Setpoint Outputs | 4 isolated open collector; rated 150 mA at 1 V sink, 30 V open |
| Power | 115 or 230 V AC, 49 to 400 Hz; 10 to 32 V DC |
| Power Consumption | 6 W nominal, 10 W maximum |
| Warm-Up to Rated Accuracy | 50 minutes |
| Operating Environment | 32 to 122°F (0 to 50°C); 95% RH, non-condensing |
| Storage Temperature | -40 to 185°F (-40 to 85°C) |
| Panel Cutout | 1.772 x 3.622" (45 x 92 mm) H x W; 1/8 DIN |
| Front Panel Rating | NEMA 4 (IP65) |
| Offset Adjustment | 0 to 999,999 or 0 to -99,999, programmable |
| Span Adjustment | 0.00001 to 500,000, programmable |
| Voltage Input Ranges | 0 to 100 mV, 0 to 1 V, 0 to 5 V, 1 to 5 V, 0 to 10 V, 0 to 100 V, ±50 mV, ±500 mV, ±5 V, ±50 V |
| Current Input Ranges | 0 to 20 mA, 4 to 20 mA |
| Input Configuration | Single-ended |
| Polarity | Unipolar/bipolar, programmable |
| BCD Output | Isolated, tri-state, TTL/CMOS compatible; external 5 V supply required for isolated; internal 5 V supply for non-isolated |
| Dual Relays | Form "C", 7 A @ 30 V DC or 230 V AC |
| 4-Relay Option | Dual 7 A relays and dual 1 A relays |
| Analog Output | 0 to 5 V/1 to 5 V/0 to 10 V/0 to 20 mA/4 to 20 mA, user selectable; 354 Vp isolation; 15-bit resolution; 0.1% accuracy; 50 ms step response |
| Sensor Break Protection | Up-scale or down-scale, programmable |
| RS232 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ11 4-wire connection; programmable to transmit current display, alarm status, minimum/maximum, actual measured input value and status |
| RS485 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ12 6-wire connection; addressable from 0 to 199 |
| Dimensions | 1.89 x 3.78 x 6.5" (48 x 96 x 165 mm) H x W x D |
| Weight | 1.27 lb (574 g) |
| Series | DP41 Series |
| Type | strain gauge meter |
| Accuracy | ±0.005% reading |
| Span Temperature Coefficient | ±20 ppm |
| Resolution | 15-bit |
| Conversion | Dual-slope technique |
| Reading Rate | 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz |
| Step Response | 1 s to 99.9% |
| Normal-Mode Rejection | 60 dB |
| Common-Mode Rejection | 120 dB |
| Common-Mode Voltage | 1500 Vp per HV test |
| Display | Red or green 6-digit, 14-segment, 0.54" (13.7 mm) high; 4 alarm indicators |
| Sensor Excitation | 10 V at 30 mA; 24 V at 25 mA |
| Setpoint Outputs | 4 isolated open collector; rated 150 mA at 1 V sink, 30 V open |
| Power | 115 or 230 V AC, 49 to 400 Hz; 10 to 32 V DC |
| Power Consumption | 6 W nominal, 10 W maximum |
| Warm-Up to Rated Accuracy | 50 minutes |
| Operating Environment | 32 to 122°F (0 to 50°C); 95% RH, non-condensing |
| Storage Temperature | -40 to 185°F (-40 to 85°C) |
| Panel Cutout | 1.772 x 3.622" (45 x 92 mm) H x W; 1/8 DIN |
| Front Panel Rating | NEMA 4 (IP65) |
| Offset Adjustment | 0 to 999,999 or 0 to -99,999, programmable |
| Span Adjustment | 0.00001 to 500,000, programmable |
| Voltage Input Ranges | 0 to 100 mV, 0 to 1 V, 0 to 5 V, 1 to 5 V, 0 to 10 V, 0 to 100 V, ±50 mV, ±500 mV, ±5 V, ±50 V |
| Current Input Ranges | 0 to 20 mA, 4 to 20 mA |
| Input Configuration | Single-ended |
| Polarity | Unipolar/bipolar, programmable |
| BCD Output | Isolated, tri-state, TTL/CMOS compatible; external 5 V supply required for isolated; internal 5 V supply for non-isolated |
| Dual Relays | Form "C", 7 A @ 30 V DC or 230 V AC |
| 4-Relay Option | Dual 7 A relays and dual 1 A relays |
| Analog Output | 0 to 5 V/1 to 5 V/0 to 10 V/0 to 20 mA/4 to 20 mA, user selectable; 354 Vp isolation; 15-bit resolution; 0.1% accuracy; 50 ms step response |
| Sensor Break Protection | Up-scale or down-scale, programmable |
| RS232 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ11 4-wire connection; programmable to transmit current display, alarm status, minimum/maximum, actual measured input value and status |
| RS485 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ12 6-wire connection; addressable from 0 to 199 |
| Dimensions | 1.89 x 3.78 x 6.5" (48 x 96 x 165 mm) H x W x D |
| Weight | 1.27 lb (574 g) |