NAVAC NMA1 Smart Combustion Analyzer

Model: NMA1 | UPC: 811245035692

NAVAC NMA1 Smart Combustion Analyzer

Model: NMA1 | UPC: 811245035692

Featuring smart App connectivity with an intuitive, advanced user interface, this combustion analyzer also pairs with myNAVAC™ and measureQuick® via Bluetooth for wireless monitoring, data tracking, and professional reporting. Additionally, it offers a 5" color HD touchscreen and built-in differential pressure and draft measurement.

Featuring smart App connectivity with an intuitive, advanced user interface, this combustion analyzer also pairs with myNAVAC™ and measureQuick® via Bluetooth for wireless monitoring, data tracking, and professional reporting. Additionally, it offers a 5" color HD touchscreen and built-in differential pressure and draft measurement.

Sale Price $1799.00 USD
Regular Price $2519.00 USD
Availability 2 to 3 Weeks
Quantity

Recommended Accessories


NAVAC NMA1 Offers

Features

  • Intuitive and advanced user interface
  • Large HD touchscreen
  • Hands-free magnetic mount
  • Detachable soft tube

Complete combustion analysis in one smart tool

Large HD Touchscreen

  • 5" color touchscreen
  • Smartphone-like operation
  • Easy reading in any lighting

Built-In Pressure and Draft

  • Onboard differential pressure (±40 inWC)
  • No separate manometer needed

Smart App Connectivity

  • Works with myNAVAC™ and measureQuick®
  • Bluetooth up to 164' (50 m)
  • Hands-free wireless monitoring

Professional Reporting

  • Up to 1000 stored records
  • Data annotation and job tracking
  • NPR1 wireless printer (sold separately)

Full Combustion Analysis

  • O2, CO and flue temp sensing
  • Calculates CO2, efficiency, excess air
  • Ambient CO with alarm levels

Field-Ready Design

  • 6+ hr battery, USB Type-C charging
  • Lightweight, easy-to-grip
  • One tool for all fuels and systems

Applications

  • Combustion analysis for boilers, furnaces, and heating systems
  • HVAC/R system testing and maintenance to optimize combustion efficiency and performance
  • Flue gas monitoring for detecting emissions and verifying safe equipment operation

NAVAC NMA1 Specifications

Combustion Analyzer
Bluetooth Range ≤164' (≤50 m)
Pump Flow Rate >0.088 gal/min (400 mL/min)
Screen 5-inch
720*1280 touch screen
Environmental Conditions Operating temperature: 23 to 113°F (-5 to 45°C)
Operating humidity: <90% RH
Storage temperature: −4 to 122°F (-20 to 50°C)
Power Type-C charging
Battery Life 6 hours (pump running 100% of the time)
Charging Time <3 hours
Dimensions 9.25 x 4.33 x 2.32" (235 x 110 x 58.9 mm)
Case: 20.94 x 13.50 x 5.24" (532 x 343 x 133 mm)
Weight Device: 1.65 lbs (749 g)
Measuring gun: 1.21 lbs (550 g)
Performance Analysis
Calculated CO2 Range: 0 to CO2maximum vol%
Accuracy: 0.1 vol%
Resolution: ±0.3 vol%
Response time: <40 seconds
Combustion Efficiency Range: 0 to 100%
Accuracy: Calculated
Resolution: 0.10%
Excess Air Range: 0 to 999%
Accuracy: Calculated
Resolution: 0.10%
Perte de gaz de combustion (qA) Range: 0 to 100%
Accuracy: Calculated
Resolution: 0.10%
O2 Sensor Range: 0 to 25 vol%
Accuracy: 0.1 vol%
Resolution: ±0.3 vol%
Response time: <30 seconds
CO Sensor Range:
0 to 4000 ppm

Accuracy:
±10 ppm: 0 to 200 ppm
±5% reading: 201 to 2000 ppm
±10% reading: 2001 to 4000 ppm
Overload: 10000 ppm carbon monoxide

Resolution: 1 ppm

Response time: <90 seconds
Differential Pressure Sensor Range:
0 to ±40 inWC

Accuracy:
±0.2 inWC: 0 to ±20 inWC
±1% reading: ±20.1 to 40.0 inWC
Overload: 11.6 psig (321 inWC)

Resolution: 0.01 inWC

Response time: <10 seconds
Flue Gas Temperature Sensor Range:
32 to 1112°F (0 to 600°C)

Accuracy:
±2.5°F: 32 to 212°F
±3.6°F or 1.5% reading: 213 to 1112°F
±1.4°C: 0 to 100°C
±2.0°C or 1.5% reading: 101 to 600°C

Resolution: 0.1°F (0.1°C)

Response time: <30 seconds
Ambient Temperature Sensor (one-time air temperature) Range: -4 to 248°F (-20 to 120°C)
Accuracy: ±3.6°F (±2.0°C)
Resolution: 0.1°F (0.1°C)
Response time: <30 seconds
Click here for complete specifications on the NAVAC NMA1

What's included with the NAVAC NMA1

  • Combustion Analyzer
  • Probe Gun with Water Trap Assembly
  • O-Ring Seal
  • Dust Filter Element
  • Tube Connector
  • Adapter Hose
  • Silicone Hose
  • Silicone Hose Connector
  • 5' C-to-C Cable
  • Carrying Case
  • Inspection Report
  • Certificate of Conformity (CoC)
  • Manual Card
  • Two-Year Device Warranty
  • Four-Year Sensor Warranty

Click on a category to view a selection of compatible accessories with the NAVAC NMA1 Smart Combustion Analyzer.

NAVAC NPR1 Printer for NMA1 combustion analyzer, wireless NPR1
Designed for use with the NMA1 combustion analyzer, this thermal printer features wireless connectivity. Furthermore, it comes with one roll of thermal paper.




Ask a question about NAVAC NMA1 Smart Combustion Analyzer

Customer Reviews for the NAVAC NMA1

NAVAC NMA1 Offers

Features

  • Intuitive and advanced user interface
  • Large HD touchscreen
  • Hands-free magnetic mount
  • Detachable soft tube

Complete combustion analysis in one smart tool

Large HD Touchscreen

  • 5" color touchscreen
  • Smartphone-like operation
  • Easy reading in any lighting

Built-In Pressure and Draft

  • Onboard differential pressure (±40 inWC)
  • No separate manometer needed

Smart App Connectivity

  • Works with myNAVAC™ and measureQuick®
  • Bluetooth up to 164' (50 m)
  • Hands-free wireless monitoring

Professional Reporting

  • Up to 1000 stored records
  • Data annotation and job tracking
  • NPR1 wireless printer (sold separately)

Full Combustion Analysis

  • O2, CO and flue temp sensing
  • Calculates CO2, efficiency, excess air
  • Ambient CO with alarm levels

Field-Ready Design

  • 6+ hr battery, USB Type-C charging
  • Lightweight, easy-to-grip
  • One tool for all fuels and systems

Applications

  • Combustion analysis for boilers, furnaces, and heating systems
  • HVAC/R system testing and maintenance to optimize combustion efficiency and performance
  • Flue gas monitoring for detecting emissions and verifying safe equipment operation

NAVAC NMA1 Specifications

Combustion Analyzer
Bluetooth Range ≤164' (≤50 m)
Pump Flow Rate >0.088 gal/min (400 mL/min)
Screen 5-inch
720*1280 touch screen
Environmental Conditions Operating temperature: 23 to 113°F (-5 to 45°C)
Operating humidity: <90% RH
Storage temperature: −4 to 122°F (-20 to 50°C)
Power Type-C charging
Battery Life 6 hours (pump running 100% of the time)
Charging Time <3 hours
Dimensions 9.25 x 4.33 x 2.32" (235 x 110 x 58.9 mm)
Case: 20.94 x 13.50 x 5.24" (532 x 343 x 133 mm)
Weight Device: 1.65 lbs (749 g)
Measuring gun: 1.21 lbs (550 g)
Performance Analysis
Calculated CO2 Range: 0 to CO2maximum vol%
Accuracy: 0.1 vol%
Resolution: ±0.3 vol%
Response time: <40 seconds
Combustion Efficiency Range: 0 to 100%
Accuracy: Calculated
Resolution: 0.10%
Excess Air Range: 0 to 999%
Accuracy: Calculated
Resolution: 0.10%
Perte de gaz de combustion (qA) Range: 0 to 100%
Accuracy: Calculated
Resolution: 0.10%
O2 Sensor Range: 0 to 25 vol%
Accuracy: 0.1 vol%
Resolution: ±0.3 vol%
Response time: <30 seconds
CO Sensor Range:
0 to 4000 ppm

Accuracy:
±10 ppm: 0 to 200 ppm
±5% reading: 201 to 2000 ppm
±10% reading: 2001 to 4000 ppm
Overload: 10000 ppm carbon monoxide

Resolution: 1 ppm

Response time: <90 seconds
Differential Pressure Sensor Range:
0 to ±40 inWC

Accuracy:
±0.2 inWC: 0 to ±20 inWC
±1% reading: ±20.1 to 40.0 inWC
Overload: 11.6 psig (321 inWC)

Resolution: 0.01 inWC

Response time: <10 seconds
Flue Gas Temperature Sensor Range:
32 to 1112°F (0 to 600°C)

Accuracy:
±2.5°F: 32 to 212°F
±3.6°F or 1.5% reading: 213 to 1112°F
±1.4°C: 0 to 100°C
±2.0°C or 1.5% reading: 101 to 600°C

Resolution: 0.1°F (0.1°C)

Response time: <30 seconds
Ambient Temperature Sensor (one-time air temperature) Range: -4 to 248°F (-20 to 120°C)
Accuracy: ±3.6°F (±2.0°C)
Resolution: 0.1°F (0.1°C)
Response time: <30 seconds
Click here for complete specifications on the NAVAC NMA1

What's included with the NAVAC NMA1

  • Combustion Analyzer
  • Probe Gun with Water Trap Assembly
  • O-Ring Seal
  • Dust Filter Element
  • Tube Connector
  • Adapter Hose
  • Silicone Hose
  • Silicone Hose Connector
  • 5' C-to-C Cable
  • Carrying Case
  • Inspection Report
  • Certificate of Conformity (CoC)
  • Manual Card
  • Two-Year Device Warranty
  • Four-Year Sensor Warranty

Click on a category to view a selection of compatible accessories with the NAVAC NMA1 Smart Combustion Analyzer.

NAVAC NPR1 Printer for NMA1 combustion analyzer, wireless NPR1
Designed for use with the NMA1 combustion analyzer, this thermal printer features wireless connectivity. Furthermore, it comes with one roll of thermal paper.




Ask a question about NAVAC NMA1 Smart Combustion Analyzer

Customer Reviews for the NAVAC NMA1

More NAVAC Products

NAVAC Summer Promotion