Built for process voltage and current monitoring, this panel meter is supplied with 1/8 DIN, 6 Digit, 14-Segment LED Display. It has accuracy of ±0.005% rdg. It also suits thermocouple and rtd temperature indication.
Built for process voltage and current monitoring, this panel meter is supplied with 1/8 DIN, 6 Digit, 14-Segment LED Display. It has accuracy of ±0.005% rdg. It also suits thermocouple and rtd temperature indication.
The OMEGA DP41 Series of digital panel meter/controllers has set the world standard for accuracy and quality in industrial instrumentation. These meters can measure a broad spectrum of DC voltage and current ranges as well as inputs from 9 thermocouple types and from most RTDs, pressure transducers, load cells, strain gauges, and mechanical potentiometers. The DP41 displays feature 14-segment LED characters, which greatly improves alphanumeric representations.
Features
Applications
| Series | DP41 Series |
| Type | panel meter |
| Panel size | 1/8 DIN |
| Display | 6 Digit |
| Configuration | 14-Segment LED Display |
| Supply voltage | AC Supply |
| Input | Analog Current/Voltage I/P |
| Accuracy | ±0.005% rdg |
| Span Temperature Coefficient | ±20 ppm |
| Step Response | 1 s to 99.9% |
| Warm-Up to Rated Accuracy | 50 minutes |
| Operating Environment | 32 to 122°F (0 to 50°C); 95% RH, non-condensing |
| Storage Temperature | -40 to 185°F (-40 to 85°C) |
| Power | 115 or 230 V AC, 49 to 400 Hz; 10 to 32 V DC |
| Power Consumption | 6 W nominal, 10 W maximum |
| Normal-Mode Rejection | 60 dB |
| Common-Mode Rejection | 120 dB |
| Common-Mode Voltage | 1500 Vp per HV test |
| Resolution | 15-bit |
| Conversion | Dual-slope technique |
| Reading Rate | 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz |
| Display | Red or green 6-digit, 14-segment, 0.54" (13.7 mm) high; 4 alarm indicators |
| Panel Cutout | 1.772 x 3.622" (45 x 92 mm); 1/8 DIN |
| Voltage Input Ranges | 0 to 100 mV, 0 to 1 V, 0 to 5 V, 1 to 5 V, 0 to 10 V, 0 to 100 V, ±50 mV, ±500 mV, ±5 V, ±50 V |
| Current Input Ranges | 0 to 20 mA, 4 to 20 mA |
| Input Configuration | Single-ended |
| Polarity | Unipolar/bipolar, programmable |
| Span Adjustment | 0.00001 to 500,000, programmable |
| Setpoint Outputs | 4 isolated open collector; rated 150 mA at 1 V sink, 30 V open |
| Offset Adjustment | 0 to 999,999 or 0 to -99,999, programmable |
| Thermocouple Input Types | J, K, T, E, R, S, B, N, J DIN |
| RTD Input | Any 6 Ω to 6 kΩ NIST or DIN platinum and any linear RTD |
| RTD Connection | 2-, 3- or 4-wire |
| Thermocouple Accuracy | 3.6°F (0.2°C) for most thermocouple types |
| Sensor Break Protection | Up-scale or down-scale, programmable |
| Sensor Excitation | 10 V at 30 mA; 24 V at 25 mA |
| BCD Output | Isolated, tri-state, TTL/CMOS compatible; external 5 V supply required for isolated; internal 5 V supply for non-isolated |
| Dual Relays | Form "C", 7 A @ 30 V DC or 230 V AC |
| 4-Relay Option | Dual 7 A relays and dual 1 A relays |
| Analog Output | 0 to 5 V/1 to 5 V/0 to 10 V/0 to 20 mA/4 to 20 mA, user selectable; 354 Vp isolation; 15-bit resolution; 0.1% accuracy; 50 ms step response |
| RS232 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ11 4-wire connection; programmable to transmit current display, alarm status, minimum/maximum, actual measured input value and status |
| RS485 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ12 6-wire connection; addressable from 0 to 199 |
| Thermocouple Range, Iron-constantan (J) | -346 to 1400°F (-210 to 760°C) / -346 to 1400°F, 0.2°C/0.3°F |
| Thermocouple Range, CHROMEGA-ALOMEGA (K) | -454 to 2502°F (-270 to 1372°C) / -454 to 2500°F, 0.2°C/0.3°F |
| Thermocouple Range, Copper-constantan (T) | -454 to 752°F (-270 to 400°C) / -454 to 752°F, 0.2°C/0.3°F |
| Thermocouple Range, CHROMEGA-constantan (E) | -454 to 1832°F (-270 to 1000°C) / -454 to 1832°F, 0.2°C/0.3°F |
| Thermocouple Range, Pt/Rh (R, S) | -58 to 3214°F (-50 to 1768°C) / -58 to 3214°F, 0.2°C/0.3F |
| Thermocouple Range, Pt/30% Rh-Pt/6° Rh (B) | 212 to 3308°F (100 to 1820°C) / 212 to 3300°F, 0.3°C/0.5F |
| Thermocouple Range, OMEGALLOY (N) | -454 to 2372°F (-270 to 1300°C) / -454 to 2372°F, 0.2°C/0.3F |
| Thermocouple Range, Iron-constantan (J DIN) | -328 to 1652°F (-200 to 900°C) / -328 to 1652°F, 0.6°C/1.0F |
| Thermocouple Range, All curves | -328 to 1562°F (-200 to 850°C) / -328 to 1562°F, 0.2°C/0.3F |
| RTD Range, RTD 1 (10 Ω copper) | -328 to 392°F (-200 to 200°C) / -328 to 392°F / 73.2 to 473.2 K, 1.0°C/2.0°F/1.0 K |
| RTD Range, RTD 2 (100 Ω Pt 0.00385) | 392 to 1652°F (200 to 900°C) / -328 to 1652°F / 73.2 to 1173.2 K, 0.2°C/0.3°F/0.2 K |
| RTD Range, RTD 3 (100 Ω Pt 0.00392) | -328 to 1562°F (-200 to 850°C) / -328 to 1562°F / 73.2 to 1123.2 K, 0.2°C/0.3°F/0.2 K |
| Dimensions | 1.89 x 3.78 x 6.5" (48 x 96 x 165 mm) |
| Weight | 1.27 lb (574 g) |
| Series | DP41 Series |
| Type | panel meter |
| Panel size | 1/8 DIN |
| Display | 6 Digit |
| Configuration | 14-Segment LED Display |
| Supply voltage | AC Supply |
| Input | Analog Current/Voltage I/P |
| Accuracy | ±0.005% rdg |
| Span Temperature Coefficient | ±20 ppm |
| Step Response | 1 s to 99.9% |
| Warm-Up to Rated Accuracy | 50 minutes |
| Operating Environment | 32 to 122°F (0 to 50°C); 95% RH, non-condensing |
| Storage Temperature | -40 to 185°F (-40 to 85°C) |
| Power | 115 or 230 V AC, 49 to 400 Hz; 10 to 32 V DC |
| Power Consumption | 6 W nominal, 10 W maximum |
| Normal-Mode Rejection | 60 dB |
| Common-Mode Rejection | 120 dB |
| Common-Mode Voltage | 1500 Vp per HV test |
| Resolution | 15-bit |
| Conversion | Dual-slope technique |
| Reading Rate | 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz |
| Display | Red or green 6-digit, 14-segment, 0.54" (13.7 mm) high; 4 alarm indicators |
| Panel Cutout | 1.772 x 3.622" (45 x 92 mm); 1/8 DIN |
| Voltage Input Ranges | 0 to 100 mV, 0 to 1 V, 0 to 5 V, 1 to 5 V, 0 to 10 V, 0 to 100 V, ±50 mV, ±500 mV, ±5 V, ±50 V |
| Current Input Ranges | 0 to 20 mA, 4 to 20 mA |
| Input Configuration | Single-ended |
| Polarity | Unipolar/bipolar, programmable |
| Span Adjustment | 0.00001 to 500,000, programmable |
| Setpoint Outputs | 4 isolated open collector; rated 150 mA at 1 V sink, 30 V open |
| Offset Adjustment | 0 to 999,999 or 0 to -99,999, programmable |
| Thermocouple Input Types | J, K, T, E, R, S, B, N, J DIN |
| RTD Input | Any 6 Ω to 6 kΩ NIST or DIN platinum and any linear RTD |
| RTD Connection | 2-, 3- or 4-wire |
| Thermocouple Accuracy | 3.6°F (0.2°C) for most thermocouple types |
| Sensor Break Protection | Up-scale or down-scale, programmable |
| Sensor Excitation | 10 V at 30 mA; 24 V at 25 mA |
| BCD Output | Isolated, tri-state, TTL/CMOS compatible; external 5 V supply required for isolated; internal 5 V supply for non-isolated |
| Dual Relays | Form "C", 7 A @ 30 V DC or 230 V AC |
| 4-Relay Option | Dual 7 A relays and dual 1 A relays |
| Analog Output | 0 to 5 V/1 to 5 V/0 to 10 V/0 to 20 mA/4 to 20 mA, user selectable; 354 Vp isolation; 15-bit resolution; 0.1% accuracy; 50 ms step response |
| RS232 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ11 4-wire connection; programmable to transmit current display, alarm status, minimum/maximum, actual measured input value and status |
| RS485 Communications | 300/600/1200/2400/4800/9600/19.2K baud; RJ12 6-wire connection; addressable from 0 to 199 |
| Thermocouple Range, Iron-constantan (J) | -346 to 1400°F (-210 to 760°C) / -346 to 1400°F, 0.2°C/0.3°F |
| Thermocouple Range, CHROMEGA-ALOMEGA (K) | -454 to 2502°F (-270 to 1372°C) / -454 to 2500°F, 0.2°C/0.3°F |
| Thermocouple Range, Copper-constantan (T) | -454 to 752°F (-270 to 400°C) / -454 to 752°F, 0.2°C/0.3°F |
| Thermocouple Range, CHROMEGA-constantan (E) | -454 to 1832°F (-270 to 1000°C) / -454 to 1832°F, 0.2°C/0.3°F |
| Thermocouple Range, Pt/Rh (R, S) | -58 to 3214°F (-50 to 1768°C) / -58 to 3214°F, 0.2°C/0.3F |
| Thermocouple Range, Pt/30% Rh-Pt/6° Rh (B) | 212 to 3308°F (100 to 1820°C) / 212 to 3300°F, 0.3°C/0.5F |
| Thermocouple Range, OMEGALLOY (N) | -454 to 2372°F (-270 to 1300°C) / -454 to 2372°F, 0.2°C/0.3F |
| Thermocouple Range, Iron-constantan (J DIN) | -328 to 1652°F (-200 to 900°C) / -328 to 1652°F, 0.6°C/1.0F |
| Thermocouple Range, All curves | -328 to 1562°F (-200 to 850°C) / -328 to 1562°F, 0.2°C/0.3F |
| RTD Range, RTD 1 (10 Ω copper) | -328 to 392°F (-200 to 200°C) / -328 to 392°F / 73.2 to 473.2 K, 1.0°C/2.0°F/1.0 K |
| RTD Range, RTD 2 (100 Ω Pt 0.00385) | 392 to 1652°F (200 to 900°C) / -328 to 1652°F / 73.2 to 1173.2 K, 0.2°C/0.3°F/0.2 K |
| RTD Range, RTD 3 (100 Ω Pt 0.00392) | -328 to 1562°F (-200 to 850°C) / -328 to 1562°F / 73.2 to 1123.2 K, 0.2°C/0.3°F/0.2 K |
| Dimensions | 1.89 x 3.78 x 6.5" (48 x 96 x 165 mm) |
| Weight | 1.27 lb (574 g) |