Megger MIT410/TC2 Insulation Resistance and Continuity Tester, LG2

Model: 1006-731 | Order No: MIT410/TC2

Megger MIT410/TC2 Insulation Resistance and Continuity Tester, LG2

Model: 1006-731 | Order No: MIT410/TC2

Designed specifically for use within the telecommunications industry. The instrument allows the user to determine the condition of the insulation of the twisted copper cable pair, which could cause problems for services such as voice, video, and data or VOIP.

Designed specifically for use within the telecommunications industry. The instrument allows the user to determine the condition of the insulation of the twisted copper cable pair, which could cause problems for services such as voice, video, and data or VOIP.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Megger MIT410/TC3 Insulation Resistance & Continuity Tester, LG1-

Megger MIT410/TC3 Insulation Resistance & Continuity Tester, LG1

Model: MIT410/TC3 | Order No: 1006-730

Designed specifically for use within the telecommunications industry. The instrument allows the user to determine the condition of the insulation of the twisted copper cable pair, which could cause problems for services such as voice, video, and data or VOIP.


Megger 1006-731 Offers

Features

  • Insulation testing up to 500 V and 100 G-ohms
  • Patented analog arc and dual digital display

Applications

The units provide for all metallic and resistive fault testing of the customers' inside premise wiring including:

  • Shorts
  • Grounds
  • Cross voltage
  • Voltage measurements (both AC and DC) to determine proper voltage levels for line and signaling voltages

By applying a test voltage, the meters will measure the leakage current through the insulation and give the results in ohms. The results can then be reviewed to determine if the premise wire or cable pair cab be used for voice grade or voice/video/data services according to the following industry standards:

  • Readings greater than 100 megohms indicate good insulation
  • Readings between 100 megohms and 90 megohms indicate marginal insulation
  • Readings below 90 megohms indicate bad insulation and further testing is required before the service cab be installed

In addition to the insulation resistance test, the meters allow the technician to conduct continuity tests throughout the customer's premise. Simply place a shunt strap at the location of the modem, then with the meter go to each outlet to test for continuity using the audible alert feature on the meter to determine correct wiring configurations. This feature would replace the need for a tone generator and amplifier.

Megger 1006-731 Specifications

Insulation Nominal Test Voltages 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation resistance range 200 GΩ
Analog range 1 GΩ full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on Load 1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max.
EN61557 Operating range 0.10 MΩ to 1.00 GΩ
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used
Battery life 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Weight 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Click here for complete specifications on the Megger 1006-731

What's included with the Megger 1006-731

  • Insulation Resistance and Continuity Tester
  • Carry Case and Strap
  • Bed of Nails Lead Set
  • Language Group LG2 - English
  • Quick-Start Guide
  • User Guide
  • Battery 1.5V Alkaline AA
  • Certificate of Calibration
  • Holster and Stand
  • Download Manager Software

Click on a category to view a selection of compatible accessories with the Megger MIT410/TC2 Insulation Resistance and Continuity Tester, LG2.

Megger 1007-169 Hard Carrying Case 1007-169
For use with MIT400 Series of CAT IV Insulation Testers.




Megger 1007-160 Test and Carry Pouch 1007-160
For use with the MIT400 Series.




Megger 1007-887 Test and Carry Pouch 1007-887
For use with the MIT400/2 Series.




Megger 1007-464 Mains Charger Kit, MIT400/2 Series 1007-464
Battery charger for MIT410/2, 430/2, 485/2 And 2500 Insulation Testers.




Megger 1007-157 SP5 Remote Switch Probe, CATIV, 600V 1007-157
For use with MIT400/2 Series of Insulation Testers.




Ask a question about Megger MIT410/TC2 Insulation Resistance and Continuity Tester, LG2

Customer Reviews for the Megger 1006-731

Megger 1006-731 Offers

Features

  • Insulation testing up to 500 V and 100 G-ohms
  • Patented analog arc and dual digital display

Applications

The units provide for all metallic and resistive fault testing of the customers' inside premise wiring including:

  • Shorts
  • Grounds
  • Cross voltage
  • Voltage measurements (both AC and DC) to determine proper voltage levels for line and signaling voltages

By applying a test voltage, the meters will measure the leakage current through the insulation and give the results in ohms. The results can then be reviewed to determine if the premise wire or cable pair cab be used for voice grade or voice/video/data services according to the following industry standards:

  • Readings greater than 100 megohms indicate good insulation
  • Readings between 100 megohms and 90 megohms indicate marginal insulation
  • Readings below 90 megohms indicate bad insulation and further testing is required before the service cab be installed

In addition to the insulation resistance test, the meters allow the technician to conduct continuity tests throughout the customer's premise. Simply place a shunt strap at the location of the modem, then with the meter go to each outlet to test for continuity using the audible alert feature on the meter to determine correct wiring configurations. This feature would replace the need for a tone generator and amplifier.

Megger 1006-731 Specifications

Insulation Nominal Test Voltages 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation resistance range 200 GΩ
Analog range 1 GΩ full scale
Short Circuit Current 2 mA +0% -50%
Terminal voltage -0% +20% ±1 V
Test Current on Load 1 mA at min. pass value of insulation specified in BS7671, HD384 and IEC364, 2 mA max.
EN61557 Operating range 0.10 MΩ to 1.00 GΩ
Leakage Current 10% ±3 digits
Voltage display 3% ±3 digits ±0.5% of rated voltage
Power Supply 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used
Battery life 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
Dimensions 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.)
Weight 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot
Click here for complete specifications on the Megger 1006-731

What's included with the Megger 1006-731

  • Insulation Resistance and Continuity Tester
  • Carry Case and Strap
  • Bed of Nails Lead Set
  • Language Group LG2 - English
  • Quick-Start Guide
  • User Guide
  • Battery 1.5V Alkaline AA
  • Certificate of Calibration
  • Holster and Stand
  • Download Manager Software

Click on a category to view a selection of compatible accessories with the Megger MIT410/TC2 Insulation Resistance and Continuity Tester, LG2.

Megger 1007-169 Hard Carrying Case 1007-169
For use with MIT400 Series of CAT IV Insulation Testers.




Megger 1007-160 Test and Carry Pouch 1007-160
For use with the MIT400 Series.




Megger 1007-887 Test and Carry Pouch 1007-887
For use with the MIT400/2 Series.




Megger 1007-464 Mains Charger Kit, MIT400/2 Series 1007-464
Battery charger for MIT410/2, 430/2, 485/2 And 2500 Insulation Testers.




Megger 1007-157 SP5 Remote Switch Probe, CATIV, 600V 1007-157
For use with MIT400/2 Series of Insulation Testers.




Ask a question about Megger MIT410/TC2 Insulation Resistance and Continuity Tester, LG2

Customer Reviews for the Megger 1006-731

More Megger Products