Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC

Model: CNI8DH33

Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC-

Image is for reference only, refer to product info for complete details.

Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC

Model: CNI8DH33

This pid controller is configured for Process & Strain PID Controller, 4 I/P's, 2 O/P. It has universal temperature and process input accuracy of ±0.5°C temperature; 0.03% reading. It suits single-loop temperature control with thermocouple or rtd sensors and strain and load cell measurement with amplified transducers.

This pid controller is configured for Process & Strain PID Controller, 4 I/P's, 2 O/P. It has universal temperature and process input accuracy of ±0.5°C temperature; 0.03% reading. It suits single-loop temperature control with thermocouple or rtd sensors and strain and load cell measurement with amplified transducers.

Your Price $617.54 USD
Availability 2 to 3 Weeks
Quantity

OMEGA CNI8DH33 Offers

The OMEGA CNi8DH and CNi8DV are high-quality, highly accurate single loop autotune PID temperature and process controllers for 1/8 DIN 3.62 x 1.77" (92 x 45 mm) horizontal or vertical panel cutouts. Both devices feature the same state-of-the-art technology, uncompromising accuracy, and quality backed by an extended 5-year warranty.

Features

  • Embedded ethernet connectivity (optional)
  • Dual display with bright color-changing feature
  • Programmable digital filter
  • 2 control or alarm outputs (choice of DC pulse, solid state relays, mechanical relays, analog voltage and current)
  • Full autotune pid control
  • Built-in excitation
  • Front removable

Applications

  • Single-loop temperature control with thermocouple or RTD sensors
  • Process control using voltage or current transmitter inputs
  • Strain and load cell measurement with amplified transducers
  • Alarm monitoring of process or temperature setpoints
  • Networked monitoring and control via ethernet or serial communications

OMEGA CNI8DH33 Specifications

Series CNi8D Series
Type pid controller
Configuration Process & Strain PID Controller
Input 4 I/P's
Output type 2 O/P
Supply voltage 90 V AC to 240 V AC
Configuration CNi8D
Universal Temperature and Process Input Accuracy ±0.5°C temperature; 0.03% reading
Resolution 1°/0.1°; 10 μV process
Input Types Thermocouple, RTD, analog voltage, analog current
Thermocouple Lead Resistance 100 Ω maximum
Thermocouple Types (ITS 90) J, K, T, E, R, S, B, C, N, L (J DIN)
RTD Input (ITS 68) 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve
Voltage Input 0 to 100 mV, 0 to 1 V, 0 to 10 V DC
Current Input 0 to 20 mA (5 Ω load)
Reading Rate 3 samples/s
Control Action Reverse (heat) or direct (cool)
Excitation (Optional In Place Of Communication) 5 V DC @ 40 mA; 10 V DC @ 60 mA
Power 90 to 240 V AC ±10%, 50 to 400 Hz, 110 to 300 V DC equivalent voltage
Low Voltage Power Option 24 V AC, 12 to 36 V DC for DPi/CNi/DPiS/CNiS; 20 to 36 V DC for dual display, ethernet and isolated analog output from qualified safety approved source
Connection Screw terminals
Environmental Conditions, Dual Display Models 32 to 122°F (0 to 50°C), 90% RH non-condensing (for UL only)
Approvals UL, C-UL, CE per 2014/35/EU, FM (temperature units only)
Panel Cutout, i/8 Series 1.772 x 3.622" (45 x 92 mm), 1/8 DIN
Temperature Stability, RTD 0.04°C/°C
Temperature Stability, TC @ 25°C (77°F) 0.05°C/°C
Cold Junction Compensation 50 ppm/°C or 0.001
NMRR 60 dB
CMRR 120 dB
A/D Conversion Dual slope
Digital Filter Programmable
Display 4-digit 9-segment LED 0.40" (10.2 mm); i32, i16, i16D, i8DV 0.83" (21 mm); i8 ... RED, GREEN, AMBER programmable colors for process variable, setpoint and temperature units
Input Impedance 10 MΩ for 100 mV; 1 MΩ for 1 or 10 V DC
Linearization Points Up to 10
Polarity Unipolar
Step Response 0.7 sec for 99.9%
Universal Strain and Process Input (DPiS/CNiS Models) Accuracy 0.03% reading
Strain/Process Resolution 10/1μV
Strain/Process Temperature Stability 50 ppm/°C
Strain/Process Voltage Input 0 to 100 mVdc, -100 mVdc to 1 V DC, 0 to 10 V DC
Strain/Process Current Input 0 to 20 mA (5 Ω load)
Strain/Process Excitation (Not Included with Communication) 24 V DC @ 25 mA (not available for low-power option)
Control Modes Time and amplitude proportional control; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative and anti-reset Windup, and on/off
Rate 0 to 399.9 s
Reset 0 to 3999 s
Cycle Time 1 to 199 s; set to 0 for on/off
Gain 0.5 to 100% of span
Control Output Relay 250 V AC or 30 V DC @ 3 A (resistive load); configurable for on/off, PID and ramp and soak
Control Output SSR 20 to 265 V AC @ 0.05 to 0.5 A (resistive load); continuous
Control Output DC Pulse Non-isolated; 10 V DC @ 20 mA
Analog Output (Output 1 Only) Non-isolated, proportional 0 to 10 V DC or 0 to 20 mA; 500 Ω maximum
Output 3 Retransmission Isolated Analog Voltage and Current; Current: 10 V maximum @ 20 mA output; Voltage: 20 mA maximum for 0 to 10 V output
Alarm 1 and 2 (Programmable) Type Same as output 1 and 2
Alarm Operation High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
Isolation, Power to Input/Output 2300 V AC per 1 minute test
Isolation, For Low Voltage Power Option 1500 V AC per 1 minute test
Isolation, Power to Relay/SSR Output 2300 V AC per 1 minute test
Isolation, Relay/SSR to Relay/SSR Output 2300 V AC per 1 minute test
Isolation, RS232/485 to Input/Output 500 V AC per 1 minute test
Environmental Conditions, All Models 32 to 131°F (0 to 55°C) 90% RH non-condensing
Protection, i8/8DH/8DV NEMA 1/Type 1 front bezel
Ethernet Standards compliance IEEE 802.3 10 Base-T; Supported Protocols: TCP/IP, ARP, HTTPGET
RS232/RS422/RS485 Selectable from menu; both ASCII and MODBUS protocol selectable from menu; 300 to 19.2 Kb
RS485 Addressing Addressable from 0 to 199
Dimensions, i/8 Series 1.89 x 3.78 x 5" (48 x 96 x 127 mm) (H x W x D)
Weight, i/8 Series 0.65 lb (295 g)

What's included with the OMEGA CNI8DH33

  • Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC

Ask a question about Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC

Customer Reviews for the OMEGA CNI8DH33

OMEGA CNI8DH33 Offers

The OMEGA CNi8DH and CNi8DV are high-quality, highly accurate single loop autotune PID temperature and process controllers for 1/8 DIN 3.62 x 1.77" (92 x 45 mm) horizontal or vertical panel cutouts. Both devices feature the same state-of-the-art technology, uncompromising accuracy, and quality backed by an extended 5-year warranty.

Features

  • Embedded ethernet connectivity (optional)
  • Dual display with bright color-changing feature
  • Programmable digital filter
  • 2 control or alarm outputs (choice of DC pulse, solid state relays, mechanical relays, analog voltage and current)
  • Full autotune pid control
  • Built-in excitation
  • Front removable

Applications

  • Single-loop temperature control with thermocouple or RTD sensors
  • Process control using voltage or current transmitter inputs
  • Strain and load cell measurement with amplified transducers
  • Alarm monitoring of process or temperature setpoints
  • Networked monitoring and control via ethernet or serial communications

OMEGA CNI8DH33 Specifications

Series CNi8D Series
Type pid controller
Configuration Process & Strain PID Controller
Input 4 I/P's
Output type 2 O/P
Supply voltage 90 V AC to 240 V AC
Configuration CNi8D
Universal Temperature and Process Input Accuracy ±0.5°C temperature; 0.03% reading
Resolution 1°/0.1°; 10 μV process
Input Types Thermocouple, RTD, analog voltage, analog current
Thermocouple Lead Resistance 100 Ω maximum
Thermocouple Types (ITS 90) J, K, T, E, R, S, B, C, N, L (J DIN)
RTD Input (ITS 68) 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve
Voltage Input 0 to 100 mV, 0 to 1 V, 0 to 10 V DC
Current Input 0 to 20 mA (5 Ω load)
Reading Rate 3 samples/s
Control Action Reverse (heat) or direct (cool)
Excitation (Optional In Place Of Communication) 5 V DC @ 40 mA; 10 V DC @ 60 mA
Power 90 to 240 V AC ±10%, 50 to 400 Hz, 110 to 300 V DC equivalent voltage
Low Voltage Power Option 24 V AC, 12 to 36 V DC for DPi/CNi/DPiS/CNiS; 20 to 36 V DC for dual display, ethernet and isolated analog output from qualified safety approved source
Connection Screw terminals
Environmental Conditions, Dual Display Models 32 to 122°F (0 to 50°C), 90% RH non-condensing (for UL only)
Approvals UL, C-UL, CE per 2014/35/EU, FM (temperature units only)
Panel Cutout, i/8 Series 1.772 x 3.622" (45 x 92 mm), 1/8 DIN
Temperature Stability, RTD 0.04°C/°C
Temperature Stability, TC @ 25°C (77°F) 0.05°C/°C
Cold Junction Compensation 50 ppm/°C or 0.001
NMRR 60 dB
CMRR 120 dB
A/D Conversion Dual slope
Digital Filter Programmable
Display 4-digit 9-segment LED 0.40" (10.2 mm); i32, i16, i16D, i8DV 0.83" (21 mm); i8 ... RED, GREEN, AMBER programmable colors for process variable, setpoint and temperature units
Input Impedance 10 MΩ for 100 mV; 1 MΩ for 1 or 10 V DC
Linearization Points Up to 10
Polarity Unipolar
Step Response 0.7 sec for 99.9%
Universal Strain and Process Input (DPiS/CNiS Models) Accuracy 0.03% reading
Strain/Process Resolution 10/1μV
Strain/Process Temperature Stability 50 ppm/°C
Strain/Process Voltage Input 0 to 100 mVdc, -100 mVdc to 1 V DC, 0 to 10 V DC
Strain/Process Current Input 0 to 20 mA (5 Ω load)
Strain/Process Excitation (Not Included with Communication) 24 V DC @ 25 mA (not available for low-power option)
Control Modes Time and amplitude proportional control; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative and anti-reset Windup, and on/off
Rate 0 to 399.9 s
Reset 0 to 3999 s
Cycle Time 1 to 199 s; set to 0 for on/off
Gain 0.5 to 100% of span
Control Output Relay 250 V AC or 30 V DC @ 3 A (resistive load); configurable for on/off, PID and ramp and soak
Control Output SSR 20 to 265 V AC @ 0.05 to 0.5 A (resistive load); continuous
Control Output DC Pulse Non-isolated; 10 V DC @ 20 mA
Analog Output (Output 1 Only) Non-isolated, proportional 0 to 10 V DC or 0 to 20 mA; 500 Ω maximum
Output 3 Retransmission Isolated Analog Voltage and Current; Current: 10 V maximum @ 20 mA output; Voltage: 20 mA maximum for 0 to 10 V output
Alarm 1 and 2 (Programmable) Type Same as output 1 and 2
Alarm Operation High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
Isolation, Power to Input/Output 2300 V AC per 1 minute test
Isolation, For Low Voltage Power Option 1500 V AC per 1 minute test
Isolation, Power to Relay/SSR Output 2300 V AC per 1 minute test
Isolation, Relay/SSR to Relay/SSR Output 2300 V AC per 1 minute test
Isolation, RS232/485 to Input/Output 500 V AC per 1 minute test
Environmental Conditions, All Models 32 to 131°F (0 to 55°C) 90% RH non-condensing
Protection, i8/8DH/8DV NEMA 1/Type 1 front bezel
Ethernet Standards compliance IEEE 802.3 10 Base-T; Supported Protocols: TCP/IP, ARP, HTTPGET
RS232/RS422/RS485 Selectable from menu; both ASCII and MODBUS protocol selectable from menu; 300 to 19.2 Kb
RS485 Addressing Addressable from 0 to 199
Dimensions, i/8 Series 1.89 x 3.78 x 5" (48 x 96 x 127 mm) (H x W x D)
Weight, i/8 Series 0.65 lb (295 g)

What's included with the OMEGA CNI8DH33

  • Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC

Ask a question about Omega CNi8D Series PID Controller, 4 inputs, 90 V AC to 240 V AC