Produces 3-step/5-step, this linear gauge counter features a simple display, multi-step Go/No Go judgment and output, BCD output, and open collector. Additionally, this counter has a differential square-wave applicable input and is compatible with the LGF, LGK, LGB, LGM, LGH, LG, and LGE linear gauges.
Produces 3-step/5-step, this linear gauge counter features a simple display, multi-step Go/No Go judgment and output, BCD output, and open collector. Additionally, this counter has a differential square-wave applicable input and is compatible with the LGF, LGK, LGB, LGM, LGH, LG, and LGE linear gauges.
Features
Applicable Gauge Head | LGE, LGF, LGK, LGB, LGM, LG, LGH (Not compatible with LGH110, reference point or sine wave models) |
Number of Gauge Inputs | 1 |
Quantizing Error | ±1 count |
Maximum Input Frequency | 1.25 MHz, response speed depends on gauge specification |
Resolution | 0.01 mm (±9999.99 mm)/0.0005" (±99.9995")/0.001" (±999.999") 0.005mm (±9999.995mm)/0.00005" (±9.99995")/0.0001" (±99.999") 0.001mm (±999.999mm)/0.00005" (±9.99995")/0.0001"(±99.999") 0.0005mm (±99.9995mm)/0.000005" (±.999995")/0.00001" (±9.99999") 0.0001mm (±99.9999mm)/0.000005" (±.999995")/0.00001" (±9.99999") |
Display | Sign plus 6 digits (Green LED) |
Tolerance Judgment | Display: LED display (3 steps: Amber, green, red/5 steps: amber, amber flashing, green, red flashing, red) L1 to L5 (Open-collector/switchover between L1 to L5 and BCD output with parameter) |
Control | Output: Normal operation signal (NOM): open-collector Input: Pre setting, display hold, peak value clear, tolerance judgment BANK switch |
BCD Output | Open-collector / Switchover between 6-digit (positive/negative-true logic) and tolerance judgment output with parameter |
Rating | Power supply voltage: 12 to 24 V DC Power consumption: 6 W or less (500 mA maximum) Ensure at least 1 A is available per unit |
Temperature Range | Operating: 0 to 40°C (RH 20 to 80%, no condensation) Storage: –10 to 50°C (RH 20 to 80%, no condensation) |
Applicable Input | Differential square-wave |
Number of Gauge Inputs | 1 |
Dimensions | 3.78 x 1.89 x 6.14" (96 × 48 × 156 mm) |
Weight | 0.88 lbs (400 g) |
Applicable Gauge Head | LGE, LGF, LGK, LGB, LGM, LG, LGH (Not compatible with LGH110, reference point or sine wave models) |
Number of Gauge Inputs | 1 |
Quantizing Error | ±1 count |
Maximum Input Frequency | 1.25 MHz, response speed depends on gauge specification |
Resolution | 0.01 mm (±9999.99 mm)/0.0005" (±99.9995")/0.001" (±999.999") 0.005mm (±9999.995mm)/0.00005" (±9.99995")/0.0001" (±99.999") 0.001mm (±999.999mm)/0.00005" (±9.99995")/0.0001"(±99.999") 0.0005mm (±99.9995mm)/0.000005" (±.999995")/0.00001" (±9.99999") 0.0001mm (±99.9999mm)/0.000005" (±.999995")/0.00001" (±9.99999") |
Display | Sign plus 6 digits (Green LED) |
Tolerance Judgment | Display: LED display (3 steps: Amber, green, red/5 steps: amber, amber flashing, green, red flashing, red) L1 to L5 (Open-collector/switchover between L1 to L5 and BCD output with parameter) |
Control | Output: Normal operation signal (NOM): open-collector Input: Pre setting, display hold, peak value clear, tolerance judgment BANK switch |
BCD Output | Open-collector / Switchover between 6-digit (positive/negative-true logic) and tolerance judgment output with parameter |
Rating | Power supply voltage: 12 to 24 V DC Power consumption: 6 W or less (500 mA maximum) Ensure at least 1 A is available per unit |
Temperature Range | Operating: 0 to 40°C (RH 20 to 80%, no condensation) Storage: –10 to 50°C (RH 20 to 80%, no condensation) |
Applicable Input | Differential square-wave |
Number of Gauge Inputs | 1 |
Dimensions | 3.78 x 1.89 x 6.14" (96 × 48 × 156 mm) |
Weight | 0.88 lbs (400 g) |