Omega DP400S Strain Gauge Meter, 2 relay & analog output, AC/DC supply

Model: DP400S

Omega DP400S Strain Gauge Meter, 2 relay & analog output, AC/DC supply

Model: DP400S

This strain gauge meter is configured for 1/8 DIN, Backlight Graphic OLED Display, AC/DC Supply. It has display of Backlighting graphic OLED 2.42" (6.1 cm) (DP400S). It suits load cell measurement and melt pressure sensor monitoring.

This strain gauge meter is configured for 1/8 DIN, Backlight Graphic OLED Display, AC/DC Supply. It has display of Backlighting graphic OLED 2.42" (6.1 cm) (DP400S). It suits load cell measurement and melt pressure sensor monitoring.

Your Price $678.03 USD
Availability 2 to 3 Weeks
Quantity

OMEGA DP400S Offers

DP400S is an indicator/panel meter for acquisition and retransmission of processes, also with fast transient. It is provided with relay outputs for alarm purpose, analog output for retransmission of process/setpoints and programmable digital inputs.

DP400S is an indicator/panel meter for acquisition and retransmission of processes, also with fast transient. It is provided with relay outputs for alarm purpose, analog output for retransmission of process/setpoints and programmable digital inputs. Available in standard format 3.78 x 1.89" (96 x 48 mm), the device can be configured both for horizontal and vertical mounting.

Available in standard format 3.78 x 1.89 in (96 x 48 mm), the device can be configured both for horizontal and vertical mounting. Distinctive feature is the intuitive multilingual interface, supported by a graphic OLED monochromatic yellow display 128 x 64 pixel.

Distinctive feature is the intuitive multilingual interface, supported by a graphic OLED monochromatic yellow display 128 x 64 pixel. Serial connectivity relies on RS485 and Modbus-RTU protocol.

Visualization options include bar graph and process trend with programmable sampling time. Software features include mathematical functions related to process value like totalizer and sum. Serial connectivity relies on RS485 and Modbus-RTU protocol.

Features

  • Indicator/panel meter for acquisition and retransmission of processes, also with fast transient
  • Provided with relay outputs for alarm purpose, analog output for retransmission of process/setpoints and programmable digital inputs
  • Available in standard format 3.78 x 1.89" (96 x 48 mm), configurable both for horizontal and vertical mounting
  • Intuitive multilingual interface, supported by a graphic oled monochromatic yellow display 128 x 64 pixel
  • Visualization options include bar graph and process trend with programmable sampling time
  • Software features include mathematical functions related to process value like totalizer and sum
  • Serial connectivity relies on rs485 and modbus-rtu protocol
  • Quick device setup by direct link app (only for android) on smartphones provided with nfc
  • Differential input, software-configurable for strain-gauge (load cells or melt sensors) or potentiometer
  • Basic data logger function storing process data on eeprom

Applications

  • Acquiring and displaying load-cell weight in industrial weighing systems
  • Load cell measurement
  • Monitoring strain-gauge force and pressure signals on a control panel
  • Weighing systems
  • Reading Dynisco Melt pressure sensors on plastic extrusion lines
  • Melt pressure sensor monitoring
  • Totalizing flow rate to track total volume since last reset
  • Force and strain measurement
  • Retransmitting process values to a PLC via RS485 Modbus-RTU
  • Industrial process retransmission

OMEGA DP400S Specifications

Display Backlighting graphic OLED 2.42"
Series DP400S Series
Operating temperature 32°F to 104°F (0°C to 40°C)
Type strain gauge meter
Humidity 35 to 95 Rh%
Panel size 1/8 DIN
Sealing IP54 front panel (with gasket), IP20 box and terminals
Configuration Backlight Graphic OLED Display
Material Box: Polycarbonate V0
Supply voltage AC/DC Supply
Power supply 24 to 230 Vac/Vdc ±15% 50/60 Hz
Output type 2 Relay & Analog O/P
Consumption 8 VA
Configuration Isolated RS485 Communication
Analog input Differential input (IN+ / IN-), software-configurable - for strain-gauge (load cells or Melt sensors), max 7.5 mV/V with 5 V power supply (max 4 cells 350 Ω in parallel); for potentiometer (min. 200 Ω), 5 V power supply
Configuration RFID/NFC Enabled
Tolerance (25°C) ±0.2% ±1 digit (f.s.)
Display Backlighting graphic OLED 2.42" (6.1 cm) (DP400S)
Impedance Ri > 1 MΩ
Power Supply Range 24 to 230 V AC/V DC ±15% 50/60 Hz, Consumption: 8 VA
Relay outputs 2 Relays Contacts 2 A - 250 Vac, resistive charge
Analog Input Differential input, software-configurable, for strain-gauge (load cells or Melt sensors), maximum 7.5 mV/V with 5 V power supply (maximum 4 cells 350 Ω in parallel); for potentiometer (minimum. 200 Ω, 5 V power supply)
Electrical endurance Q1 / Q2 2 A, 250 Vac, resistive load, 10^5 operations; 20/2 A, 250 Vac, cosφ = 0.3, 10^5 operations
Analog Input Impedance Ri >1 MΩ
Analog output Configurable as 0..20 mA or 4..20 mA, resolution 16 bit, ±0.2% (f.s.)
Relay Outputs 2 Relays, Contacts 2 A - 250 V AC, Resistive charge
Supply wiring Must be ≥18 AWG with cables suitable for temperatures > 158°F (> 70°C)
Analog Output Configurable as 0 to 20 mA or 4 to 20 mA, Resolution 16 bit ±0.2% (F.s.)
Serial communication RS485, Modbus-RTU protocol
Serial Communication RS485, Modbus-RTU protocol
Dimensions 3.78" (96 mm) x 1.89" (48 mm)
Front panel cut-out: 1.77" x 3.58" (45 x 91 mm)
Suggested panel thickness: 0.08" to 0.59" (2 to 15 mm)
Material Box: Polycarbonate V0
Weight Approx. 0.36 lb (165 g)
Tolerance (25°C) ±0.2% ±1 digit (f.s.)
Front Panel Cut-Out 1.77 x 3.58" (45 x 91 mm)
Sealing IP54 front panel (with gasket) - IP20 box and terminals
Operating Temperature 32 to 104°F (0 to 40°C)
Humidity 35 to 95 Rh%
mV/V Sensor 0,001 to 20,000 mV/V, Default: 2,000 mV/V
Relay Electrical Endurance (Q1/Q2) 2 A, 250 V AC, resistive load, 105 operations; 20/2 A, 250 V AC, cosφ = 0.3, 105 operations
Digital Inputs 2 PNP digital inputs, +12 V DC (configurable by parameters 95 and 100)
Baud Rate 1.200 / 2.400 / 4.800 / 9.600 / 19.200 / 28.800 / 38.400 / 57.600 / 115.200 baud (Default 57.600)
Serial Format 8,N,1 (Default); 8,E,1; 8,O,1; 8,N,2; 8,E,2; 8,O,2
Supported Modbus Functions Word reading maximum 20 word (0x03, 0x04); single word writing (0x06); multiple words writing maximum 20 word (0x10)
Sampling Frequency 1200 Hz (0.83ms, maximum speed) to 1.18 Hz (851ms, minimum speed); Default 12.5 Hz (80ms)
Conversion Filter ADC digital filter: Filter 4th ord. / No filter / Average 2 to 20 samp.; Default Average 10 samp.
Alarms ON/OFF with hysteresis; Absolute/Threshold, Band with instantaneous/delayed/retentive action; activation by digital input, sensor failure, serial line, net weight, gross weight, stable weight, sum
Data Logger Selectable time basis 1s to 3600s, total memory 1K samplings; stored on EEPROM
Trend Visualization Up to 59 samples, with selectable time basis 0,1 s to 3600 s
Text Menus English/Italian/Deutsch/French/Spanish
Format 3.78 x 1.89" (96 x 48 mm), configurable for horizontal or vertical mounting
Suggested Panel Thickness 2÷0.59" (15 mm)
Wiring Supply wiring must be ≥18 AWG with cables suitable for temperatures > 70° C
EEPROM Write Cycles 100000 writing cycles
Weight Approx. 5.8 oz (165 g)

What's included with the OMEGA DP400S

  • Omega DP400S Strain Gauge Meter, 2 relay & analog output, AC/DC supply

Ask a question about Omega DP400S Strain Gauge Meter, 2 relay & analog output, AC/DC supply

Customer Reviews for the OMEGA DP400S

OMEGA DP400S Offers

DP400S is an indicator/panel meter for acquisition and retransmission of processes, also with fast transient. It is provided with relay outputs for alarm purpose, analog output for retransmission of process/setpoints and programmable digital inputs.

DP400S is an indicator/panel meter for acquisition and retransmission of processes, also with fast transient. It is provided with relay outputs for alarm purpose, analog output for retransmission of process/setpoints and programmable digital inputs. Available in standard format 3.78 x 1.89" (96 x 48 mm), the device can be configured both for horizontal and vertical mounting.

Available in standard format 3.78 x 1.89 in (96 x 48 mm), the device can be configured both for horizontal and vertical mounting. Distinctive feature is the intuitive multilingual interface, supported by a graphic OLED monochromatic yellow display 128 x 64 pixel.

Distinctive feature is the intuitive multilingual interface, supported by a graphic OLED monochromatic yellow display 128 x 64 pixel. Serial connectivity relies on RS485 and Modbus-RTU protocol.

Visualization options include bar graph and process trend with programmable sampling time. Software features include mathematical functions related to process value like totalizer and sum. Serial connectivity relies on RS485 and Modbus-RTU protocol.

Features

  • Indicator/panel meter for acquisition and retransmission of processes, also with fast transient
  • Provided with relay outputs for alarm purpose, analog output for retransmission of process/setpoints and programmable digital inputs
  • Available in standard format 3.78 x 1.89" (96 x 48 mm), configurable both for horizontal and vertical mounting
  • Intuitive multilingual interface, supported by a graphic oled monochromatic yellow display 128 x 64 pixel
  • Visualization options include bar graph and process trend with programmable sampling time
  • Software features include mathematical functions related to process value like totalizer and sum
  • Serial connectivity relies on rs485 and modbus-rtu protocol
  • Quick device setup by direct link app (only for android) on smartphones provided with nfc
  • Differential input, software-configurable for strain-gauge (load cells or melt sensors) or potentiometer
  • Basic data logger function storing process data on eeprom

Applications

  • Acquiring and displaying load-cell weight in industrial weighing systems
  • Load cell measurement
  • Monitoring strain-gauge force and pressure signals on a control panel
  • Weighing systems
  • Reading Dynisco Melt pressure sensors on plastic extrusion lines
  • Melt pressure sensor monitoring
  • Totalizing flow rate to track total volume since last reset
  • Force and strain measurement
  • Retransmitting process values to a PLC via RS485 Modbus-RTU
  • Industrial process retransmission

OMEGA DP400S Specifications

Display Backlighting graphic OLED 2.42"
Series DP400S Series
Operating temperature 32°F to 104°F (0°C to 40°C)
Type strain gauge meter
Humidity 35 to 95 Rh%
Panel size 1/8 DIN
Sealing IP54 front panel (with gasket), IP20 box and terminals
Configuration Backlight Graphic OLED Display
Material Box: Polycarbonate V0
Supply voltage AC/DC Supply
Power supply 24 to 230 Vac/Vdc ±15% 50/60 Hz
Output type 2 Relay & Analog O/P
Consumption 8 VA
Configuration Isolated RS485 Communication
Analog input Differential input (IN+ / IN-), software-configurable - for strain-gauge (load cells or Melt sensors), max 7.5 mV/V with 5 V power supply (max 4 cells 350 Ω in parallel); for potentiometer (min. 200 Ω), 5 V power supply
Configuration RFID/NFC Enabled
Tolerance (25°C) ±0.2% ±1 digit (f.s.)
Display Backlighting graphic OLED 2.42" (6.1 cm) (DP400S)
Impedance Ri > 1 MΩ
Power Supply Range 24 to 230 V AC/V DC ±15% 50/60 Hz, Consumption: 8 VA
Relay outputs 2 Relays Contacts 2 A - 250 Vac, resistive charge
Analog Input Differential input, software-configurable, for strain-gauge (load cells or Melt sensors), maximum 7.5 mV/V with 5 V power supply (maximum 4 cells 350 Ω in parallel); for potentiometer (minimum. 200 Ω, 5 V power supply)
Electrical endurance Q1 / Q2 2 A, 250 Vac, resistive load, 10^5 operations; 20/2 A, 250 Vac, cosφ = 0.3, 10^5 operations
Analog Input Impedance Ri >1 MΩ
Analog output Configurable as 0..20 mA or 4..20 mA, resolution 16 bit, ±0.2% (f.s.)
Relay Outputs 2 Relays, Contacts 2 A - 250 V AC, Resistive charge
Supply wiring Must be ≥18 AWG with cables suitable for temperatures > 158°F (> 70°C)
Analog Output Configurable as 0 to 20 mA or 4 to 20 mA, Resolution 16 bit ±0.2% (F.s.)
Serial communication RS485, Modbus-RTU protocol
Serial Communication RS485, Modbus-RTU protocol
Dimensions 3.78" (96 mm) x 1.89" (48 mm)
Front panel cut-out: 1.77" x 3.58" (45 x 91 mm)
Suggested panel thickness: 0.08" to 0.59" (2 to 15 mm)
Material Box: Polycarbonate V0
Weight Approx. 0.36 lb (165 g)
Tolerance (25°C) ±0.2% ±1 digit (f.s.)
Front Panel Cut-Out 1.77 x 3.58" (45 x 91 mm)
Sealing IP54 front panel (with gasket) - IP20 box and terminals
Operating Temperature 32 to 104°F (0 to 40°C)
Humidity 35 to 95 Rh%
mV/V Sensor 0,001 to 20,000 mV/V, Default: 2,000 mV/V
Relay Electrical Endurance (Q1/Q2) 2 A, 250 V AC, resistive load, 105 operations; 20/2 A, 250 V AC, cosφ = 0.3, 105 operations
Digital Inputs 2 PNP digital inputs, +12 V DC (configurable by parameters 95 and 100)
Baud Rate 1.200 / 2.400 / 4.800 / 9.600 / 19.200 / 28.800 / 38.400 / 57.600 / 115.200 baud (Default 57.600)
Serial Format 8,N,1 (Default); 8,E,1; 8,O,1; 8,N,2; 8,E,2; 8,O,2
Supported Modbus Functions Word reading maximum 20 word (0x03, 0x04); single word writing (0x06); multiple words writing maximum 20 word (0x10)
Sampling Frequency 1200 Hz (0.83ms, maximum speed) to 1.18 Hz (851ms, minimum speed); Default 12.5 Hz (80ms)
Conversion Filter ADC digital filter: Filter 4th ord. / No filter / Average 2 to 20 samp.; Default Average 10 samp.
Alarms ON/OFF with hysteresis; Absolute/Threshold, Band with instantaneous/delayed/retentive action; activation by digital input, sensor failure, serial line, net weight, gross weight, stable weight, sum
Data Logger Selectable time basis 1s to 3600s, total memory 1K samplings; stored on EEPROM
Trend Visualization Up to 59 samples, with selectable time basis 0,1 s to 3600 s
Text Menus English/Italian/Deutsch/French/Spanish
Format 3.78 x 1.89" (96 x 48 mm), configurable for horizontal or vertical mounting
Suggested Panel Thickness 2÷0.59" (15 mm)
Wiring Supply wiring must be ≥18 AWG with cables suitable for temperatures > 70° C
EEPROM Write Cycles 100000 writing cycles
Weight Approx. 5.8 oz (165 g)

What's included with the OMEGA DP400S

  • Omega DP400S Strain Gauge Meter, 2 relay & analog output, AC/DC supply

Ask a question about Omega DP400S Strain Gauge Meter, 2 relay & analog output, AC/DC supply

Customer Reviews for the OMEGA DP400S

More OMEGA Products