NAVAC SK3TPH1 Smart Refrigerant and Air Side Diagnostics Kit, A2L

Model: SK3TPH1 | UPC: 811245035388

NAVAC SK3TPH1 Smart Refrigerant and Air Side Diagnostics Kit, A2L

Model: SK3TPH1 | UPC: 811245035388

Compatible with the myNAVAC™ App, this smart refrigerant and air side diagnostics kit is an all-in-one solution for HVAC/R professionals. Moreover, each probe (NSH1, NSP1) features a built-in digital display for standalone use, rechargeable lithium batteries, and intuitive controls for seamless operation.

Compatible with the myNAVAC™ App, this smart refrigerant and air side diagnostics kit is an all-in-one solution for HVAC/R professionals. Moreover, each probe (NSH1, NSP1) features a built-in digital display for standalone use, rechargeable lithium batteries, and intuitive controls for seamless operation.

Sale Price $749.00 USD
Regular Price $1049.00 USD
Availability 4 in Stock
Quantity

NAVAC SK3TPH1 Offers

Features

Smart Probes with Digital Display

  • Probes are suitable for standalone use
  • Works wirelessly with myNAVAC App
  • High accuracy sensors
  • Built-in digital screen

NSP1 Bluetooth Pressure Probe

  • Auto VSAT / LSAT calculations thru App
  • Rechargeable lithium battery
  • Easy-to-Switch Knob, suitable for either, High (HP) or Low (LP) Side

NST1 NST2 Bluetooth Temperature Clamps

  • 1-5/8" (42 mm) opening
  • High accuracy thermistor sensor
  • Bluetooth connection with NEXUS Digital Manifold Gauge

NSH1 Bluetooth Psychrometer

  • Detailed psychrometric datapoints
  • Rechargeable lithium battery
  • Easy-to-switch knob, suitable for either Side Supply (SP) or Return (RT)

F1030 1/4" Access Tee connector

  • 1/4" SAE male x 1/4" SAE female with depressor x 1/4" SAE male
  • Includes 1 x core and 1 x cap

Applications

  • Refrigerant diagnostics
  • Air-side analysis
  • System pressure measurement
  • Superheat and subcooling analysis
  • HVAC/R system troubleshooting

NAVAC SK3TPH1 Specifications

NST1, NST2
Temperature Range -40 to 257°F (-40 to 125°C)
Accuracy ±2.3°F (±1.3°C)
Resolution 0.1
Sensor Type Thermistor Pt100
Temperature Units °F,°C
Maximum Tube OD 1-5/8″ (42 mm)
Maximum Bluetooth Range Up to 450′ (150 m)
Display Type TFT
IP Rating IP54
Battery Type 2 x AAA
Weight 0.35 lbs (200 g)
NSP1
Measurement Range -29.0 inHg to 725 psi
Maximum Overload Pressure 1087 psi (7500 kPa)
Accuracy ±0.5% of full range
Resolution 0.01 psi
Sensor Type Ceramic pressure sensor
Bluetooth Range 164' (50 m)
Power Supply Rechargeable 1200 mAh lithium battery
Type-C charging port
Rechargeable Battery Operating Time Screen off: >200 h
Screen on: >40 h
Wireless Frequency 2.4 GHz
Auto Power Off (APO) 2 hours (can be disabled)
Minimum Device Requirement BLE4.0 or above
Android 7.0.0 or above
Apple iOS 12.0 or above
Accessory Carry bag
Weight 0.47 lbs (215 g)
NSH1
Measurement Range Humidity: 0 to 100% RH
Temperature: -40 to 249.8°F (-40°C a 121°C)
Measurement Units °F (Fahrenheit)
°C (Celsius)
% RH (Relative Humidity)
°Ftd (Fahrenheit, dry bulb temperature)
°Ctd (Celsius, dry bulb temperature)
Wet Bulb°F
Wet Bulb°C
Accuracy Humidity:
10 to 90% RH: ±2% RH at 77°F (25°C)
<10% Rhor >90% RH: ±5% RH at 77°F (25°C)

Temperature:
±1.1°F: −4 to 32°F (±0.6°C: -20 to 0°C)
±0.9°F: 32 to 140°F (±0.5°C: 0 to 60°C)
±1.3°F: 140 to 248°F (±0.7°C: 60 to 120°C)
Resolution Humidity: 0.1% RH
Temperature: 0.1°C
Sensor Type Humidity: Capacitive polymer Film
Temperature: Precision thermistor
Response Time 10 seconds
Bluetooth Range  164' (50 m)
Power Supply Rechargeable 1200 mAh lithium battery/
Type-C Charging Port
Rechargeable Battery Operating Time Screen off: >200 h
Screen on: >40 h
Wireless Frequency 2.4 GHz
Auto Power Off (APO) 2 hours (can be disabled)
Flexible Probe Length: 7.9" (200 mm)
Diameter: 0.39" (10 mm)
Minimum Device Requirement BLE4.0 or above
Android 7.0.0 or above
Apple iOS 12.0 or above
Accessory Carry bag
Weight 0.49 lbs (220 g)
F1030
Fit Configuration 1/4″ SAE M x 1/4″ SAE FE x 1/4″ SAE M
Click here for complete specifications on the NAVAC SK3TPH1

What's included with the NAVAC SK3TPH1

  • 2 x NSP1 Bluetooth Pressure Probes
  • 1 x NST1 - Low Side Bluetooth Temperature Clamp
  • 1 x NST2 - High Side Bluetooth Temperature Clamp
  • 2 x NSH1 Bluetooth Psychrometers
  • 2 x F1030 - 1/4" SAE Access Tee Connectors
  • One-Year Warranty

Ask a question about NAVAC SK3TPH1 Smart Refrigerant and Air Side Diagnostics Kit, A2L

Customer Reviews for the NAVAC SK3TPH1

NAVAC SK3TPH1 Offers

Features

Smart Probes with Digital Display

  • Probes are suitable for standalone use
  • Works wirelessly with myNAVAC App
  • High accuracy sensors
  • Built-in digital screen

NSP1 Bluetooth Pressure Probe

  • Auto VSAT / LSAT calculations thru App
  • Rechargeable lithium battery
  • Easy-to-Switch Knob, suitable for either, High (HP) or Low (LP) Side

NST1 NST2 Bluetooth Temperature Clamps

  • 1-5/8" (42 mm) opening
  • High accuracy thermistor sensor
  • Bluetooth connection with NEXUS Digital Manifold Gauge

NSH1 Bluetooth Psychrometer

  • Detailed psychrometric datapoints
  • Rechargeable lithium battery
  • Easy-to-switch knob, suitable for either Side Supply (SP) or Return (RT)

F1030 1/4" Access Tee connector

  • 1/4" SAE male x 1/4" SAE female with depressor x 1/4" SAE male
  • Includes 1 x core and 1 x cap

Applications

  • Refrigerant diagnostics
  • Air-side analysis
  • System pressure measurement
  • Superheat and subcooling analysis
  • HVAC/R system troubleshooting

NAVAC SK3TPH1 Specifications

NST1, NST2
Temperature Range -40 to 257°F (-40 to 125°C)
Accuracy ±2.3°F (±1.3°C)
Resolution 0.1
Sensor Type Thermistor Pt100
Temperature Units °F,°C
Maximum Tube OD 1-5/8″ (42 mm)
Maximum Bluetooth Range Up to 450′ (150 m)
Display Type TFT
IP Rating IP54
Battery Type 2 x AAA
Weight 0.35 lbs (200 g)
NSP1
Measurement Range -29.0 inHg to 725 psi
Maximum Overload Pressure 1087 psi (7500 kPa)
Accuracy ±0.5% of full range
Resolution 0.01 psi
Sensor Type Ceramic pressure sensor
Bluetooth Range 164' (50 m)
Power Supply Rechargeable 1200 mAh lithium battery
Type-C charging port
Rechargeable Battery Operating Time Screen off: >200 h
Screen on: >40 h
Wireless Frequency 2.4 GHz
Auto Power Off (APO) 2 hours (can be disabled)
Minimum Device Requirement BLE4.0 or above
Android 7.0.0 or above
Apple iOS 12.0 or above
Accessory Carry bag
Weight 0.47 lbs (215 g)
NSH1
Measurement Range Humidity: 0 to 100% RH
Temperature: -40 to 249.8°F (-40°C a 121°C)
Measurement Units °F (Fahrenheit)
°C (Celsius)
% RH (Relative Humidity)
°Ftd (Fahrenheit, dry bulb temperature)
°Ctd (Celsius, dry bulb temperature)
Wet Bulb°F
Wet Bulb°C
Accuracy Humidity:
10 to 90% RH: ±2% RH at 77°F (25°C)
<10% Rhor >90% RH: ±5% RH at 77°F (25°C)

Temperature:
±1.1°F: −4 to 32°F (±0.6°C: -20 to 0°C)
±0.9°F: 32 to 140°F (±0.5°C: 0 to 60°C)
±1.3°F: 140 to 248°F (±0.7°C: 60 to 120°C)
Resolution Humidity: 0.1% RH
Temperature: 0.1°C
Sensor Type Humidity: Capacitive polymer Film
Temperature: Precision thermistor
Response Time 10 seconds
Bluetooth Range  164' (50 m)
Power Supply Rechargeable 1200 mAh lithium battery/
Type-C Charging Port
Rechargeable Battery Operating Time Screen off: >200 h
Screen on: >40 h
Wireless Frequency 2.4 GHz
Auto Power Off (APO) 2 hours (can be disabled)
Flexible Probe Length: 7.9" (200 mm)
Diameter: 0.39" (10 mm)
Minimum Device Requirement BLE4.0 or above
Android 7.0.0 or above
Apple iOS 12.0 or above
Accessory Carry bag
Weight 0.49 lbs (220 g)
F1030
Fit Configuration 1/4″ SAE M x 1/4″ SAE FE x 1/4″ SAE M
Click here for complete specifications on the NAVAC SK3TPH1

What's included with the NAVAC SK3TPH1

  • 2 x NSP1 Bluetooth Pressure Probes
  • 1 x NST1 - Low Side Bluetooth Temperature Clamp
  • 1 x NST2 - High Side Bluetooth Temperature Clamp
  • 2 x NSH1 Bluetooth Psychrometers
  • 2 x F1030 - 1/4" SAE Access Tee Connectors
  • One-Year Warranty

Ask a question about NAVAC SK3TPH1 Smart Refrigerant and Air Side Diagnostics Kit, A2L