Omega CL940A Industrial Thermocouple Calibrator, K/J/E/T thermocouples, ±0.003% rdg ±5 µV, 500-hour battery

Model: CL940A

Omega CL940A Industrial Thermocouple Calibrator, K/J/E/T thermocouples, ±0.003% rdg ±5 µV, 500-hour battery-

Image is for reference only, refer to product info for complete details.

Omega CL940A Industrial Thermocouple Calibrator, K/J/E/T thermocouples, ±0.003% rdg ±5 µV, 500-hour battery

Model: CL940A

This industrial thermocouple calibrator reads and sources K, J, E, and T thermocouple signals at ±0.003% reading ±5 µV accuracy. It has 0.01° resolution, 500-hour battery life, and meets MIL-PRF-28800F Class 2. It suits field and laboratory thermocouple calibration.

This industrial thermocouple calibrator reads and sources K, J, E, and T thermocouple signals at ±0.003% reading ±5 µV accuracy. It has 0.01° resolution, 500-hour battery life, and meets MIL-PRF-28800F Class 2. It suits field and laboratory thermocouple calibration.

Your Price $1723.71 USD
Availability 2 to 3 Weeks
Quantity

OMEGA CL940A Offers

Industrial handheld thermocouple calibrator that reads and sources thermocouple signals for K, J, E and T types. It offers 500-hour battery life and meets MIL-PRF-28800F Class 2 for field and laboratory use.

These instruments are high performance calibrator-thermometers capable of simulating and measuring a wide-variety of sensors. In addition, features such as high accuracies, preset storage, ramp, step and transfer modes further enhance their versatility.

Features

  • Reads and sources thermocouple signals
  • 0.01°/0.1° display resolution
  • Supports k, j, e and t thermocouples
  • Internal storage for 20 presets
  • 0.01° display resolution
  • 500-hour battery life
  • 500 hour battery life
  • Five (5) digit dual LCD with LED Backlight
  • Meets MIL-prf-28800f class 2
  • Simultaneous Source/Measure
  • Comprehensive real-time statistics: MIN, MAX, AVG, RNG, and STDEV
  • Easy to clean
  • Probe offset function to minimize probe error
  • °F, °C, and mV temperature and voltage units
  • Durable: Meets MIL-PRF-28800F, Class 2 requirements
  • Tilt Stand/Magnet/Hanger

Applications

  • Thermocouple instrument calibration
  • Calibrating thermocouple-based temperature sensors in industrial process loops
  • Field temperature calibration
  • Simulating thermocouple signals to verify temperature transmitters and controllers
  • Thermocouple transmitter calibration
  • Field verification of K, J, E, and T type thermocouple probes
  • Process instrument checking
  • Troubleshooting process readouts using transfer mode to source an offset-corrected mV signal
  • Laboratory calibration
  • Recording temperature stability with real-time MIN/MAX/AVG statistics during calibration

OMEGA CL940A Specifications

Source/measure accuracy ±0.003% [reading] ± 5 µV (18° to 28°C / 64.4° to 82.4°F, CJC error included)
Series CL940A
Resolution 0.01°C up to 999.99°C and 0.1°C at 1000°C or greater
Type thermocouple calibrator
Range -15 mV to 85 mV
Type Industrial handheld thermocouple calibrator
Cold junction error ±0.15°C
Thermocouple types K, J, E, T
Connector type Two (2) Mini-TC Copper
Accuracy ±0.003% reading ±5 μV
Temperature units °C, °F, mV
Resolution 0.01°
Probe zero function Resolution 0.1°C/°F
Battery life 500 hours
Reading rate 3/sec. for readings and TREND indicators
Function Read and source signals
Battery type 3 AA (IEC LR6, ANSI 15) Alkaline
Standard MIL-PRF-28800F Class 2
Battery life 500 hours typical
Range -15 mV to 85 mV
Battery indicator Four (4) stage battery charge indicator
Cold Junction Error ±0.15°C
Display Two (2) rows of five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth
Conformity ITS-90 Types B,E,J,K,N,R,S,T; EN 60584-1 2013 Type C; ASTM E988 Table 3 Type D; ASTM E1751 5.1.1 Type G; DIN 43710 Types L and U; ASTM E1751 5.1.2 Type P
Statistics Minimum reading, Maximum reading, Average reading, Reading range, Standard deviation
Temperature Ranges (CL940A types) K: -382 to 2502°F (-230 to 1372°C) (-382°F to 2502°F); J: -328 to 2192°F (-200 to 1200°C) (-328°F to 2192°F); T: -436 to 752°F (-260 to 400°C) (-436°F to 752°F); E: -400 to 1832°F (-240 to 1000°C) (-400°F to 1832°F)
Display backlight Four (4) LED backlight with 30-second timeout
Connector Type Two (2) Mini-TC Copper
Auto off 20 minute no key pressed Auto Off. Feature can be disabled
Temperature Units °C, °F, mV
Keypad Twelve (12) momentary switches with audible and tactile feedback
Probe Zero Function Resolution 0.1°C/°F
Power cycle configuration retention Instrument retains: Sensor Type, Temperature Unit, Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode
Reading Rate 3/sec. for Readings and TREND indicators
Internal preset storage 20 preset user-determined storage registers, 0-19
Display Two (2) rows of Five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth; 5-DIGIT AUTO-RESOLUTION (0.1/0.01) with backlight and function annunciators
Input current ±50 nA maximum
Display Resolution 0.01° <1000°, .1° ≥ 1000°
Maximum common mode voltage 42 V peak to earth, 1 V p-p between T1 and T2
Display Backlight Four (4) LED Backlight with 30-second timeout
Low resistance load Less than 5 µV change in output with a 100 KΩ resistance
Statistics Minimum Reading, Maximum Reading, Average Reading, Reading Range, Standard Deviation
Operating temp -4° to 131°F (-20° to 55°C)
Auto Off 20 minute no key pressed Auto Off. Feature can be disabled
Storage temp -59.8° to 159.8°F (-51° to 71°C)
Keypad Twelve (12) momentary switches with audible and tactile feedback
Humidity less than 10°C (50°F): Non-condensing
10° to 30°C (50° to 86°F): 5 to 95% RH
30° to 40°C (86° to 104°F): 5 to 85% RH
40° to 55°C (104° to 131°F): 5 to 60% RH
Power Cycle Configuration Retention Retains Sensor Type, Temperature Unit, Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode
Altitude 0 to 15,092 ft (0 to 4600 m)
Internal Preset Storage 20 Preset user-determined storage registers, 0-19
Vibration Random 10-500 Hz, 0.03 g2/Hz
Input Current ±50 nA maximum
Shock 30 g Half Sine
Maximum Common Mode Voltage 42 V peak to earth 1 V p-p between T1 and T2
Drop 4 Drops from 1 m to Concrete
Low Resistance Load Less than 5μV change in output with a 100KΩ resistance
Compliance, electrical CE, MIL-PRF-28800F Class 2
Battery Type 3 AA (IEC LR6, ANSI 15) Alkaline
Compliance, substances RoHS 2 Directive, 2011/65/EU Compliant, REACH
Battery Indicator Four (4) Stage Battery Charge Indicator
Electrical safety IEC-61010
Operating Temp -4 to 131°F (-20 to 55°C)
EMC EN 61326, MIL-PRF-28800F, Class 2
Storage Temp -59.8 to 159.8°F (-51 to 71°C)
ESD IEC 61326 Criterion B
Humidity <50°F (10°C): Non-condensing; 50 to 86°F (10 to 30°C): 5 to 95% RH; 86 to 104°F (30 to 40°C): 5 to 85% RH; 104°F (40°C) to 104 to 131°F (55°C): 5 to 60% RH
Sanitation NSF/ANSI/3-1 14159-2
Altitude 0 to 15,092 ft (0 to 4600 m)
Standards MIL-PRF-28800F, Class 2
Vibration Random 10 – 500 Hz, 0.03 g2/Hz
Included accessories 3 AA Batteries, Quick Start Guide, Tilt Stand/Magnetic, Calibration Report
Shock 30g Half Sine
Conformity ITS-90 Types E, J, K, T
Drop 4 Drops from 3.28' (1 m) to Concrete
Supported thermocouple types K, J, T, E
Compliance, Electrical CE, MIL-PRF-28800F Class 2
Type K range -382° to 2502°F (-230° to 1372°C)
Compliance, Substances RoHS 2 Directive, 2011/65/EU Compliant, REACH
Type J range -328° to 2192°F (-200° to 1200°C)
Electrical Safety IEC-61010
Type T range -436° to 752°F (-260° to 400°C)
EMC EN 61326, MIL-PRF-28800F, Class 2
Type E range -400° to 1832°F (-240° to 1000°C)
ESD IEC 61326 Criterion B
Dimensions 7.6 x 3.3 x 1.1" (193 x 84 x 28 mm)
Sanitation NSF/ANSI/3-1 14159-2
Weight 12.8 oz (362.9 g) including batteries
Included Accessories 3 AA Batteries, Quick Start Guide, Tilt Stand/Magnetic, Calibration Report
Dimensions 7.6 x 3.31 x 1.1" (193 x 84 x 28 mm) (7.6 x 3.3 x 1.1 in)
Weight including Batteries 12.8 oz (362.9 g)

What's included with the OMEGA CL940A

  • Calibrator Thermometer
  • Quick Start Guide
  • Tilt Stand/Magnetic
  • Calibration Report
  • 3 AA Batteries

Ask a question about Omega CL940A Industrial Thermocouple Calibrator, K/J/E/T thermocouples, ±0.003% rdg ±5 µV, 500-hour battery

Customer Reviews for the OMEGA CL940A

OMEGA CL940A Offers

Industrial handheld thermocouple calibrator that reads and sources thermocouple signals for K, J, E and T types. It offers 500-hour battery life and meets MIL-PRF-28800F Class 2 for field and laboratory use.

These instruments are high performance calibrator-thermometers capable of simulating and measuring a wide-variety of sensors. In addition, features such as high accuracies, preset storage, ramp, step and transfer modes further enhance their versatility.

Features

  • Reads and sources thermocouple signals
  • 0.01°/0.1° display resolution
  • Supports k, j, e and t thermocouples
  • Internal storage for 20 presets
  • 0.01° display resolution
  • 500-hour battery life
  • 500 hour battery life
  • Five (5) digit dual LCD with LED Backlight
  • Meets MIL-prf-28800f class 2
  • Simultaneous Source/Measure
  • Comprehensive real-time statistics: MIN, MAX, AVG, RNG, and STDEV
  • Easy to clean
  • Probe offset function to minimize probe error
  • °F, °C, and mV temperature and voltage units
  • Durable: Meets MIL-PRF-28800F, Class 2 requirements
  • Tilt Stand/Magnet/Hanger

Applications

  • Thermocouple instrument calibration
  • Calibrating thermocouple-based temperature sensors in industrial process loops
  • Field temperature calibration
  • Simulating thermocouple signals to verify temperature transmitters and controllers
  • Thermocouple transmitter calibration
  • Field verification of K, J, E, and T type thermocouple probes
  • Process instrument checking
  • Troubleshooting process readouts using transfer mode to source an offset-corrected mV signal
  • Laboratory calibration
  • Recording temperature stability with real-time MIN/MAX/AVG statistics during calibration

OMEGA CL940A Specifications

Source/measure accuracy ±0.003% [reading] ± 5 µV (18° to 28°C / 64.4° to 82.4°F, CJC error included)
Series CL940A
Resolution 0.01°C up to 999.99°C and 0.1°C at 1000°C or greater
Type thermocouple calibrator
Range -15 mV to 85 mV
Type Industrial handheld thermocouple calibrator
Cold junction error ±0.15°C
Thermocouple types K, J, E, T
Connector type Two (2) Mini-TC Copper
Accuracy ±0.003% reading ±5 μV
Temperature units °C, °F, mV
Resolution 0.01°
Probe zero function Resolution 0.1°C/°F
Battery life 500 hours
Reading rate 3/sec. for readings and TREND indicators
Function Read and source signals
Battery type 3 AA (IEC LR6, ANSI 15) Alkaline
Standard MIL-PRF-28800F Class 2
Battery life 500 hours typical
Range -15 mV to 85 mV
Battery indicator Four (4) stage battery charge indicator
Cold Junction Error ±0.15°C
Display Two (2) rows of five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth
Conformity ITS-90 Types B,E,J,K,N,R,S,T; EN 60584-1 2013 Type C; ASTM E988 Table 3 Type D; ASTM E1751 5.1.1 Type G; DIN 43710 Types L and U; ASTM E1751 5.1.2 Type P
Statistics Minimum reading, Maximum reading, Average reading, Reading range, Standard deviation
Temperature Ranges (CL940A types) K: -382 to 2502°F (-230 to 1372°C) (-382°F to 2502°F); J: -328 to 2192°F (-200 to 1200°C) (-328°F to 2192°F); T: -436 to 752°F (-260 to 400°C) (-436°F to 752°F); E: -400 to 1832°F (-240 to 1000°C) (-400°F to 1832°F)
Display backlight Four (4) LED backlight with 30-second timeout
Connector Type Two (2) Mini-TC Copper
Auto off 20 minute no key pressed Auto Off. Feature can be disabled
Temperature Units °C, °F, mV
Keypad Twelve (12) momentary switches with audible and tactile feedback
Probe Zero Function Resolution 0.1°C/°F
Power cycle configuration retention Instrument retains: Sensor Type, Temperature Unit, Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode
Reading Rate 3/sec. for Readings and TREND indicators
Internal preset storage 20 preset user-determined storage registers, 0-19
Display Two (2) rows of Five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth; 5-DIGIT AUTO-RESOLUTION (0.1/0.01) with backlight and function annunciators
Input current ±50 nA maximum
Display Resolution 0.01° <1000°, .1° ≥ 1000°
Maximum common mode voltage 42 V peak to earth, 1 V p-p between T1 and T2
Display Backlight Four (4) LED Backlight with 30-second timeout
Low resistance load Less than 5 µV change in output with a 100 KΩ resistance
Statistics Minimum Reading, Maximum Reading, Average Reading, Reading Range, Standard Deviation
Operating temp -4° to 131°F (-20° to 55°C)
Auto Off 20 minute no key pressed Auto Off. Feature can be disabled
Storage temp -59.8° to 159.8°F (-51° to 71°C)
Keypad Twelve (12) momentary switches with audible and tactile feedback
Humidity less than 10°C (50°F): Non-condensing
10° to 30°C (50° to 86°F): 5 to 95% RH
30° to 40°C (86° to 104°F): 5 to 85% RH
40° to 55°C (104° to 131°F): 5 to 60% RH
Power Cycle Configuration Retention Retains Sensor Type, Temperature Unit, Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode
Altitude 0 to 15,092 ft (0 to 4600 m)
Internal Preset Storage 20 Preset user-determined storage registers, 0-19
Vibration Random 10-500 Hz, 0.03 g2/Hz
Input Current ±50 nA maximum
Shock 30 g Half Sine
Maximum Common Mode Voltage 42 V peak to earth 1 V p-p between T1 and T2
Drop 4 Drops from 1 m to Concrete
Low Resistance Load Less than 5μV change in output with a 100KΩ resistance
Compliance, electrical CE, MIL-PRF-28800F Class 2
Battery Type 3 AA (IEC LR6, ANSI 15) Alkaline
Compliance, substances RoHS 2 Directive, 2011/65/EU Compliant, REACH
Battery Indicator Four (4) Stage Battery Charge Indicator
Electrical safety IEC-61010
Operating Temp -4 to 131°F (-20 to 55°C)
EMC EN 61326, MIL-PRF-28800F, Class 2
Storage Temp -59.8 to 159.8°F (-51 to 71°C)
ESD IEC 61326 Criterion B
Humidity <50°F (10°C): Non-condensing; 50 to 86°F (10 to 30°C): 5 to 95% RH; 86 to 104°F (30 to 40°C): 5 to 85% RH; 104°F (40°C) to 104 to 131°F (55°C): 5 to 60% RH
Sanitation NSF/ANSI/3-1 14159-2
Altitude 0 to 15,092 ft (0 to 4600 m)
Standards MIL-PRF-28800F, Class 2
Vibration Random 10 – 500 Hz, 0.03 g2/Hz
Included accessories 3 AA Batteries, Quick Start Guide, Tilt Stand/Magnetic, Calibration Report
Shock 30g Half Sine
Conformity ITS-90 Types E, J, K, T
Drop 4 Drops from 3.28' (1 m) to Concrete
Supported thermocouple types K, J, T, E
Compliance, Electrical CE, MIL-PRF-28800F Class 2
Type K range -382° to 2502°F (-230° to 1372°C)
Compliance, Substances RoHS 2 Directive, 2011/65/EU Compliant, REACH
Type J range -328° to 2192°F (-200° to 1200°C)
Electrical Safety IEC-61010
Type T range -436° to 752°F (-260° to 400°C)
EMC EN 61326, MIL-PRF-28800F, Class 2
Type E range -400° to 1832°F (-240° to 1000°C)
ESD IEC 61326 Criterion B
Dimensions 7.6 x 3.3 x 1.1" (193 x 84 x 28 mm)
Sanitation NSF/ANSI/3-1 14159-2
Weight 12.8 oz (362.9 g) including batteries
Included Accessories 3 AA Batteries, Quick Start Guide, Tilt Stand/Magnetic, Calibration Report
Dimensions 7.6 x 3.31 x 1.1" (193 x 84 x 28 mm) (7.6 x 3.3 x 1.1 in)
Weight including Batteries 12.8 oz (362.9 g)

What's included with the OMEGA CL940A

  • Calibrator Thermometer
  • Quick Start Guide
  • Tilt Stand/Magnetic
  • Calibration Report
  • 3 AA Batteries

Ask a question about Omega CL940A Industrial Thermocouple Calibrator, K/J/E/T thermocouples, ±0.003% rdg ±5 µV, 500-hour battery