Made for liquid flow measurement, this turbine flow meter reads from 1 LPM (0.26 GPM) to 15 LPM (3.96 GPM). It connects through 3/8" male NPT threads and provides an amplified square-wave output on an integral 1 m (3.3 ft) cable with ±3% accuracy. Its Trogamid housing with PTFE and graphite bearings carries NSF/ANSI certification, suiting it to potable water and clean liquid metering.
Made for liquid flow measurement, this turbine flow meter reads from 1 LPM (0.26 GPM) to 15 LPM (3.96 GPM). It connects through 3/8" male NPT threads and provides an amplified square-wave output on an integral 1 m (3.3 ft) cable with ±3% accuracy. Its Trogamid housing with PTFE and graphite bearings carries NSF/ANSI certification, suiting it to potable water and clean liquid metering.
| Operating temperature | -4...212°F (-20...100°C) |
| Accuracy | ±3% of reading |
| Repeatability | <0.50% under the same operating conditions |
| Viscosity | up to 16 cSt |
| Filter | 20...40 microns recommended |
| Input power | 5...24 V DC |
| Power consumption | ~8 mA |
| Output (Hz) | NPN sinking open collector |
| Output current | Max. 20 mA |
| Housing | PA12 Trogamid (NSF/ANSI 61 and 372 certified) |
| Turbine | PA12 Ferrite |
| Bearings | Graphite/PTFE |
| Approvals | KTW and W270 approval for drinking water. FDA approved materials. Meets 21 CFR 175.300. |
| Flow range | 0.26...4.0 gpm (1...15 lpm) |
| K-factor | 8300 ppg (2200 ppl) |
| DN | 8 mm |
| Operating pressure | 360 psi (25 bar) |
| Burst pressure | 2900 psi (200 bar) |
| Inlet / outlet ports | 3/8" NPT or G 3/8" (BSPP) |
| End connection | 3/8" NPT |
| Electrical connection | Cable (3 x AWG 24) with free ends, 1 meter long |
| Dimensions | Overall: 2.17" (55 mm) A: 1.18" (30 mm) B: 1.06" (27 mm) C: 0.47" (12 mm) E: 0.47" (12 mm) G: 0.79" (20 mm) |
| Weight | ~0.53 oz (15 g) |